Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Arch. cardiol. Méx ; 93(4): 391-397, Oct.-Dec. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1527715

RESUMO

Abstract Objective: The objectives of this study were to evaluate an automated device for ventilatory support based on AMBU manufactured in March 2020. Methods: The ESSI-1 INC was evaluated through pulmonary mechanics and physiology parameters through compensatory spirometer tests (TISSOTs), and an artificial lung Model5600i Dual Adult PNEU VIEW SYSTEM; it was also compared to the anesthetic ventilatory support equipment (AEONMED 7500) in porcine models, measuring ventilatory, hemodynamic and gasometric parameters. Results: This equipment (ESSI-1 INC) was successfully tested by mechanical and biological models, such as pigs in which its performance was evaluated in terms of variability of tidal volume, ventilation frequency, and I/E relationship versus the manual performance of two medical interns. All the results turned out as expected and were satisfactory. Conclusions: It is safe and effective equipment and should be tested and used in diverse clinical conditions to standardize the ventilatory safety and care of patients who require it.


Resumen Objetivo: Evaluar un dispositivo automatizado para la asistencia ventilatoria basado en un AMBU manufacturado en Marzo del 2020. Métodos: El ESSI-1 INC fue evaluado por medio de parámetros fisiológicos y mecánica pulmonar a través de pruebas de espirómetro compensatorios (TISSOT); pulmón artificial (Modelo 5600i Dual Adult PNEU VIEW SYSTEM); así como su desempeño comparado a la máquina de anestesia (AEONMED 7500) en modelos porcinos, midiendo criterios ventilatorios, hemodinámicos y gasométricos. Resultados: Este equipo (ESSI-1 INC) fue exitosamente probado por modelos mecánicos y biológicos, tales como cerdos donde su desempeño fue evaluado en términos de la variabilidad del volumen tidal, frecuencia ventilatoria, y relación I/E versus el desempeño manual de dos médicos. Todos los resultados finalizaron como se esperaba de forma satisfactoria. Conclusiones: Es un equipo seguro y efectivo, el cual debería ser probado y usado en distintas condiciones clínicas para estandarizar la seguridad ventilatoria y cuidado de pacientes que lo requieran.

2.
Med. crít. (Col. Mex. Med. Crít.) ; 35(2): 106-109, Mar.-Apr. 2021. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1375843

RESUMO

Resumen: La enfermad por el virus de SARS-CoV-2 o COVID-19 tiene un alto índice de contagio y transmisibilidad que sobrepasa los sistemas de salud en el mundo. En México se cuentan 1,771,740 casos positivos, 150,273 defunciones y 204,070 contagios, de esas defunciones 2,687 corresponden al personal de salud. La intubación orotraqueal representa uno de los eventos con mayor riesgo de contagio, es por ello que es imperativo el uso de equipo de protección personal así como de distintas acciones a tomar durante la intubación orotraqueal por parte del equipo.


Abstract: The disease caused by the SARS-CoV-2 or COVID-19 virus has a high rate of contagion and transmissibility, surpassing the health systems in the world. In Mexico there are 1'771,740 positive cases, 150,273 deaths, 204,070 infections, and 2,687 of these deaths represent health personnel. Orotracheal intubation represents one of the events with the highest risk of contagion, which is why the use of personal protective equipment is imperative, as well as different attitudes to be taken during orotracheal intubation by the team.


Resumo: A doença causada pelo vírus SARS-CoV-2 ou COVID-19 apresenta alto índice de contágio e transmissibilidade, superando os sistemas de saúde em todo o mundo. No México, há 1.771,740 casos positivos, 150,273 mortes, 204,070 infecções e 2,687 dessas mortes representam pessoal de saúde. A intubação orotraqueal representa um dos eventos de maior risco de contágio, por isso o uso de equipamentos de proteção individual é imprescindível, assim como as diferentes atitudes a serem tomadas durante a intubação orotraqueal pela equipe.

3.
Rev. mex. anestesiol ; 43(2): 145-150, abr.-jun. 2020. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1347703

RESUMO

Resumen: La pandemia COVID-19 nos ha obligado a replantearnos la manera en la que practicamos algunos aspectos de la medicina. La reanimación cardiopulmonar es una práctica que genera partículas en aerosol provenientes de la vía aérea, lo cual incrementa el riesgo de contagio por SARS-CoV-2. En esta revisión se consultan las recomendaciones internacionales sobre el tema, se definen momentos de alto riesgo y se establecen recomendaciones sobre compresiones, ventilación, terapia eléctrica e incluso farmacológica en pacientes con paro cardíaco y con diagnóstico de COVID-19, buscando no sólo el bienestar del paciente, sino también la seguridad del personal de salud.


Abstract: The COVID-19 pandemic has forced us to rethink the way we practice some aspects of medicine. Cardiopulmonary resuscitation is a practice that generates aerosol particles from the airway, which increases the risk of SARS-CoV-2 infection. In this review, the international recommendations on the subject are consulted, high-risk moments are defined and recommendations are established on compressions, ventilation, electrical therapy and even pharmacology in patients with cardiac arrest and with a diagnosis of COVID-19, seeking not only the well-being of the patient, but also the safety of health personnel.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA