Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
The Journal of Korean Academy of Prosthodontics ; : 211-221, 2022.
Artigo em Inglês | WPRIM | ID: wpr-926946

RESUMO

Implant placement may be restricted by anatomical and/or financial limitations in restoring a completely edentulous arch, or the patients’ unwillingness to have extensive surgical procedures. Implant assisted removable partial dentures (IARPD) in combination with anterior fixed implant prostheses can be proposed as an alternative treatment option for the restoration of a completely edentulous arch. In this case, a 56-year-old female patient who has a fully edentulous maxilla opposed by partially edentulous mandible was treated. The treatment option for the maxilla consisted of an implant-assisted removable partial denture supported by four anterior fixed implant prostheses. The mandible was restored with 8 anterior fixed partial dentures and posterior fixed implant-supported prostheses.Long-term follow-up and supportive periodontal treatment were performed for 9years, and the patient was satisfied with the overall appearance as well as masticatory function.

2.
The Journal of Korean Academy of Prosthodontics ; : 82-89, 2014.
Artigo em Coreano | WPRIM | ID: wpr-86183

RESUMO

PURPOSE: The purpose of this study was to observe the change of viscoelastic properties of dental resin cements during polymerization. MATERIALS AND METHODS: Six commercially available resin cement materials (Clearfil SA luting, Panavia F 2.0, Zirconite, Variolink N, RelyX Unicem clicker, RelyX U200) were investigated in this study. A dynamic oscillation-time sweep test was performed with AR1500 stress controlled rheometer at 32degrees C. The changes in shear storage modulus (G'), shear loss modulus (G"), loss tangent (tan delta) and displacement were measured for twenty minutes and repeated three times for each material. The data were analyzed using one-way ANOVA and Tukey's post hoc test (alpha=0.05). RESULTS: After mixing, all materials demonstrated an increase in G' with time, reaching the plateau in the end. RelyX U200 demonstrated the highest G' value, while RelyX Unicem (clicker type) and Variolink N demonstrated the lowest G' value at the end of experimental time. Tan delta was maintained at some level and reached the zero at the starting point where G' began to increase. The tan delta and displacement of the tested materials showed similar pattern in the graph within change of time. The displacement of all 6 materials approached to zero within 6 minutes. CONCLUSION: Compared to other resin cements used in this study, RelyX U200 maintained plastic property for a longer period of time. When it completed the curing process, RelyX U200 had the highest stiffness. It is convenient for clinicians to cement multiple units of dental prostheses simultaneously.


Assuntos
Prótese Dentária , Plásticos , Polimerização , Polímeros , Cimentos de Resina , Resinas Sintéticas , Triacetonamina-N-Oxil
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA