2.
Korean Journal of Anesthesiology ; : 440-443, 2011.
Artigo em Inglês | WPRIM | ID: wpr-226272

RESUMO

Excess absorption of fluid distention media remains an unpredictable complication of operative hysteroscopy and may lead to lethal conditions. We report an extreme hyponatremia, caused by using an electrolyte-free 5 : 1 sorbitol/mannitol solution as distention/irrigation fluid for hysteroscopic myomectomy. A 34-year-old female developed severe pulmonary edema and extreme hyponatremia (83 mmol/L) during transcervical endoscopic myomectomy. A brain computed tomography showed mild brain swelling without pontine myelinolysis. The patient almost fully recovered in two days. Meticulous attention should be paid to intraoperative massive absorption of fluid distention media, even during a simple hysteroscopic procedure.


Assuntos
Adulto , Feminino , Humanos , Absorção , Acidose , Encéfalo , Edema Encefálico , Hiponatremia , Histeroscopia , Edema Pulmonar
3.
The Korean Journal of Pain ; : 24-27, 2010.
Artigo em Inglês | WPRIM | ID: wpr-86977

RESUMO

BACKGROUND: Fluoroscopy has been an integral part of modern interventional pain management. Yet fluoroscopy can be associated with risks for the patients and clinicians unless it is managed with appropriate understanding, skill and vigilance. Therefore, this study was designed to determine the amount of radiation received by a primary operator and an assistant during interventional pain procedures that involve the use of fluoroscopy METHODS: In order to examine the amount of radiation, the physicians were monitored by having them wear three thermoluminescent badges during each single procedure, with one under a lead apron, one under the apron collar and one on the leg during each single procedure. The data obtained from each thermoluminescent badge was reviewed from September 2008 to November 2008 and the annual radiation exposure was subsequently calculated. RESULTS: A total of 505 interventional procedures were performed with C-arm fluoroscopy during three months. The results of this study revealed that the annual radiation exposure was relatively low for both the operator and assistant. CONCLUSION: With proper precautions, the use of fluoroscopy during interventional pain procedures is a safe practice.


Assuntos
Humanos , Fluoroscopia , Perna (Membro) , Manejo da Dor
SELEÇÃO DE REFERÊNCIAS