Korean Journal of Anesthesiology ; : S13-S16, 2010.
Artigo em Inglês | WPRIM | ID: wpr-44816

RESUMO

We present a case of problematic tracheal intubation in an adult patient with an unrecognized tracheal bronchus. Immediately after tracheal intubation and position change to prone, bilateral breath sounds were almost absent, and there was a diminished tidal volume. In order to resolve the ventilatory difficulty, the wire-reinforced tube was replaced with a conventional tube, and proper positioning of the tube was completed under fiberoptic guidance. A tracheal bronchus (originating about 1.2 cm above the carina, and supplying the right upper lobe) was found on the postoperative chest CT. In the presence of tracheal bronchus, tracheal intubation may cause pulmonary complications. Anesthesiologists should keep in mind the anesthetic implications of tracheal bronchus, and must be familiar with the use of fiberoptic bronchoscopy for proper positioning of endotracheal tube.


Assuntos
Adulto , Humanos , Brônquios , Broncoscopia , Intubação , Intubação Intratraqueal , Tórax , Volume de Ventilação Pulmonar
2.
The Korean Journal of Pain ; : 142-146, 2010.
Artigo em Inglês | WPRIM | ID: wpr-162794

RESUMO

BACKGROUND: Stellate ganglion block (SGB) is known to increase blood flow to the innervations area of the stellate ganglion. Near infrared spectroscopy reflects an increased blood volume and allows continuous, non-invasive, and bedside monitoring of regional cerebral oxygen saturation (rSO2). We investigated the influence of SGB on bilateral cerebral oxygenation using a near infrared spectroscopy. METHODS: SGB was performed on 30 patients with 1% lidocaine 10 ml using a paratracheal technique at the C6 level and confirmed by the presence of Horner's syndrome. The blood pressure (BP), heart rate (HR) and rSO2 were measured before SGB and 5, 10, 15 and 20 minutes after SGB. Tympanic temperature of each ear was measured prior to SGB and 20 minutes after SGB. RESULTS: The increments of the rSO2 on the block side from the baseline were statistically significant at 5, 10, 15 and 20 minutes. The rSO2 on the non-block side compared with the baseline, however, decreased at 15 and 20 minutes. The difference between the block and the non-block sides was significant at 15 and 20 minutes. The BP at 10, 15 and 20 minutes was increased and the HR was increased at 10 and 15 minutes. CONCLUSIONS: We observed an increment of the rSO2 on the block side from the baseline; however, the rSO2 on the non-block side decreased.


Assuntos
Humanos , Pressão Sanguínea , Volume Sanguíneo , Orelha , Frequência Cardíaca , Síndrome de Horner , Lidocaína , Oxigênio , Análise Espectral , Gânglio Estrelado