Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Adicionar filtros








Intervalo de ano
1.
Yonsei Medical Journal ; : 233-242, 2023.
Artigo em Inglês | WPRIM | ID: wpr-977432

RESUMO

Purpose@#Glioblastoma (GBM) is an intractable disease for which various treatments have been attempted, but with little effect.This study aimed to measure the effect of photodynamic therapy (PDT) and sonodynamic therapy (SDT), which are currently being used to treat brain tumors, as well as sono-photodynamic therapy (SPDT), which is the combination of these two. @*Materials and Methods@#Four groups of Sprague-Dawley rats were injected with C6 glioma cells in a cortical region and treated with PDT, SDT, and SPDT. Gd-MRI was monitored weekly and 18F-FDG-PET the day before and 1 week after the treatment. The acoustic power used during sonication was 5.5 W/cm2 using a 0.5-MHz single-element transducer. The 633-nm laser was illuminated at 100 J/cm2 . Oxidative stress and apoptosis markers were evaluated 3 days after treatment using immunohistochemistry (IHC): 4-HNE, 8-OhdG, and Caspase-3. @*Results@#A decrease in tumor volume was observed in MRI imaging 12 days after the treatment in the PDT group (p<0.05), but the SDT group showed a slight increase compared to the 5-Ala group. The high expression rates of reactive oxygen species-related factors, such as 8-OhdG (p<0.001) and Caspase-3 (p<0.001), were observed in the SPDT group compared to other groups in IHC. @*Conclusion@#Our findings show that light with sensitizers can inhibit GBM growth, but not ultrasound. Although SPDT did not show the combined effect in MRI, high oxidative stress was observed in IHC. Further studies are needed to investigate the safety parameters to apply ultrasound in GBM.

2.
Korean Journal of Dental Materials ; (4): 1-14, 2021.
Artigo em Inglês | WPRIM | ID: wpr-901911

RESUMO

The purpose of this study was to investigate the effect of glazing treatment of multi-colored zirconia disc and lithium disilicate block on the optical properties. From an Ultra Translucent Multi-Layered (UTML) disc containing 50% cubic crystal and a lithium disilicate-based Amber Mill Direct (AMD) block, the 1.2 mm thick specimens of the upper layer (T), the center (M), and the lower layer (B) were prepared. Three types of paste glaze of InSync Glaze Paste, IPS E.max Ceram Glaze Paste, and Amber Ceram G7 Glaze Paste were applied and fired to a uniform thickness on the surface of the specimen. CIE L * , a * , b * values were measured using a spectrophotometer and contrast and translucency were calculated. The bonding interface with the glaze layer was observed using HR FE-SEM. In the glazed groups, L * value increased, but a * value and b * value decreased. The translucency value measured in the untreated group was statically higher in the AMD groups than in UTML groups (P0.05), but significantly decreased compared to the untreated group after glazing treatment in the AMD group (P<0.05). The contrast ratios generally increased after glaze treatment compared to the untreated group. Since the glaze treatment can affect the optical properties of ceramic restorations, the choice of glaze should be considered important for the desired color by the dental technician.

3.
Korean Journal of Dental Materials ; (4): 1-14, 2021.
Artigo em Inglês | WPRIM | ID: wpr-894207

RESUMO

The purpose of this study was to investigate the effect of glazing treatment of multi-colored zirconia disc and lithium disilicate block on the optical properties. From an Ultra Translucent Multi-Layered (UTML) disc containing 50% cubic crystal and a lithium disilicate-based Amber Mill Direct (AMD) block, the 1.2 mm thick specimens of the upper layer (T), the center (M), and the lower layer (B) were prepared. Three types of paste glaze of InSync Glaze Paste, IPS E.max Ceram Glaze Paste, and Amber Ceram G7 Glaze Paste were applied and fired to a uniform thickness on the surface of the specimen. CIE L * , a * , b * values were measured using a spectrophotometer and contrast and translucency were calculated. The bonding interface with the glaze layer was observed using HR FE-SEM. In the glazed groups, L * value increased, but a * value and b * value decreased. The translucency value measured in the untreated group was statically higher in the AMD groups than in UTML groups (P0.05), but significantly decreased compared to the untreated group after glazing treatment in the AMD group (P<0.05). The contrast ratios generally increased after glaze treatment compared to the untreated group. Since the glaze treatment can affect the optical properties of ceramic restorations, the choice of glaze should be considered important for the desired color by the dental technician.

4.
Korean Journal of Dental Materials ; (4): 211-220, 2020.
Artigo em Inglês | WPRIM | ID: wpr-901891

RESUMO

The purpose of this study was to evaluate the effect of the reaction between investment material and zirconia on the strength of zirconia in the application of heat-pressing method. Sixty specimens were cut (24 mm×4 mm×0.5 mm) into plates from Zirtooth ™ Multi O-9814 block (∅98×14T, HASS, Gangwondo, Korea) and sintered at 1450℃. Specimens were divided into 6 subgroups according to the depending on the investement material; (a) UN group (Control), (b) PH group (Prime vest HS), (c) CP group (Calibra-press), (d) BV group (BC-Vest), (e) MH group (Microstar-HS), (f) F1 group (Formula 1). Five investment materials were buried according to the procedure recommended by the manufacturer and left at room temperature for 30 minutes. The investment mold was dried and maintained at an elevated temperature of 850℃ for 50 minutes. Then, Amber Lisi-POZ LT (HASS) was placed in a thermoformed electric furnace (Programat EP3000/G2, Ivoclar Vivadent, Schaan, Liechtenstein) together with the mold, heated to 915℃ at an elevation temperature of 45℃/min, and moored for 15 minutes. The specimens were loaded to fracture in a universal testing machine and the fracture surface was examined by a field-emission scanning electron microscopy (FE-SEM). The surface of the zirconia specimen with the investment material was analyzed by energy dispersive X-ray spectroscopy (EDS). The 3-point flexural strength test showed the highest value (1265.5 MPa) in the UN group and the lowest value (756.1 MPa) in the F1 group. As a result of EDS analysis, the largest amount of Si was detected in the F1 group, and the most interfacial changes occurred as a result of FE-SEM analysis. It was concluded that when the zirconia is buried with the investment material and the heat press molding is performed, the state of the interface is changed due to the investment material at the bonding interface while the strength is lowered.

5.
Korean Journal of Dental Materials ; (4): 211-220, 2020.
Artigo em Inglês | WPRIM | ID: wpr-894187

RESUMO

The purpose of this study was to evaluate the effect of the reaction between investment material and zirconia on the strength of zirconia in the application of heat-pressing method. Sixty specimens were cut (24 mm×4 mm×0.5 mm) into plates from Zirtooth ™ Multi O-9814 block (∅98×14T, HASS, Gangwondo, Korea) and sintered at 1450℃. Specimens were divided into 6 subgroups according to the depending on the investement material; (a) UN group (Control), (b) PH group (Prime vest HS), (c) CP group (Calibra-press), (d) BV group (BC-Vest), (e) MH group (Microstar-HS), (f) F1 group (Formula 1). Five investment materials were buried according to the procedure recommended by the manufacturer and left at room temperature for 30 minutes. The investment mold was dried and maintained at an elevated temperature of 850℃ for 50 minutes. Then, Amber Lisi-POZ LT (HASS) was placed in a thermoformed electric furnace (Programat EP3000/G2, Ivoclar Vivadent, Schaan, Liechtenstein) together with the mold, heated to 915℃ at an elevation temperature of 45℃/min, and moored for 15 minutes. The specimens were loaded to fracture in a universal testing machine and the fracture surface was examined by a field-emission scanning electron microscopy (FE-SEM). The surface of the zirconia specimen with the investment material was analyzed by energy dispersive X-ray spectroscopy (EDS). The 3-point flexural strength test showed the highest value (1265.5 MPa) in the UN group and the lowest value (756.1 MPa) in the F1 group. As a result of EDS analysis, the largest amount of Si was detected in the F1 group, and the most interfacial changes occurred as a result of FE-SEM analysis. It was concluded that when the zirconia is buried with the investment material and the heat press molding is performed, the state of the interface is changed due to the investment material at the bonding interface while the strength is lowered.

6.
Journal of Korean Neurosurgical Society ; : 6-11, 2015.
Artigo em Inglês | WPRIM | ID: wpr-166152

RESUMO

OBJECTIVE: Neuropathic pain causes patients feel indescribable pain. Deep Brain Stimulation (DBS) is one of the treatment methods in neuropathic pain but the action mechanism is still unclear. To study the effect and mechanism of analgesic effects from DBS in neuropathic pain and to enhance the analgesic effect of DBS, we stimulated the ventral posterolateral nucleus (VPL) in rats. METHODS: To observe the effect from VPL stimulation, we established 3 groups : normal group (Normal group), neuropathic pain group (Pain group) and neuropathic pain+DBS group (DBS group). Rats in DBS group subjected to electrical stimulation and the target is VPL. RESULTS: We observed the behavioral changes by DBS in VPL (VPL-DBS) on neuropathic pain rats. In our study, the pain score which is by conventional test method was effectively decreased. In specific, the time of showing withdrawal response from painful stimulation which is not used measuring method in our animal model was also decreased by DBS. CONCLUSION: The VPL is an effective target on pain modulation. Specifically we could demonstrate changes of pain response duration which is not used, and it was also significantly meaningful. We thought that this study would be helpful in understanding the relation between VPL-DBS and neuropathic pain.


Assuntos
Animais , Humanos , Ratos , Estimulação Encefálica Profunda , Estimulação Elétrica , Modelos Animais , Neuralgia , Núcleos Ventrais do Tálamo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA