Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Peking University(Health Sciences) ; (6): 964-970, 2020.
Artigo em Chinês | WPRIM | ID: wpr-942105

RESUMO

OBJECTIVE@#To evaluate the digital workflow coupling conic retention for the immediate restoration of adjacent posterior implants.@*METHODS@#The patients with adjacent teeth missing in the posterior jaw seeking for implant restoration in the Department of Implantology, Peking University School and Hospital of Stomatology from March, 2017 to February, 2018 were recruited. After implant placement and commercial conic retention coping delivery, the patient had an intraoral scan for digital impression, and the computer-assisted design/computer-assisted manufacturing (CAD/CAM) technology was used for the fabrication of the immediate splinted prosthesis, which was made of polymethyl methacrylate (PMMA) and loaded immediately after delivery. Six months later, all the temporary prostheses were replaced by the permanent ones made of monolithic zirconia with CAD/CAM technology as well. The parallel periapical films were taken for the temporary and permanent prostheses post-delivery. The clinical effect of this workflow was evaluated by indices including the survival rates of implants and prostheses, the change of marginal bone level, and the implant-related and prosthesis-related complications; before the final restoration, the Visual Analogue Score (VAS) was used to evaluate the satisfaction of the patients.@*RESULTS@#Ten patients (4 males and 6 females, 55.5 years old for average) were recruited. Totally 34 implants were placed; 14 prostheses were fabricated, temporary and permanent, respectively. After an observation period from 4 to 14 months, the survival rate for implants and prostheses were both 100%; the marginal bone level of the implants were (1.06±0.97) mm and (0.96±0.82) mm, immediate post-operation and 6 months later, respectively. The difference was not statistically significant (P>0.05). Neither implant- nor prostheses- related complications were observed. And the VAS of the patients' satisfaction was 87.2.@*CONCLUSION@#For the adjacent posterior implants, the immediate prostheses manufactured by digital workflow, coupling conic retention, were clinically feasible and patient-satisfactory.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho Assistido por Computador , Satisfação do Paciente , Próteses e Implantes , Implantação de Prótese , Fluxo de Trabalho
2.
Journal of Peking University(Health Sciences) ; (6): 924-930, 2020.
Artigo em Chinês | WPRIM | ID: wpr-942098

RESUMO

OBJECTIVE@#To explore the applicability of integration between three-dimensional (3D) facial and dental data to evaluate the nasolabial morphology variation before and after the cross-arch fixed restoration of the maxillary implant-supported prostheses.@*METHODS@#Twelve patients (4 women and 8 men), mean age (54.82±5.50) years (from 45 to 62 years) referred to the Department of Oral Implan-tology, Peking University School and Hospital of Stomatology, were selected and diagnosed with edentulous maxilla. For all the patients, 4 to 6 implants were inserted into the maxilla. Six months later, the final cross-arch fixed prostheses were delivered. The 3D facial images were collected before and after the final restoration. The 3D data of prostheses were also captured. All the 3D data were registered and measured in the same coordinate system. Then the displacement of all the landmarks [cheilion left (CHL), cheilion right (CHR), crista philtri left (CPHL), crista philtri right (CPHR), labrale supe-rius (LS), subnasale (SN), stomion (STO), upper incisor (UI), upper flange border of the prostheses (F-point, F)], and the variation of the distances between these landmarks (SN-LS, CPHR-CPHL, CHR-CHL, LS-STO) were analyzed and compared.@*RESULTS@#The consistency test among three measurements of the length of F-SN indicated that the integration method of the dental prostheses and soft tissue had the good repetitiveness, ICC=0.983 (95%CI: 0.957-0.995). After wearing the final cross-arch maxillary implant-supported prostheses, all the landmarks on the soft tissue moved forward. The nasal base area changed minimally, and the shift of SN in the sagittal direction was only (0.61±0.44) mm. But the sagittal shift of LS was (3.12±1.38) mm. In the vertical direction, SN, LS, CPHL, and CPHR moved upward. But STO, CHL, and CHR moved downward a little. Except for the slight decrease of the length of philtrum (SN-LS), the length of CHL-CHR, CPHL-CPHR, and the height of upper lip were increased together (P < 0.01). In the direction of Z axis, the strong correlations were found not only between the movements of SN and F (r=0.904 3) but also between the movements of LS and UI (r=0.958 4).@*CONCLUSION@#The integration method of 3D facial and dental data showed good repetitiveness. And the strong correlations between the landmarks of prostheses and nasolabial soft tissue in the sagittal direction were found by this new method.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Incisivo , Lábio , Maxila/cirurgia , Boca Edêntula , Próteses e Implantes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA