Chinese Journal of Orthopaedics ; (12): 1631-1639, 2021.
Artigo em Chinês | WPRIM | ID: wpr-910757

RESUMO

Objective:In this study, a gait acquisition and analysis system is developed to provide a cheap, easy-to-use solution for quantitative recording and analysis of patients' gaits.Methods:From April 2017 to October 2018, we collected the gait data of 19 patients with knee osteoarthritis and 19 healthy volunteers in the orthopaedic outpatient department. Among 19 patients, there were 9 males and 10 females, aged 50.1±9.4 years old. Among 19 healthy volunteers, there were 8 males and 11 females, aged 50.7±10.3 years old. Then, from the collected gait data, the static gait features such as gait speed, step length, stride, and dynamic gait features were automatically calculated, and the statistical difference analysis was finished to determine the correlation between these quantitative gait features and knee osteoarthritis.Results:Firstly, the gait data collected by the depth camera was compared with the data from the multi infrared camera-based motion analysis system (gold standard). The average angle error of the collected knee joint angle was 0.98 degrees, which proved the correctness of the gait data recorded by the depth camera. The statistical difference analysis of gait characteristics between the patient group and the healthy group showed that the gait characteristics with P<0.05 included: gait speed ( r=-0.922, P<0.001), step length ( r=-0.897, P=0.004), stride ( r=-0.914 , P<0.001), dynamic characteristics of angle of knee joint ( r=0.775, P=0.001). Conclusion:The gait acquisition and analysis system based on the depth camera can accurately record and store the gait data of the patients with knee osteoarthritis. Moreover, the extracted quantitative gait features have statistical differences between the patients and the healthy group, which is helpful for the gait analysis of bone joint.

2.
Chinese Journal of Digestive Surgery ; (12): 986-991, 2019.
Artigo em Chinês | WPRIM | ID: wpr-796801

RESUMO

Objective@#To investigate the application value of augmented reality (AR) technology in pancreatoduodenectomy (PD).@*Methods@#The retrospective and descriptive study was conducted. The clinicopathological data of 3 male patients who underwent PD in Tsinghua University Affiliated Beijing Tsinghua Changgung Hospital from June 2018 to February 2019 were collected. The 3 patients were aged from 52 to 63 years, with a median age of 57 years. Digital imaging and communication standard format data of enhanced computed tomography (CT) scan were collected, the three-dimensional (3D) images of abdominal arteries, portal vein, descending duodenum, pancreatic body and tail, pancreatic head, common bile duct, and pancreatic duct were reconstructed. The results were imported into the AR software. Optical tracking based on two-dimensional codes and manual interactive rigid registration were adopted for intraoperative navigation. Observation indicators: (1) surgical and postoperative conditions; (2) postoperative pathological examination; (3) follow-up. Follow-up using outpatient examination or telephone interview was conducted to detect survival of patients and tumor metastasis and recurrence up to June 2019. The measurement data with skewed distribution were expressed as M (range). Count data were expressed as absolute numbers.@*Results@#(1) Surgical and postoperative conditions: all the 3 patients underwent PD with AR technology as intraoperative navigation successfully. The operation time, volume of intraoperative blood loss, and duration of postoperative hospital stay were 6 hours (range, 5-8 hours), 700 mL (range, 300-900 mL), 11 days (range, 9-12 days). There was no perioperative death or complication occured. After surgery, the patients who underwent PD combined with superior mesenteric vein (SMV) resection and reconstruction had patent SMV on the enhanced computed tomography examination. (2) Postoperative pathological examination: results of pathological examination showed 1 case of intraductal papillary mucinous neoplasm (IPMN) of the pancreas with invasive adenocarcinoma (neoplasm invading SMV), 1 case of insulinoma, and 1 case of periampullary neuroendocrine carcinoma, respectively. (3) Follow-up: 3 patients were followed up for 4-12 months, with a median follow-up time of 6 months. During the follow-up, the patient with IPMN of the pancreas and invasive adenocarcinoma had liver metastasis at 3 months after surgery, and received chemotherapy at other hospital. After 4 cycles of chemotherapy, the metastatic nodule shrank, and the patient was still in follow-up up to deadline of follow-up. Other 2 patients had no recurrence or metastasis.@*Conclusion@#AR technique assisted PD is safe and feasible, which is helpful to indentify vascular branches and tracks.

3.
Chinese Journal of Digestive Surgery ; (12): 986-991, 2019.
Artigo em Chinês | WPRIM | ID: wpr-790108

RESUMO

Objective To investigate the application value of augmented reality (AR) technology in pancreatoduodenectomy (PD).Methods The retrospective and descriptive study was conducted.The clinicopathological data of 3 male patients who underwent PD in Tsinghua University Affiliated Beijing Tsinghua Changgung Hospital from June 2018 to February 2019 were collected.The 3 patients were aged from 52 to 63 years,with a median age of 57 years.Digital imaging and communication standard format data of enhanced computed tomography (CT) scan were collected,the three-dimensional (3D) images of abdominal arteries,portal vein,descending duodenum,pancreatic body and tail,pancreatic head,common bile duct,and pancreatic duct were reconstructed.The results were imported into the AR software.Optical tracking based on two-dimensional codes and manual interactive rigid registration were adopted for intraoperative navigation.Observation indicators:(1) surgical and postoperative conditions;(2) postoperative pathological examination;(3) follow-up.Follow-up using outpatient examination or telephone interview was conducted to detect survival of patients and tumor metastasis and recurrence up to June 2019.The measurement data with skewed distribution were expressed as M (range).Count data were expressed as absolute numbers.Results (1) Surgical and postoperative conditions:all the 3 patients underwent PD with AR technology as intraoperative navigation successfully.The operation time,volume of intraoperative blood loss,and duration of postoperative hospital stay were 6 hours (range,5-8 hours),700 mL (range,300-900 mL),11 days (range,9-12 days).There was no perioperative death or complication occured.After surgery,the patients who underwent PD combined with superior mesenteric vein (SMV) resection and reconstruction had patent SMV on the enhanced computed tomography examination.(2) Postoperative pathological examination:results of pathological examination showed 1 case of intraductal papillary mueinous neoplasm (IPMN) of the pancreas with invasive adenocarcinoma (neoplasm invading SMV),1 case of insulinoma,and 1 case of periampullary neuroendocrine carcinoma,respectively.(3) Follow-up:3 patients were followed up for 4-12 months,with a median follow-up time of 6 months.During the follow-up,the patient with IPMN of the pancreas and invasive adenocarcinoma had liver metastasis at 3 months after surgery,and received chemotherapy at other hospital.After 4 cycles of chemotherapy,the metastatic nodule shrank,and the patient was still in follow-up up to deadline of follow-up.Other 2 patients had no recurrence or metastasis.Conclusion AR technique assisted PD is safe and feasible,which is helpful to indentify vascular branches and tracks.

4.
Chinese Journal of Digestive Surgery ; (12): 433-436, 2017.
Artigo em Chinês | WPRIM | ID: wpr-512835

RESUMO

Objective To explore the feasibility of electromagnetic navigation for hepatic ducts exploration by choledochoscope based on a three-dimensional (3D) printing model.Methods The retrospective descriptive study was conducted.The clinical data of 1 patient with obstructive jaundice combined with secondary biliary tract dilation who was admitted to the Beijing Tsinghua Changgung Hospital in April 2016 were collected.Digital imaging and standardized format data of enhanced computed tomography (CT) scan were collected,3D reconstruction of liver and bile duct were done under a 3D printing model,and then a hollow model of bile duct was achieved.Choledochoscope with internal electromagnetic probe was inserted into the printed hepatic ducts.Four points of anatomical markers in left and right hepatic ducts and common hepatic duct were chosen as fiducial markers for calibration and registration.Results After registration,the scope can be tracked in main hepatic segmental bile ducts.The locations of choledochoscope matched precisely the navigation results.Conclusion Electromagnetic navigation may bring accurate tracking effectiveness for choledochoscopic examination.

5.
International Journal of Oral Science ; (4): 98-102, 2013.
Artigo em Inglês | WPRIM | ID: wpr-358190

RESUMO

To evaluate the feasibility and accuracy of a three-dimensional augmented reality system incorporating integral videography for imaging oral and maxillofacial regions, based on preoperative computed tomography data. Three-dimensional surface models of the jawbones, based on the computed tomography data, were used to create the integral videography images of a subject's maxillofacial area. The three-dimensional augmented reality system (integral videography display, computed tomography, a position tracker and a computer) was used to generate a three-dimensional overlay that was projected on the surgical site via a half-silvered mirror. Thereafter, a feasibility study was performed on a volunteer. The accuracy of this system was verified on a solid model while simulating bone resection. Positional registration was attained by identifying and tracking the patient/surgical instrument's position. Thus, integral videography images of jawbones, teeth and the surgical tool were superimposed in the correct position. Stereoscopic images viewed from various angles were accurately displayed. Change in the viewing angle did not negatively affect the surgeon's ability to simultaneously observe the three-dimensional images and the patient, without special glasses. The difference in three-dimensional position of each measuring point on the solid model and augmented reality navigation was almost negligible (<1 mm); this indicates that the system was highly accurate. This augmented reality system was highly accurate and effective for surgical navigation and for overlaying a three-dimensional computed tomography image on a patient's surgical area, enabling the surgeon to understand the positional relationship between the preoperative image and the actual surgical site, with the naked eye.


Assuntos
Humanos , Calibragem , Apresentação de Dados , Estudos de Viabilidade , Processamento de Imagem Assistida por Computador , Métodos , Imageamento Tridimensional , Métodos , Mandíbula , Maxila , Modelos Anatômicos , Dispositivos Ópticos , Procedimentos Cirúrgicos Bucais , Métodos , Projetos Piloto , Técnicas Estereotáxicas , Cirurgia Assistida por Computador , Métodos , Tomografia Computadorizada por Raios X , Métodos , Dente , Interface Usuário-Computador , Gravação em Vídeo , Métodos