Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Korean Journal of Radiology ; : 39-46, 2016.
Artigo em Inglês | WPRIM | ID: wpr-222275

RESUMO

OBJECTIVE: To investigate the significance of intra-appendiceal air at CT for the evaluation of appendicitis. MATERIALS AND METHODS: We retrospectively analyzed 458 patients (216 men, 242 women; age range, 18-91 years) who underwent CT for suspected appendicitis. Two independent readers reviewed the CT. Prevalence, amount, and appearance of intra-appendiceal air were assessed and compared between the patients with and without appendicitis. Performance of CT diagnosis was evaluated in two reading strategies: once ignoring appendiceal air (strategy 1), and the other time considering presence of appendiceal air as indicative of no appendicitis in otherwise indeterminate cases (strategy 2), using receiver operating characteristic (ROC) analysis. RESULTS: Of the 458 patients, 102 had confirmed appendicitis. The prevalence of intra-appendiceal air was significantly different between patients with (13.2%) and without (79.8%) appendicitis (p < 0.001). The amount of appendiceal air was significantly lesser in patients having appendicitis as compared with the normal group, for both reader 1 (p = 0.011) and reader 2 (p = 0.002). Stool-like appearance and air-fluid levels were more common in the appendicitis group than in the normal appendix for both readers (p < 0.05). Areas under the ROC curves were not significantly different between strategies 1 and 2 in reader 1 (0.971 vs. 0.985, respectively; p = 0.056), but showed a small difference in reader 2 (0.969 vs. 0.986, respectively; p = 0.042). CONCLUSION: Although significant differences were seen in the prevalence, amount, and appearance of intra-appendiceal air between patients with and without appendicitis, it has a limited incremental value for the diagnosis of acute appendicitis.


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Doença Aguda , Apendicite/patologia , Apêndice/patologia , Prevalência , Curva ROC , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
2.
Korean Journal of Radiology ; : 607-615, 2013.
Artigo em Inglês | WPRIM | ID: wpr-174746

RESUMO

OBJECTIVE: Though a number of CT findings of bowel and mesenteric injuries in blunt abdominal trauma are described in literature, no studies on the specific CT signs of a transected bowel have been published. In the present study we describe the incidence and new CT signs of bowel transection in blunt abdominal trauma. MATERIALS AND METHODS: We investigated the incidence of bowel transection in 513 patients admitted for blunt abdominal trauma who underwent multidetector CT (MDCT). The MDCT findings of 8 patients with a surgically proven complete bowel transection were assessed retrospectively. We report novel CT signs that are unique for transection, such as complete cutoff sign (transection of bowel loop), Janus sign (abnormal dual bowel wall enhancement, both increased and decreased), and fecal spillage. RESULTS: The incidence of bowel transection in blunt abdominal trauma was 1.56%. In eight cases of bowel transection, percentage of CT signs unique for bowel transection were as follows: complete cutoff in 8 (100%), Janus sign in 6 (100%, excluding duodenal injury), and fecal spillage in 2 (25%). The combination of complete cutoff and Janus sign were highly specific findings in patients with bowel transection. CONCLUSION: Complete cut off and Janus sign are the unique CT findings to help detect bowel transection in blunt abdominal trauma and recognition of these findings enables an accurate and prompt diagnosis for emergency laparotomy leading to reduced mortality and morbidity.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos Abdominais/diagnóstico por imagem , Intestinos/lesões , Tomografia Computadorizada Multidetectores/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ruptura , Ferimentos não Penetrantes/diagnóstico por imagem
3.
Korean Journal of Radiology ; : 218-221, 2013.
Artigo em Inglês | WPRIM | ID: wpr-15366

RESUMO

We report the case in a 72-year-old man who presented with a right inguinal mass and with a one month history that was initially interpreted as an inguinal hernia. Ultrasonography (US) and computed tomography (CT) demonstrated a right inguinal mass, including myxoid and fat component, extending from the right spermatic cord to the right inguinal subcutaneous layer. Mass excision was performed, and the diagnosis turned out to be angiomyxolipoma. Angiomyxolipoma is a rare tumor and the preoperative diagnosis of this disease is very difficult. However, angiomyxolipoma of the spermatic cord should be considered in the differential diagnosis in patients with an irreducible inguinal mass. Imaging diagnosis, such as US and CT may help to make a preoperative diagnosis.


Assuntos
Idoso , Humanos , Masculino , Angiolipoma/patologia , Hérnia Inguinal/diagnóstico por imagem , Mixoma/patologia , Cordão Espermático/patologia , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler
4.
Korean Journal of Anesthesiology ; : 939-945, 1998.
Artigo em Coreano | WPRIM | ID: wpr-192191

RESUMO

Background: Cerebral palsy is due to static encephalopathy during perinatal period. Selective dorsal rhizotomy (SDR) involves selective division of posterior nerve roots to reduce spasticity and improve function in children with spastic cerebral palsy. Anesthesia during SDR must preserve muscle contraction in response to direct electrical stimulation of the dorsal nerve roots. We did this study to get the better management of anesthesia for SDR. Methods: Anesthetic records were reviewed for 16 patients who underwent SDR during January 1996 to August 1997. Demographic data; anesthetic drugs and doses; changes of vital signs and end tidal CO2; dorsal root stimulation; postoperative pain control were analysed. Results: The mean age of patients was 4.9+/-1.7 years old. The mean weight was 16.3+/-4.0 kg. The under 1 MAC concentration of isoflurane and 2~3 mcg/kg/hr fentanyl did not interfere with electrophysiologic monitoring. Esophageal temperature was increased significantly during electrical stimulation of dorsal roots. End tidal CO2 concentration had a tendency to increase after electrical stimulation too. Direct installation of 10~15 mcg/kg intrathecal morphine prior to dural closure, and postoperative 0.5 mcg/kg/hr fentanyl had a good postoperative analgesia without complication. Conclusions: Isoflurane and fentanyl during anesthesia, and intrathecal morphine with continuous infusion of fentany postoperatively are suggested a good anesthetic method for SDR.


Assuntos
Criança , Humanos , Analgesia , Anestesia , Anestésicos , Paralisia Cerebral , Estimulação Elétrica , Fentanila , Isoflurano , Morfina , Contração Muscular , Espasticidade Muscular , Dor Pós-Operatória , Rizotomia , Raízes Nervosas Espinhais , Sinais Vitais
5.
Journal of Korean Orthopaedic Research Society ; : 68-75, 1998.
Artigo em Coreano | WPRIM | ID: wpr-10397

RESUMO

Wear of polyethylene liner and osteolysis appear to be topical problems after long-term follow-up in total hip arthroplasty(THA). Age and activity of patients, manufacturing procedure of polyethylene liner, thickness of the liner, position of acetabular cup, and material of artificial femoral head have of effects on the degree of wear. In addition, conformity, congruency and micromotion between liner and metal cup are likely to be related to the wear. The purpose of this study is 1) to determine the stress caused by contact between metal and polyethylene components, 2) to evaluate the effects of conformity, congruency, and fixation between metal and polyethylene components, on contact stress in acetabular cups and 3) to identify the design parameters of the commercial acetabular cup within the constraints imposed by the overall functional requirements of total joint replacement. The specimens applied to six different commercial cups made in five companies. The methods was performed on dynamic test and static test to rely on load conditions, estimated the gap between the components through LM. The results showed H-G II cup had the most excellent congruency because of the narrowest interval between two components.


Assuntos
Humanos , Acetábulo , Cabeça , Quadril , Articulações , Osteólise , Polietileno
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA