Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Braz. oral res ; 22(2): 145-150, 2008. tab
Artigo em Inglês | LILACS | ID: lil-485954

RESUMO

The aim of this investigation was to monitor metronidazole concentrations in the gingival crevicular fluid (GCF) collected from periodontal pockets of dogs after treatment with an experimental 15 percent metronidazole gel. Five dogs had periodontitis induced by cotton ligatures placed subgingivally and maintained for a 30-day period. After the induction period, only pockets with 4 mm or deeper received the gel. Each pocket was filled up to the gingival margin by means of a syringe with a blunt-end needle. GCF was collected in paper strips and quantified in an electronic device before and after 15 minutes, 1 h, 6 h, 24 h and 48 h of gel administration. The GCF samples were assayed for metronidazole content by means of a high performance liquid chromatography method. Concentrations of metronidazole in the GCF of the 5 dogs (mean ± SD, in µg/mL) were 0 ± 0 before gel application and 47,185.75 ± 24,874.35 after 15 minutes, 26,457.34 ± 25,516.91 after 1 h, 24.18 ± 23.11 after 6 h, 3.78 ± 3.45 after 24 h and 3.34 ± 5.54 after 48 h. A single administration of the 15 percent metronidazole gel released the drug in the GCF of dogs in levels several-fold higher than the minimum inhibitory concentration for some periodontopathogens grown in subgingival biofilms for up to one hour, but metronidazole could be detected in the GCF at least 48 hours after the gel application.


Assuntos
Animais , Cães , Feminino , Masculino , Anti-Infecciosos/análise , Líquido do Sulco Gengival/química , Metronidazol/análise , Periodontite/tratamento farmacológico , Anti-Infecciosos/administração & dosagem , Avaliação Pré-Clínica de Medicamentos , Géis , Metronidazol/administração & dosagem , Bolsa Periodontal/tratamento farmacológico , Periodontite/induzido quimicamente
2.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 43(1): 97-103, jan.-mar. 2007. tab, ilus
Artigo em Inglês | LILACS | ID: lil-451935

RESUMO

Mesalamine (5-aminosalicylic acid, 5-ASA) is used because of its local effects in the treatment of inflammatory bowel disease. Therefore, the aims of this work were to compare and validate three analytical methods for the quality control of commercial coated tablets containing 5-ASA: high performance liquid chromatography (HPLC), 1,1-diphenyl-2-picrylhydrazyl radicals (DPPH•) and nitrosation. The parameters linearity, precision and accuracy were studied in this work. HPLC with ultraviolet detection at 254 nm was carried out with a C18 column and a mobile phase constituted of 30 mmol/L monobasic phosphate buffer (pH 7.0) and methanol (70:30; v/v), with 25 percent tetrabutylammonium hydrogen sulphate. The DPPH• method was performed at 517 nm and using 100 mmol/L acetate buffer, pH 5.5, ethanol and 250 æmol/L ethanolic solution of DPPH•. The nitrosation method was accomplished by using a platinum electrode and standard 0.1 mol/L sodium nitrite as titrant solution. Repeatability (intra-day) and intermediate precision (inter-day), expressed as RSD, were lower than 3 percent. The experimental recoveries were between 72.5 and 99.9 percent. Statistical analysis by one-way ANOVA, followed by the multiple comparison test of Bonferroni showed no significant difference among the three methods. All proposed methods can be used for the reliable quantitation of 5-ASA in pharmaceutical dosage forms.


Mesalazina (ácido 5-aminosalicílico, 5-ASA) é utilizado devido seu efeito local no tratamento de doença inflamatória intestinal. Assim, o objetivo deste trabalho foi comparar e validar três métodos analíticos para o controle de qualidade de comprimidos comerciais revestidos contendo 5-ASA: cromatografia líquida de alta eficiência (CLAE), radical 1,1-difenil-2-picril-hidrazil (DPPH•) e nitrosação. Os parâmetros linearidade, precisão e exatidão foram estudados neste trabalho. CLAE com detecção ultravioleta em 254 nm foi realizada utilizando coluna C18 e a eluição em fase móvel constituída de tampão fosfato monobásico 30 mmol/L (pH 7,0) e metanol (70:30; v/v), com 25 por cento de sulfato hidrogênio de tetrabutilamônio. Para o método de DPPH• utilizou-se tampão acetato 100 mmol/L, pH 5,5, álcool etílico e 250 æmol/L solução etanólica de DPPH• a 517 nm. Para o método de nitrosação utilizou-se um eletrodo de platina e um padrão de nitrito de sódio 0.1 mol/L como solução titulante. Repetibilidade (intra-dia) e precisão intermediária (inter-dia), expressado como DPR, foi menor que 3 por cento. A recuperação experimental foi entre 72,5 e 99,9 por cento. Análise estatística por "one-way" ANOVA, seguida de comparação múltipla do teste de Bonferroni, não mostrou significância entre os três métodos. Os métodos propostos podem ser usados para análise quantitativa do5-ASA em formas farmacêuticas.


Assuntos
Mesalamina/análise , Preparações Farmacêuticas , Cromatografia Líquida/métodos , Nitrosação , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA