Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Chinese Journal of Medical Instrumentation ; (6): 87-90, 2009.
Artigo em Chinês | WPRIM | ID: wpr-329369

RESUMO

A new adaptively hybrid filtering algorithm is proposed to reduce the artifacts caused by metal in CT image. Firstly, the method is used to preprocess the projection data of metal region and is reconstruct by filtered back projection (FBP) method. Then the expectation maximization algorithm (EM) is performed on the iterative original metal project data. Finally, a compensating procedure is applied to the reconstructed metal region. The simulation result has demonstrated that the proposed algorithm can remove the metal artifacts and keep the structure information of metal object effectively. It ensures that the tissues around the metal will not be distorted. The method is also computational efficient and effective for the CT images which contains several metal objects.


Assuntos
Algoritmos , Artefatos , Metais , Tomografia Computadorizada por Raios X , Métodos
2.
Chinese Journal of Medical Instrumentation ; (6): 188-192, 2009.
Artigo em Chinês | WPRIM | ID: wpr-329346

RESUMO

According to the features of the open permanent MRI system, this paper designs the gradient magnetic field, in which the designed parameters are optimized. The simulation experiments demonstrate the effectiveness of the algorithm.


Assuntos
Algoritmos , Desenho de Equipamento , Campos Magnéticos , Imageamento por Ressonância Magnética
3.
Chinese Journal of Medical Instrumentation ; (6): 247-250, 2009.
Artigo em Chinês | WPRIM | ID: wpr-329331

RESUMO

A novel DR image denoising algorithm based on Laplace-Impact mixture model in dual-tree complex wavelet domain is proposed in this paper. It uses local variance to build probability density function of Laplace-Impact model fitted to the distribution of high-frequency subband coefficients well. Within Laplace-Impact framework, this paper describes a novel method for image denoising based on designing minimum mean squared error (MMSE) estimators, which relies on strong correlation between amplitudes of nearby coefficients. The experimental results show that the algorithm proposed in this paper outperforms several state-of-art denoising methods such as Bayes least squared Gaussian scale mixture and Laplace prior.


Assuntos
Algoritmos , Modelos Estatísticos , Intensificação de Imagem Radiográfica , Métodos
4.
Chinese Journal of Medical Instrumentation ; (6): 175-178, 2008.
Artigo em Chinês | WPRIM | ID: wpr-309620

RESUMO

Combining the speed of two-dimensional detection with the precision of three-dimensional detection, an automatic algorithm based on high resolution CT images is proposed to identify nodules in this paper. Nodule candidates are extracted by a two-dimensional convergence index (CI) filter, then a three-dimensional Hessian matrix detection filter is introduced to reduce false positive lung nodules, Experiments show that the algorithm is effective with a sensitivity of 90% and the false positive lung nodules per slice is 0.33.


Assuntos
Humanos , Algoritmos , Reações Falso-Positivas , Sensibilidade e Especificidade , Nódulo Pulmonar Solitário , Diagnóstico por Imagem , Tomografia Computadorizada por Raios X , Métodos
5.
Chinese Journal of Medical Instrumentation ; (6): 271-274, 2008.
Artigo em Chinês | WPRIM | ID: wpr-309598

RESUMO

In the design of RF receiver of the digital MRI spectrometer console, a digital demodulation and filtering algorithm is presented in this thesis. The MR signals are firstly converted to digital signals by the A/D converter, and then quadrature-demodulated from high frequency carrier wave. The CIC filter, half-band filter and linear phase FIR filter are designed to process the cascaded filtering and decimation of the demodulated signals. This method achieves a satisfying processing speed and filtering effect, and also reduces the data size obviously. The experiment based on the permanent magnetism resonance imaging system proves its effectiveness and practicability.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Métodos , Ondas de Rádio , Processamento de Sinais Assistido por Computador , Software
6.
Chinese Journal of Medical Instrumentation ; (6): 185-188, 2007.
Artigo em Chinês | WPRIM | ID: wpr-323287

RESUMO

A spectrometer is one of the most important parts in a Magnetic Resonance Imaging (MRI) system. This paper describes the design of a digital MRI spectrometer. It is constructed on a PXI platform with several data acquisition boards and a high-resolution timing board. All functions of a MRI spectrometer are realized by the specially- designed software. The software architecture and its implementing details are discussed and experimental results are introduced.


Assuntos
Desenho de Equipamento , Imageamento por Ressonância Magnética , Métodos , Processamento de Sinais Assistido por Computador , Design de Software
7.
Chinese Journal of Medical Instrumentation ; (6): 22-25, 2007.
Artigo em Chinês | WPRIM | ID: wpr-355346

RESUMO

This paper presents a simulation method to study and improve the technology of designing magnets. With the finite element method, it analyzes the magnetic field distribution of the magnet model constructed by CAD software. Based on the distribution characteristics of magnetic field, the redundancy parts of the magnet configuration are removed accurately. The experiment results show that this method can significantly lighten the magnet.


Assuntos
Simulação por Computador , Análise de Elementos Finitos , Imageamento por Ressonância Magnética , Métodos , Magnetismo , Software
8.
Chinese Journal of Medical Instrumentation ; (6): 176-179, 2006.
Artigo em Chinês | WPRIM | ID: wpr-355422

RESUMO

Based on the theory of magnet circuits, the paper introduces the process of designing MRI (Magnetic Resonance Imaging) permanent magnet. The measurement of magnet properties is improved by simulation technology. In order to increase the magnetic field homogeneity. We have designed a shim-loop and a trapeziform shim-board to optimize the magnetic field distribution. The results of both simulation analysis and experiments show that the innovative design improves magnetic field properties significantly and the magnet structure accords with the technology requirements.


Assuntos
Humanos , Algoritmos , Simulação por Computador , Campos Eletromagnéticos , Desenho de Equipamento , Imageamento por Ressonância Magnética , Métodos , Magnetismo
9.
Chinese Journal of Medical Instrumentation ; (6): 375-329, 2006.
Artigo em Chinês | WPRIM | ID: wpr-355374

RESUMO

The design of PACS image workstation based on DICOM3.0 is introduced in the paper, then the designing method of the PACS image browser based on the control system theory is presented,focusing on two main units:DICOM analyzer and the information mapping transformer.


Assuntos
Apresentação de Dados , Desenho de Equipamento , Microcomputadores , Sistemas de Informação em Radiologia , Design de Software , Interface Usuário-Computador
10.
Chinese Journal of Medical Instrumentation ; (6): 11-14, 2006.
Artigo em Chinês | WPRIM | ID: wpr-232901

RESUMO

A wavelet threshold denoising algorithm for CR images is put forward here . A noised CR image is decomposed into wavelet coefficients, which are processed by the algorithm, and the denoised CR image is reconstructed based on the processed coefficients. Examples are too presented to demonstrate the efficiency of the algorithm on denoising and, maintaining the detail of the CR images.


Assuntos
Algoritmos , Intensificação de Imagem Radiográfica , Métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Métodos , Radiografia , Métodos , Processamento de Sinais Assistido por Computador
11.
Chinese Journal of Medical Instrumentation ; (6): 111-113, 2006.
Artigo em Chinês | WPRIM | ID: wpr-232879

RESUMO

A proposal is presented to improve the original complicated control of the exposure parameters in the direct radiography system (DR). The interface circuitry of the high-voltage generator is redesigned using RS-232 serial COM port. The data and signals are transmitted between the personal computer and the high-voltage generator in the serial mode. A program package is designed to realize the control of the exposure parameters of the high-voltage generator in DR on the PC machine. Experiment results have shown that the proposed console operates steadily and it is capable of providing a more convenient operation console for the direct radiography system.


Assuntos
Humanos , Computadores , Desenho de Equipamento , Microcomputadores , Intensificação de Imagem Radiográfica , Métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Métodos , Radiografia , Métodos , Software , Interface Usuário-Computador
12.
Chinese Journal of Medical Instrumentation ; (6): 410-413, 2005.
Artigo em Chinês | WPRIM | ID: wpr-232920

RESUMO

Imaging objects are spatially encoded by gradient magnetic fields in magnetic resonance imaging systems. The eddy current caused by rapid switches of gradient fields will result in artifacts in the images. A method of eddy current compensation based on pre-emphasis of gradient current is presented in this thesis. The compensation parameters are acquired rapidly utilizing Faraday's induction theorem and data fitting method. The experiments prove that the method is efficient for reduction of the debugging time and for the improvement of the image quality.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Métodos
13.
Chinese Journal of Medical Instrumentation ; (6): 30-32, 2002.
Artigo em Chinês | WPRIM | ID: wpr-241071

RESUMO

This paper describes the design of the printing output function for a multi-parameter patient monitor by using the graphic plot function of a Laser Printer. The ECG data are preprocessed with a notch filter and interpolation algorithm. A logical page is constructed in the extended memory for virtual page printing. This monitor is able to output a satisfied printing with ECG waveforms of high quality.


Assuntos
Humanos , Processamento Eletrônico de Dados , Métodos , Gráficos por Computador , Equipamentos para Diagnóstico , Eletrocardiografia Ambulatorial , Métodos , Desenho de Equipamento , Lasers , Impressão , Métodos , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA