Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Surgery ; (12): 219-222, 2022.
Artigo em Chinês | WPRIM | ID: wpr-935603

RESUMO

Pancreaticojejunostomy is the most common anastomosis following pancreaticoduodenectomy and middle pancreatectomy. The detailed surgical technics of pancreaticojejunostomy vary dramatically, but none of them can achieve zero fistula rate. In recent years,with the development of new surgical concept,application of new surgical technology, high-tech materials and instruments,the incidence of pancreatic fistula has decreased. At the same time,researches on investigating the risk factors of pancreaticojejunostomy are gradually deepening. Based on years of surgical experience on pancreaticojejunostomy and current literatures, this paper analyzes the factors affecting the effect of pancreaticojejunostomy, such as the patient's basic physical state,pancreatic texture and diameter of the pancreatic duct,pathology and course of the disease,surgical technology and perioperative management,and summarizes six technical principles for pancreaticojejunostomy to be shared with surgical comrades:appropriate tension,protection of blood supply,hermetic closure of pancreatic section,accurate connection of pancreatic duct and intestinal mucosa,individualization,learning and accumulation of experience.


Assuntos
Humanos , Anastomose Cirúrgica/efeitos adversos , Fístula Pancreática/prevenção & controle , Pancreaticoduodenectomia/efeitos adversos , Pancreaticojejunostomia/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento
2.
Chinese Medical Journal ; (24): 3553-3556, 2013.
Artigo em Inglês | WPRIM | ID: wpr-354436

RESUMO

<p><b>BACKGROUND</b>Due to lack of point-of-care testing, the use of low-molecular-weight heparin (LMWH) therapy in some special patients is restricted. This study was designed to explore the effects of LMWH on clot rate (CR) and activated clotting time (ACT), and to search for an appropriate method for bedside monitoring of anticoagulant activity of LMWH.</p><p><b>METHODS</b>Thirty-two healthy volunteers were selected from the staff of Beijing Tongren Hospital. CR and ACT were measured with different reagents (glass beads, diatomite, kaolin and magnetic bar) on blood samples spiked with increasing concentrations of LMWH (dalteparin, 0.2-1.8 IU/ml). Correlations between concentrations of LMWH and values of CR and ACT were analysed based on the data obtained and regression analysis was performed to establish a regression equation.</p><p><b>RESULTS</b>With the increase in doses of dalteparin, CR values reduced gradually. The values of CR of four reagents (glass beads, diatomite, kaolin and magnetic bar) were 20.4-4.5 IU/min, 27.4-6.9 IU/min, 27.5-7.9 IU/min and 7.8-0.1 IU/min respectively and an linear relationship was observed between the CR values and dalteparin concentrations (P < 0.05). The values of ACT were 173-615 seconds, 130-270 seconds, 123-226 seconds, 337-1411 seconds respectively, which showed a linear regression between the ACT values and dalteparin concentrations (P < 0.01). Differences in slope of the regression curves of ACT were observed with all the reagents tested (glass beads 248.2 s/IU, diatomite 74.8 s/IU, kaolin 58.2 s/IU and magnetic bar 1112.2 s/IU, P < 0.01). While the minimum concentration of dalteparin was 0.2 IU/ml, 0.4 IU/ml, 1.4 IU/ml and 0.2 IU/ml separately, the ACT values of the four coagulants (glass beads, diatomite, kaolin and magnetic bar) were beyond the normal limit and showed a noticeable increase respectively (P < 0.01).</p><p><b>CONCLUSIONS</b>This study showed that there was an excellent linear relationship between the CR and ACT values and dalteparin concentrations for all the four reagents (glass beads, diatomite, kaolin and magnetic bar) in vitro. The sensitivity of different coagulation reagents to LMWH different. Choosing a suitable reagent, both CR and ACT were possible to be used as a convenient bedside test for LMWH.</p>


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anticoagulantes , Farmacologia , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Heparina de Baixo Peso Molecular , Farmacologia
3.
Chinese Medical Journal ; (24): 1199-1202, 2009.
Artigo em Inglês | WPRIM | ID: wpr-292741

RESUMO

<p><b>BACKGROUND</b>Although low-molecular-weight heparin has replaced unfractionated heparin to become the primary anticoagulation drug for treatment of acute coronary syndrome, there is no convenient bedside monitoring method. We explored the best laboratory monitoring method of low-molecular-weight heparins (enoxaparin, dalteparin, and nadroparin) by use of the Sonoclot coagulation analyzer to monitor the activated clotting time.</p><p><b>METHODS</b>A total of 20 healthy volunteers were selected and 15 ml of fasting venous blood samples were collected and incubated. Four coagulants, kaolin, diatomite, glass bead, and magnetic stick, were used to determine the activated clotting time of the low-molecular-weight heparins at different in vitro anti-Xa factor concentrations. A correlation analysis was made to obtain the regression equation. The activated clotting time of the different low-molecular-weight heparins with the same anti-Xa factor concentration was monitored when the coagulant glass beads were applied.</p><p><b>RESULTS</b>The activated clotting time measured using the glass beads, diatomite, kaolin, and magnetic stick showed a linear correlation with the concentration of nadroparin (r = 0.964, 0.966, 0.970, and 0.947, respectively). The regression equation showed that the linear slopes of different coagulants were significantly different (glass beads 230.03 s/IU, diatomite 89.91 s/IU, kaolin 50.87 s/IU, magnetic stick could not be calculated). When the concentration of the anti-Xa factor was the same for different low-molecular-weight heparins, the measured activated clotting time was different after the application of the glass bead coagulant.</p><p><b>CONCLUSIONS</b>The glass bead coagulant is most feasible for monitoring the in vitro anticoagulation activity of nadroparin. The different effects of different low-molecular-weight heparins on the activated clotting time may be related to the different anti-IIa activities.</p>


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anticoagulantes , Farmacologia , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Coagulantes , Farmacologia , Vidro , Heparina de Baixo Peso Molecular , Farmacologia , Caulim , Farmacologia , Nadroparina , Farmacologia
4.
Journal of Southern Medical University ; (12): 675-677, 2006.
Artigo em Chinês | WPRIM | ID: wpr-282948

RESUMO

<p><b>OBJECTIVE</b>To explore the expression of transforming growth factor beta1 (TGFbeta1) and its type I receptors activin-like kinase 1 (ALK1) and ALK5 mRNA in the development of brain arteriovenous malformation (BAVM).</p><p><b>METHODS</b>The mRNA expressions of TGFbeta1, ALK1and ALK5 were detected with semiquantitative RT-PCR in patients with BAVM.</p><p><b>RESULTS</b>The expressions of TGFbeta1 and ALK5 mRNA increased significantly in BAVM, and their relative expression quantity were 0.777-/+0.047 and 0.585-/+0.074, respectively. However, ALK1 mRNA expression declined significantlies with a relative expression of 0.173-/+0.044 in comparison with the control group (0.720-/+0.098, P<0.01).</p><p><b>CONCLUSION</b>The balance of TGFbeta1 and its type I receptors ALK1 and ALK5 mRNA expressions may play important role in the development of BAVM.</p>


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Receptores de Activinas Tipo II , Genética , Encéfalo , Metabolismo , Patologia , Expressão Gênica , Malformações Arteriovenosas Intracranianas , Genética , Proteínas Serina-Treonina Quinases , Genética , RNA Mensageiro , Genética , Receptores de Fatores de Crescimento Transformadores beta , Genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Fator de Crescimento Transformador beta1 , Genética
5.
Chinese Journal of Medical Instrumentation ; (6): 259-264, 2002.
Artigo em Chinês | WPRIM | ID: wpr-344283

RESUMO

Here in this paper introduced is an analysis system for X-ray cephalometry developed through Windows platform,which includes three parts: data input, cephalometry analysis & calculation, and display & printing of diagnostic results. It has been applied in orthodontic department of Stomatological Hospital of the Fourth Military Medical University, and it is quite convenient for doctors' cephalometry diagnosis.


Assuntos
Humanos , Cefalometria , Computadores , Sistemas Computadorizados de Registros Médicos , Ortodontia , Métodos , Intensificação de Imagem Radiográfica , Radiografia , Software
6.
Chinese Journal of Medical Instrumentation ; (6): 170-217, 2002.
Artigo em Chinês | WPRIM | ID: wpr-344264

RESUMO

The paper introduces four kinds of 2450 MHz antennas including noninsulted (bare), insulated-open-tip (I.O.T.), dipole-type and sleeve invasive microwave ones. The comparison between the antennas' hyperthermia performances in the muscle tissue phantom made by specific absorption rate (SAR) shows that the sleeve antenna is the best. It has a bigger heating range and a changeless shape and is independent of the inserting depth.


Assuntos
Humanos , Desenho de Equipamento , Estudos de Avaliação como Assunto , Hipertermia Induzida , Micro-Ondas , Usos Terapêuticos , Modelos Biológicos , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA