Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Journal of Zhejiang University. Science. B ; (12): 342-348, 2018.
Artigo em Inglês | WPRIM | ID: wpr-772781

RESUMO

In aged patients, acute kidney injury (AKI) is a common clinical complication after percutaneous coronary intervention (PCI), highlighting the need for timely and certain diagnosis of this disease. A single centre, nested case-control study was conducted, which assessed the usefulness of urinary liver-type fatty acid-binding protein (uL-FABP), neutrophil gelatinase-associated lipocalin (uNGAL), and kidney injury molecule-1 (uKIM-1) for early detection of AKI. One hundred and thirty-two patients at or over 60 years old undergoing PCI were included. Serum creatinine (SCr) was measured before PCI, 24 and 48 h after PCI; uL-FABP, uNGAL, and uKIM-1 were measured before PCI, 6, 24, and 48 h after PCI. We identified 16 AKI patients and selected 32 control patients matched by admission time (<1 week), age (±5 years), and gender. In the receiver operating characteristic (ROC) curve analysis, the areas under the curve (AUCs) for the relative measurements of uL-FABP, uNGAL, and uKIM-1 were 0.809, 0.867, and 0.512 at 6 h after PCI, and 0.888, 0.840, and 0.676 at 24 h after PCI, respectively. AUC for the combination of uL-FABP and uNGAL was 0.899 at 6 h after PCI, and 0.917 at 24 h after PCI. Thus, measurement of uL-FABP and uNGAL levels at 6 and 24 h after PCI may be useful in detecting AKI in aged patients. Measurement of uKIM-1 levels provides inferior predictive power for early diagnosis of AKI.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Injúria Renal Aguda , Diagnóstico , Urina , Diagnóstico Precoce , Proteínas de Ligação a Ácido Graxo , Urina , Receptor Celular 1 do Vírus da Hepatite A , Lipocalina-2 , Urina , Intervenção Coronária Percutânea
2.
Chinese Journal of Cardiology ; (12): 662-666, 2012.
Artigo em Chinês | WPRIM | ID: wpr-326447

RESUMO

<p><b>OBJECTIVE</b>To evaluate the platelet inhibition efficacy in patients under regular maintenance dose of clopidogrel by VerifyNow-P2Y12 assay and explore the clinical characteristics of clopidogrel non-responders and related predicting factors.</p><p><b>METHODS</b>A total of 99 patients underwent percutaneous coronary intervention procedure and receiving clopidogrel in regular maintenance dose for at least 1 week were enrolled. Platelet reactivity, including baseline, P2Y12 reaction unit (PRU), and platelet inhibition rate were measured with VeifyNow-P2Y12 assay. The dosage of anti-platelet drugs, combination with any other drugs, clinical characters in baseline of all enrolled patients were analyzed. PRU ≤ 240 was used as cut-off to identify clopidogrel responder and clopidogrel non-responder. In the non-responder group, patients were further separated into 3 sub-groups (types) according to the baseline and platelet inhibition rate: type I with high baseline, high inhibition rate, representing false non-responder; type II with low inhibition rate, representing true non-responder and type III mixed type.</p><p><b>RESULTS</b>In this study, 48 of 99 patients were found to be clopidogrel non-responder (48.5%). The ratio of type I, type II and type III in the non-responder group was 9.1% (n = 9), 27.3% (n = 27), and 12.1% (n = 12), respectively. Baseline platelet value in female patients was significantly higher than in males (P < 0.01), number of females with high PRU also is higher than males (P < 0.01), female gender was a predict factor for type I non-responder (OR = 6.5, 95%CI 2.295 - 18.407, P < 0.01). BMI > 24 kg/m(2) was a risk factor for clopidogrel non-responder (P < 0.05), and may be regarded as a predict factor for type II non-responder (OR = 3.207, 95%CI 1.375 - 7.485, P < 0.01). Age, hypertension, diabetics, smoking, hyperlipidemia, CRP and pantoprazole use do not show significant correlation with baseline and platelet inhibition rate.</p><p><b>CONCLUSIONS</b>Clopidogrel responses could be reliably detected by VerifyNow-P2Y12 assay. Female gender and high body weight are independent risk factors for clopidogrel non-responses.</p>


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angioplastia Coronária com Balão , Agregação Plaquetária , Inibidores da Agregação Plaquetária , Farmacologia , Testes de Função Plaquetária , Receptores Purinérgicos P2Y12 , Ticlopidina , Farmacologia
3.
Chinese Journal of Cardiology ; (12): 487-491, 2012.
Artigo em Chinês | WPRIM | ID: wpr-275019

RESUMO

<p><b>OBJECTIVE</b>To evaluate the diagnostic accuracy of 320-slice CT coronary angiography (CTA) in the evaluation of in-stent restenosis (ISR, ≥50% luminal narrowing) in comparison with quantitative coronary angiography (CAG).</p><p><b>METHODS</b>A total of 69 patients with previous stent implantation who underwent both CTA and CAG were prospectively included. We assessed diagnostic valve for ISR with CTA in comparison with CAG.</p><p><b>RESULTS</b>A total of 110 stents were implanted in these patients.CAG identified 14 ISR. CTA correctly identified 13 ISR and misdiagnosed 5 ISR in stents without ISR. Besides, 6 stents could not be evaluated by CTA due to unsatisfied image quality. Accordingly, sensitivity, specificity, positive and negative predictive value of CTA for diagnosing ISR were 93%, 89%, 54% and 99%, respectively. The image quality of CTA was significantly better in larger stents (percentages of good and moderate stent image of ≥3.0 mm and <3.0 mm: 56% vs. 27%, 25% vs. 49%) and which was linked with better diagnostic coincidence rate (95% vs. 78%) for larger stents. The image quality of CTA was significantly better in stents with thinner stent strut thickness (percentages of poor CTA stent image quality of stent strut thickness<140 µm and ≥140 µm: 12% vs. 45%, P<0.01) and which was associated with better diagnostic coincidence rate for stents with thinner stent strut thickness (94% vs. 76%, P<0.05). The image quality of CTA was also significantly better in single stent (percentages of poor CTA stent image quality of single stent vs. overlap and dedicated stent: 17% vs. 36%, P<0.05). However, heart rate (≥65 beats/min vs. <65 beats/min) during CTA acquisition was not associated with image quality and the diagnostic coincidence rate (all P>0.05).</p><p><b>CONCLUSIONS</b>Our results indicate that 320-slice CTA allows accurate noninvasive assessment of significant in-stent restenosis in selected patients. Stents with a large diameter and thin struts are associated with better image quality and higher diagnostic accuracy.</p>


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angiografia Coronária , Reestenose Coronária , Diagnóstico por Imagem , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Stents , Tomografia Computadorizada por Raios X , Métodos
4.
Chinese Journal of Cardiology ; (12): 648-651, 2007.
Artigo em Chinês | WPRIM | ID: wpr-307227

RESUMO

<p><b>OBJECTIVE</b>To explore the diagnostic feasibility of noninvasive assessment of coronary atherosclerotic plaques with MSCT in comparison with IVUS.</p><p><b>METHODS</b>Contrast-enhanced MSCT angiography (Sensation 64, Siemens Medical Solutions) was performed before percutaneous coronary intervention (PCI), and three-vessel IVUS (Boston Scientific, Natick, MA) was performed during procedure in 12 patients with stable angina pectoris. Complete investigation was digitally stored, and assessed offline with EchoPlaque (Indec Systems, Mountain View, CA). The comparison of MSCT with IVUS was performed based on segment at plaque site (American Heart Association 15-segment model).</p><p><b>RESULTS</b>A total of 88 segments in 31 vessels (left anterior descending: 12, left circumflex: 10, and right coronary artery: 9) were investigated by both IVUS and MSCT. Among 68 assessable segments (54 proximal-middle segments and 14 distal segments) by MSCT (20 segments were excluded for poor image quality: 16 for severe calcification, 2 for motion artifact, 2 for poor opacification), MSCT correctly detected 47 of the 51 segments with plaques (sensitivity: 92%), and correctly evaluated 16 of 17 segments without plaques (specificity: 94%). Concerning plaque quantification, MSCT correlated well with IVUS in grading whether the vessel obstruction was less or more than 50% (simple kappa: 0.63, 95% CI: from 0.47 to 0.78). Plaque area by MSCT also correlated with that by IVUS (r = 0.53, P < 0.01), but overestimated plaque area [(9.09 +/- 3.89) mm(2) vs. (6.80 +/- 2.81) mm(2), P < 0.01]. In addition, 30 of 43 hypoechoic compositions were detected as low-density compositions by MSCT with average CT number as 67.39 HU.</p><p><b>CONCLUSIONS</b>In segments without severe calcification, contrast-enhanced 64-slice CT angiography could detect plaques in coronary artery with high accuracy. Plaque area quantification by MSCT correlated with that of IVUS though with limited accuracy.</p>


Assuntos
Humanos , Angiografia Coronária , Doença da Artéria Coronariana , Diagnóstico por Imagem , Tomografia Computadorizada por Raios X , Métodos , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA