Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Tissue Engineering Research ; (53): 1221-1226, 2016.
Artigo em Chinês | WPRIM | ID: wpr-484855

RESUMO

BACKGROUND:Knee-parameter measurements play an important role in the designing of the knee prosthesis. Currently, we have more and more research of the total knee replacement, while uni-condylar knee replacement study is few. OBJECTIVE: To obtain the parameters of the normal femoral condyles and explore its correlation with osteotomy and prosthesis design of the knee joint during uni-condylar knee replacement. METHODS: Normal knee joints of 60 cases (60 knees) were selected. We measured the parameters by using thin-section CT scan and post-processing techniques, including arc diameter of the lowest point of the femoral condyle on the coronal plane, arc diameter of the distal point of the posterior condyle of the femur on the transverse plane, arc diameter of the distal point of the posterior condyle of the femur on the sagittal plane, and arc diameter of the lowest point of the femoral condyle on the sagittal plane, and analyzed the correlation with sex and height. RESULTS AND CONCLUSION:The diameter of the arc that passes through the lowest point of femoral medial condyle in the coronal plane was (42.685±1.389) mm. The diameter of the arc that passes through the farthest point of posterior of femoral medial condyle in the cross-section was (42.732±1.440) mm. The diameter of the arc that passes through the lowest point of femoral medial condyle on the sagittal plane was (45.473±1.332) mm. The diameter of the arc that passes through the farthest point of posterior of femoral medial condyle on the sagittal plane was (42.587±1.446) mm. The results illustrate that knee condyle related parameters were positively correlated with height. Parameters in males were significantly greater than in females. The diameter of the arc that passes through the lowest point of femoral medial condyle on the sagittal plane was significantly larger than that of the farthest point of femoral posterior medial condyle on the sagittal plane (P < 0.001). There was no significant difference among the diameter of the arc that passes through the lowest point of femoral medial condyle on the coronal plane, the diameter of the arc that passes through the farthest point of posterior of femoral medial condyle on the cross-section and that of the farthest point of femoral posterior medial condyle on the sagittal plane.

2.
Chinese Journal of Biochemical Pharmaceutics ; (6): 5-9, 2015.
Artigo em Chinês | WPRIM | ID: wpr-463889

RESUMO

Objective To obtain monoclonal antibodies ( mAbs ) against neutrophil gelatinase-associated lipocalin ( NGAL ) and a chemiluminescense immune quantification assay based one paired mAbs.Methods Six-to-eight weeks old female BALB/c mice were immunized with the purified recombinant human NGAL antigen( rhNGAL) that was produced by the Escherichia coil expression system.The spleen was fused with hybridoma for screening anti-NGAL monoclonal antibodies by indirect ELISA.Western blot was implemented to identify the reactivity with native NGAL. Results The rhNGAL antigen was found to form disulfide cross-linked dimers and present excellent immunogenicity.The reaction titer of the immune serum of NGAL immunized mice was about 106.Thirty mAbs were screened by indirect ELISA, hereinto;the EC50 values of mAb23C12 and 38D10 were 0.034 g/mL, 0.022 g/mL respectively.The antibodies pair, 38D10/23C12-SAE labeled with AcridiniumEster(AE), were shown to work well in chemiluminescense immune response quantitative detection which was screened by NGAL standardand clinical urine samples.This detection can resolve positive and negative samples with a statistically significant difference (P<0.0001).And the correlation coefficient R2between NGAL quantitative results and that of the Abbott's NGAL chemiluminescence immune assay kit was greater than 0.97.The detection linear range was 10-1500 ng/mL, analytical sensitivity of the method was 0.63 ng/mL.Conclusion Highly purified rhNGAL antigen and specific anti-NGAL monoclonal antibodies are generated in this study.The detection capability of method is comparable with that of the international commercial kit.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA