Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 457-460, 2023.
Artigo em Chinês | WPRIM | ID: wpr-986050

RESUMO

Objective: To establish a high performance liquid chromatography method for the determination of misoprostol in workplace air. Methods: From February to August 2021, the misoprostol in the workplace air was collected by glass fiber filter membrane, and theeluent was separated by C18 liquid chromatography column, determined by UV detector, and quantified by external standard method. Results: The quantitative lower limit of misoprostol determination method was 0.05 μg/ml, and the lowest quantitative concentration was 1.4 μg/m(3) (calculated by collecting 75 L air sample). The concentration of misoprostol has a good linear relationship between 0.05 to 10.00 μg/ml. The relative coefficient was 0.9998. The regression equation of the standard working curve was y=495759x-45257. The range of average recovery rates were from 95.5% to 102.8%. The intra-assay precision of the method was 1.2%-4.6%, and the inter-assay precision was 2.0%-5.9%. The samples could be stored stably for 7 days at 4 ℃. Conclusion: The high performance liquid chromatography method for the determination of misoprostol has high sensitivity, good specificity and simple procedure of sample pretreatment. It is suitable for the detection of misoprostol in the workplace air.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Misoprostol/análise , Poluentes Ocupacionais do Ar/análise , Local de Trabalho , Cromatografia Líquida
2.
Chinese Journal of Contemporary Pediatrics ; (12): 955-959, 2019.
Artigo em Chinês | WPRIM | ID: wpr-775075

RESUMO

OBJECTIVE@#To study the clinical effect and safety of double filtration plasmapheresis (DFPP) combined with double pulse therapy with methylprednisolone (MP) and cyclophosphamide (CTX) in the treatment of children with severe Henoch-Schönlein purpura nephritis (HSPN).@*METHODS@#A total of 60 children with severe HSPN who were admitted to the hospital from January 2014 to March 2018 were enrolled and were randomly divided into an observation group and a control group (n=30 each). In addition to routine treatment, the children in the control group were given MP+CTX pulse therapy. Those in the observation group were given DFPP treatment in addition to the treatment in the control group, with three courses of treatment in total. After three courses of treatment, the two groups were compared in terms of 24-hour urinary protein, urinary microproteins, renal function parameters, adverse reactions, and clinical outcome.@*RESULTS@#After three courses of treatment, the observation group had significantly greater reductions in 24-hour urinary protein, urinary albumin, urinary immunoglobulin G, urinary β2-microglobulin, serum creatinine, and blood urea nitrogen than the control group (P0.05).@*CONCLUSIONS@#Compared with MP+CTX pulse therapy alone in the treatment of severe HSPN in children, DFPP combined with MP+CTX pulse therapy can further alleviate renal injury and improve clinical outcome and does not increase the incidence rate of adverse reactions.


Assuntos
Criança , Humanos , Glucocorticoides , Imunossupressores , Nefrite , Plasmaferese , Vasculite por IgA
3.
Biomedical and Environmental Sciences ; (12): 379-384, 2016.
Artigo em Inglês | WPRIM | ID: wpr-258809

RESUMO

Case reports of indium-related lung disease in workers have raised public concern to the human toxicity of indium (In) and its compounds. However, studies evaluating the exposure or health of workers in In smelting plants are rare. Therefore, in this study, we focused on four In smelting plants, with the main objective of characterizing In in smelter plants in China and discussing the potential exposure biomarkers of In exposure. We recruited 494 subjectsat four In smelting plants in China. Personal air samples, first morning urine and spot blood samples were collected. In concentrations in samples were analyzed using inductively coupled plasma mass spectrometry. In concentrations in air samples did not exceed the permissible concentration-time weighed average, but the smelter workers had a higher internal exposure to In. Positive correlations were observed between the air In and urine In concentrations, and between the air In and blood In concentrations. This study provides basic data for the following In exposure and health risk assessment.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Poluentes Ocupacionais do Ar , Sangue , Urina , Biomarcadores , Sangue , Urina , China , Monitoramento Ambiental , Índio , Sangue , Urina , Espectrometria de Massas , Metalurgia , Exposição Ocupacional
4.
Chinese Journal of Preventive Medicine ; (12): 679-682, 2012.
Artigo em Chinês | WPRIM | ID: wpr-326249

RESUMO

<p><b>OBJECTIVE</b>To evaluate the chromium (Cr) levels in blood and urine among general population in China between 2009 and 2010, and thereby to analyze its prevalent features.</p><p><b>METHODS</b>From year 2009 to 2010, a total of 11 983 subjects of general population aged between 6 and 60 year-old were recruited from 24 districts in 8 provinces in eastern, central and western China mainland, by cluster random sampling method. The information about their living environment and health status were collected by questionnaire, and 11 983 blood samples and 11 853 urine samples were also collected. Inductively coupled plasma mass spectrometry (ICP-MS) was applied to test the Cr level both in blood and urine; and the Cr distribution in blood and urine among groups of population in different ages, genders and districts, were then analyzed.</p><p><b>RESULTS</b>Among general population in China, the geometric mean (GM) of Cr concentration in blood was 1.19 µg/L, with median at 1.74 µg /L and 95% percentile at 5.59 µg/L. The Cr concentration in blood among males and females were separately 1.18 µg/L and 1.20 µg/L(P > 0.05); while its GM in the groups of population aged 6 - 12, 12 - 16, 16 - 20, 20 - 30, 30 - 45 and 45 - 60 years old were 1.00, 1.22, 1.01, 1.40, 1.27 and 1.30 µg/L (P < 0.01), respectively; and the figures in populations from eastern, central and western China were 1.00, 1.70 and 1.98 µg/L (P < 0.01), respectively. Among general population, the GM of Cr concentration in urine was 0.53 µg/L, with median was lower than 0.42 µg/L and 95% percentile at 3.53 µg/L. The Cr concentration in urine among males and females were separately 0.52 µg/L and 0.53 µg/L (P > 0.05);while its GM in the groups of population aged 6 - 12, 12 - 16, 16 - 20, 20 - 30, 30 - 45 and 45 - 60 years old were 0.56, 0.60, 0.52, 0.50, 0.52 and 0.46 µg/L (P < 0.01), respectively;and the figures in populations from eastern, central and western China were 0.58, < 0.42 and 0.60 µg/L (P < 0.01), respectively.</p><p><b>CONCLUSION</b>The study reported the Cr levels in blood and urine among general population in China, and thereby provided basic data evidence for the following Cr biological monitoring studies in near future.</p>


Assuntos
Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , China , Cromo , Sangue , Urina , Vigilância da População
5.
Chinese Journal of Preventive Medicine ; (12): 745-749, 2012.
Artigo em Chinês | WPRIM | ID: wpr-326235

RESUMO

<p><b>OBJECTIVE</b>To establish an inductively coupled plasma mass spectrometry(ICP-MS) method for determination of 30 trace elements including As, Ba, Be, Bi, Ni, Cd, Co, Cr, Cs, Cu, Ga, Mn, Pb, Sr, Tl, V, Ge, Mo, Nb, Ti, W, Te, Se, Zr, In, Sb, Hg, Ce, La, and Sm in human blood.</p><p><b>METHOD</b>The blood samples were analyzed by ICP-MS after diluted 1/10 with 0.01% Triton-X-100 and 0.5% nitric acid solution. Y, Rh and Lu were selected as internal standard in order to correct the matrix interference of Cr, As, Se, and Hg by a hex pole-based collision-reaction cell. Other elements were determined with standard method. The limits of detection, precision and accuracy of the method were evaluated. The accuracy was validated by the determination of the whole blood reference material.</p><p><b>RESULTS</b>All the 30 trace elements have good linearity in their determination range, with the correlation coefficient > 0.9999. The limits of detection of the 30 trace elements were in the range of 1.19 - 2.15 µg/L and the intra-precision and inter-precision (relative standard deviation, RSD) were less than 14.3% (except Hg RSD < 21.2%, and Ni RSD < 15.4%). The spiked recovery for all elements fell within 59.3% - 119.2%. Among the 13 whole blood reference materials, V, Cr, Mn, Co, Ni, Cu, As, Se, Cd, Te, and Pb (1.45, 1.19, 18.40, 0.18, 1.57, 591.00, 2.97, 61.00, 0.35, 1.86, and 9.70 µg/L respectively) fell within the acceptable range and the detection results of Hg (0.59 µg/L) and Mo (1.59 µg/L) were slightly beyond the range.</p><p><b>CONCLUSION</b>This method was simple, fast and effective. It can be used to monitor the multi-elementary concentration in human blood.</p>


Assuntos
Humanos , Limite de Detecção , Espectrometria de Massas , Métodos , Metaloides , Sangue , Metais , Sangue , Oligoelementos , Sangue
6.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 139-141, 2011.
Artigo em Chinês | WPRIM | ID: wpr-272639

RESUMO

<p><b>OBJECTIVE</b>To develop the certified reference material of mercury in lyophilized human urine.</p><p><b>METHODS</b>Human urine samples from normal level mercury districts were filtered, homogenized, dispensed, lyophilized and radio-sterilized. Homogeneity test, stability inspection and certification were conducted using a atom fluorescence spectrophotometric method. The physical and chemical stability of the certified reference material were assessed for 18 months. The certified values are based on analysis made by three independent laboratories.</p><p><b>RESULTS</b>The certified values are as follows: low level was (35.6 ± 2.1) µg/L, high level was (50.5 ± 3.0) µg/L.</p><p><b>CONCLUSION</b>The certified reference material of mercury in lyophilized human urine in this research reached the national certified reference material requirements and could be used for the quality control.</p>


Assuntos
Humanos , Liofilização , Padrões de Referência , Mercúrio , Urina , Padrões de Referência , Espectrometria de Fluorescência , Urinálise , Padrões de Referência
7.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 450-451, 2011.
Artigo em Chinês | WPRIM | ID: wpr-282574

RESUMO

<p><b>OBJECTIVE</b>An atomic fluorescence (AFS) method was developed to determine germanium hydride in the air of workplace.</p><p><b>METHOD</b>Germanium hydride in the air of workplace was collected by charcoal tube, and desorbed by nitric acid followed filtration with 0.22 microm cellulose filter, the AFS was used to determine Germanium in the desorbed solution.</p><p><b>RESULTS</b>The linear was good at the range of 0.85-300 microg/L with the correlation coefficient of 0.9993; the LOD and LOQ were 0.51 microg/L and 0.000 17 mg/m3, respectively. The recovery was ranged from 90% to 106%, the RSD of intra- and inter- precision were 3.3%-5.9% and 3.7%-6.3%.</p><p><b>CONCLUSION</b>The linear range, sensitivity and precision of the method were all satisfied for the determination of germanium hydride in the air of workplace.</p>


Assuntos
Poluentes Ocupacionais do Ar , Monitoramento Ambiental , Métodos , Germânio , Espectrofotometria Atômica , Local de Trabalho
8.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 452-454, 2011.
Artigo em Chinês | WPRIM | ID: wpr-282573

RESUMO

<p><b>OBJECTIVE</b>A sampling method was established to collect diborane in the air of workplace and an ICP-AES method was developed to determine the Boron in desorbed solution.</p><p><b>METHOD</b>Diborane in the air of workplace was collected by solid sorbent tube filled with oxidant impregnated activated carbon. The adsorbed diborane was desorbed into 3% H2O2 aqueous, and then the desorbed Boron was determined by ICP-AES.</p><p><b>RESULTS</b>The sampling efficiency of this method was 99.6% with the desorption efficiency of diborane with 5.660 microg and 56.6 microg spiked were 90.9% and 99.5%, respectively. Both the intra-and inter-precision RSD were less than 8%. The standard curve of this method ranged from 0.1 to 10.0 microg/ml (Boron), and the LOD and LOQ were 0.011 mg/m3 and 0.035 mg/m3 (15L samples) respectively.</p><p><b>CONCLUSION</b>The method established was suitable for diborane sampling and determination in the air of workplace.</p>


Assuntos
Poluentes Ocupacionais do Ar , Boroidretos , Monitoramento Ambiental , Métodos , Espectrofotometria Atômica , Métodos , Local de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA