Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Acta Academiae Medicinae Sinicae ; (6): 331-334, 2016.
Artigo em Inglês | WPRIM | ID: wpr-289860

RESUMO

Objective To evaluate the diagnostic value of high-frequency ultrasound in the diagnosis of supinator syndrome (SD). Methods Ten patients with supinator syndrome (SD group) and 20 healthy volunteers (control group) underwent ultrasonographic examination. Axial and long-axis views of the radial nerve were taken where the nerves enters the supinator muscle entrance. The maximum transverse diameter and anteroposterior diameter were also measured. Results High-frequency ultrasound clearly revealed the images and course of radial nerve deep branch in two groups. The SD group had swollen nerves and the maximum transverse diameter and anteroposterior diameter were (3.50?0.39)mm and (4.30?0.47)mm,respectively,which were significantly larger than in the control group [(1.10?0.17)mm,t=-29.67,P=0.00;(1.00?0.16)mm,t=-36.72,P=0.00). The causes (including synovial cyst nearby and radial artery recurrent branch) of nerve entrapment were revealed directly in 4 patients in SD group. Conclusions High-frequency ultrasound can clearly display the radial nerve deep branch around the elbow joint. SD patients have swollen nerves at the entrance of the supinator muscle,where the diameters of these nerves are abnormally enlarged.


Assuntos
Humanos , Estudos de Casos e Controles , Articulação do Cotovelo , Diagnóstico por Imagem , Voluntários Saudáveis , Síndromes de Compressão Nervosa , Diagnóstico por Imagem , Nervo Radial , Diagnóstico por Imagem , Neuropatia Radial , Diagnóstico por Imagem , Ultrassonografia
2.
Acta Academiae Medicinae Sinicae ; (6): 99-103, 2012.
Artigo em Chinês | WPRIM | ID: wpr-352945

RESUMO

<p><b>OBJECTIVE</b>To investigate the feasibility and clinical value of intraoperative ultrasonography (IOUS) in thoracic spinal decompression surgery.</p><p><b>METHODS</b>Ten patients with confirmed thoracic spinal stenosis underwent thoracic spinal decompression in our center from August 2009 to December 2010. The appearance of the compressed section of spinal cord was observed with IOUS. Before and after the decompression operation, the diameters of dural sac and the spinal cord were recorded respectively. The location and nature of the compression-causing mass were confirmed.</p><p><b>RESULTS</b>IOUS clearly showed the shape of the normal and the compressed sections of dural sac and spinal cord. In the 14 thoracic spinal cord sections of these 10 patients, the anteroposterior diameter, horizontal diameter, and their ratio were bigger than those before decompression. The values of anteroposterior diameter and anteroposterior/horizontal diameter ratio showed significant differences(the P value of dural sac anteroposterior diameter comparison was 0.008, which of spinal cord was 0.007; the P values of these two structures ratio comparison were both 0.002 before and after decompression), while the horizontal diameter presented no significant differences (the P values of both structures were 0.270 and 0.195 respectively before and after decompression).</p><p><b>CONCLUSIONS</b>IOUS can clearly show the morphological changes of the dural sac and spinal cord before and after the decompression. In addition, it helps surgeons to locate and specify the nature of the compression-causing mass on the ventral side of dural sac. Furthermore, IOUS can suggest whether the decompression is sufficient in a real-time manner.</p>


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Descompressão Cirúrgica , Monitorização Intraoperatória , Métodos , Medula Espinal , Diagnóstico por Imagem , Estenose Espinal , Diagnóstico por Imagem , Cirurgia Geral , Vértebras Torácicas , Resultado do Tratamento , Ultrassonografia
3.
Acta Academiae Medicinae Sinicae ; (6): 96-102, 2010.
Artigo em Chinês | WPRIM | ID: wpr-301586

RESUMO

<p><b>OBJECTIVE</b>To evaluate the usefulness of contrast-enhanced ultrasonography (CEUS) in the diagnosis of biliary diseases.</p><p><b>METHODS</b>CEUS was performed in 57 patients with biliary diseases. The contrast enhancement characteristics and the morphologic features were observed. The ultrasonographic results were compared with those obtained through conventional 2-D ultrasound (2D-US), color Doppler flow ultrasound (CDFI), and clinical, surgical, and laboratory findings. In some cases, the ultrasonographic results were also compared with those obtained from contrast-enhanced computed tomography (CECT).</p><p><b>RESULTS</b>The diagnostic accuracy of 2D-US combined with CEUS was significantly higher than that of 2D-US combined with CDFI 87.7% vs 71.9%; chi(2) = 4.41, P < 0.05). CEUS clearly showed the presence/absence of blood supply in biliary lesions and offered real-time imaging of the microcirculation perfusion in the lesions. It also offered useful information to differentiate biliary tumors from stones, bile mud, and/or blood clots. It distinctly displayed the size and contour of the lesions as well as the infiltrated range, depth, and the involved area. However, CEUS is most useful in reflecting blood perfusion patterns; it had limited value in differentiating the malignancies of polypoid lesions. The diagnostic accuracy (87.0% vs 91.3%;chi(2) = 0. 45, P > 0.05) and the size and range of the lesions displayed (0.4-6.2 cm vs 0.4-6.0 cm, P = 0.721) were not significantly different between CEUS and CECT.</p><p><b>CONCLUSION</b>CEUS is a useful tool in the routine ultrasonography of biliary diseases.</p>


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Doenças Biliares , Diagnóstico por Imagem , Sensibilidade e Especificidade , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA