Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Adicionar filtros








Intervalo de ano
1.
Japanese Journal of Cardiovascular Surgery ; : 142-146, 2022.
Artigo em Japonês | WPRIM | ID: wpr-924581

RESUMO

We report the case of a patient with severe tricuspid regurgitation and severe liver dysfunction who was successfully treated by tricuspid valve repair with spiral suspension and perioperative management of high cardiac output. The patient was a 77-year-old woman who presented with chronic atrial fibrillation with bradycardia (heart rate approximately 50 bpm). She had been diagnosed with severe tricuspid valve and mitral valve regurgitation at the age of 74. As her heart failure and hepatic failure grew worse, and hepatic encephalopathy also occurred, she was admitted to the hospital. Her Child-Pugh score for liver disease was Grade C at the preoperative assessment, suggesting that she was in the high-risk category for open heart surgery. Therefore, further medical treatment was required before selecting the surgical treatment. After the implantation of a pacemaker (VVI mode, 80 bpm), the cardiac output increased with a cardiac index of 5.17 L/min/m2 compared with 2.97 L/min/m2 prior to pacemaker implantation. Furthermore, the symptoms of heart failure improved and total bilirubin decreased from 3.9 mg/dl to 1.7 mg/dl, and surgery was performed. Tricuspid regurgitation was treated with spiral suspension, and mitral regurgitation due to annular dilation was treated with annuloplasty. Following the surgery, the cardiac index was maintained from 4.3 L/min/m2 to 5.8 L/min/m2 with central venous pressure below 10 mmHg by the assistance of intra-aortic balloon pumping. The patient was extubated 30 h after surgery, and was discharged on postoperative day 54. At the time of discharge, total bilirubin was 1.5 mg/dl. At 1.5 post-operative years, the patient is New York Heart Association functional Class II and tricuspid valve regurgitation is mild.

2.
Japanese Journal of Cardiovascular Surgery ; : 48-52, 2022.
Artigo em Japonês | WPRIM | ID: wpr-924537

RESUMO

A 41-years-old man with Marfan syndrome developed acute aortic dissection Stanford Type B. A new entry was located at the distal aortic arch. Medical treatment was given for a month, but the proximal descending aorta expanded to 50 mm. Because he had undergone partial arch replacement at the age of 36, thoracic endovascular aortic repair (TEVAR) using the synthetic graft as proximal landing zone was performed to close the entry. Six months after TEVAR, the false lumen around the stent graft disappeared. Distal stent graft-induced new entry (d-SINE) did not occur after TEVAR. Three years after TEVAR, we performed thoracoabdominal aortic replacement because of expansion of the residual false lumen without any complication. Endovascular therapy could be useful option for extensive aortic lesion even in Marfan syndrome.

3.
Japanese Journal of Cardiovascular Surgery ; : 61-64, 2021.
Artigo em Japonês | WPRIM | ID: wpr-873938

RESUMO

A 24-year-old man was admitted to another hospital due to fever and chest and back pain. Enhanced chest computed tomography showed an aneurysm between the distal aortic arch and left pulmonary artery. The patient was transferred to our hospital for surgery. Because of suspicion of an infectious ductus arteriosus aneurysm, antibiotic therapy was started. Urgent graft replacement of the descending aorta was performed on the third day due to the enlargement of the aneurysm. All blood cultures including the preoperative examination, and the aneurysmal culture were negative. The histopathological study showed non-specific inflammatory response with plasma cell, T lymphocyte, and B lymphocyte infiltrations. There was no evidence of infection. Eventually we diagnosed this patient as having a ductus arteriosus aneurysm with non-specific inflammation. The antibiotic therapy was terminated on postoperative day 10, and the postoperative course was uneventful.

4.
Japanese Journal of Cardiovascular Surgery ; : 76-78, 2017.
Artigo em Japonês | WPRIM | ID: wpr-378800

RESUMO

<p>An 82-year-old man was referred to our hospital for heart failure due to severe mitral regurgitation and severe tricuspid regurgitation. We performed mitral annuloplasty and tricuspid annuloplasty (TAP). Three weeks after surgery, he developed hemolytic anemia (HA). Transesophageal echocardiography revealed a defect in the left ventricular outflow tract that communicated directly with right atrium, and the jet was striking with the TAP prosthetic ring. HA was not controlled, so we performed re-operation. The defect was found in the atrioventricular membranous septum. The defect was closed and TAP was performed using an autologous pericardial roll again. We report a rare case of acquired left ventricular to right atrium communication after TAP.</p>

5.
Japanese Journal of Cardiovascular Surgery ; : 159-163, 2011.
Artigo em Japonês | WPRIM | ID: wpr-362085

RESUMO

A 16-year-old boy had a motorcycle accident and was given a diagnosis of blunt aortic injury (BAI) by contrast computed tomography (CT), complicated by diffuse brain injury, lung contusions and blunt liver injury. Despite conservative treatment his anemia worsened and further CT images revealed mediastinal hematoma. It was difficult to perform cardiopulmonary bypass with systemic heparinization because of his multiple injuries and therefore decided to perform endovascular stentgrafting. Aortography revealed that the proximal stent-graft landing zone to be very small, and therefore it was necessary to the cover left common carotid artery. Before stentgrafting, we performed a right subclavian artery-left common carotid artery bypass to attain a sufficient proximal landing zone, and stentgrafting was successful. We concluded that endovascular stentgrafting is an effective initial treatment for BAI complicated with multiple injuries. However, endovascular stentgrafting for BAI has some limitations because of the morphologic and anatomical characteristics of the thoracic aorta in cases of BAI. It is therefore important to perform endovascular stentgrafting for BAI on a case-by-case basis.

6.
Japanese Journal of Cardiovascular Surgery ; : 425-428, 2004.
Artigo em Japonês | WPRIM | ID: wpr-367022

RESUMO

We present a successfully treated case of re-operation for aortic valvular stenosis caused by implantation of a stentless prosthesis using oversizing sub-coronary insertion in a young woman. The 17-year-old Japanese woman received aortic valve replacement (AVR) with a 21mm Freestyle stentless porcine valve (Medtronic Inc.), using the oversizing modified sub-coronary insertion because of infectious endocarditis 12 years previously at another hospital. Just after the operation, she suffered severe heart failure. At 16 years old, since a cardiac murmur and dyspnea on effort appeared, and she presented severe heart failure due to significant aortic valvular stenosis with a mean aortic valve gradient 115mmHg, we performed aortic valve re-replacement (ATS AP 18mm) with an aortic root enlargement procedure. Intraoperative findings suggested that the oversizing technique was related to aortic valvular stenosis. The postoperative course has been uneventful.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA