Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Orthopaedic Trauma ; (12): 657-662, 2023.
Artigo em Chinês | WPRIM | ID: wpr-992763

RESUMO

Objective:To compare the effects of anterograde elastic stable intramedullary nailing (ESIN-A), retrograde K-wires fixation (KW-R) and retrograde precision shaping of elastic stable intramedullary nailing (ESIN-RPS) in the treatment of fractures of distal radial metaphyseal diaphyseal junction (DRMDJ) in children.Methods:A retrospective study was conducted to analyze the data of 112 eligible children with DRMDJ fracture who had been treated at Department of Orthopedics, Children's Hospital, Anhui Medical University and Department of Orthopedics, The People's Hospital of Fuyang City,Anhui Medical University, from January 2016 to May 2022. There were 64 males and 48 females, with an age of (8.4±2.3) years. The children were divided into 3 groups according to different surgical fixation methods: group ESIN-A of 36 cases, group KW-R of 52 cases, and group ESIN-RPS of 24 cases. The operation time, intraoperative bleeding, fluoroscopy times, alignment rates and residual angulations by the anteroposterior and lateral X-ray films immediately after reduction were compared among the 3 groups. The Gartland-Werley evaluation of wrist function and complications were compared at the last follow-up.Results:There was no statistically significant difference in the preoperative general data among the 3 groups, indicating comparability ( P>0.05). In the operation time, group KW-R [(71.2±9.2) min] > group ESIN-A [(65.1±13.1) min] > group ESIN-RPS [(51.7±17.1) min]; in the fluoroscopy times, group KW-R [(13.9±6.3) times] > group ESIN-A [(9.0±2.8) times] > group ESIN-RPS [(6.4±2.0) times]; in the alignment rates by the anteroposterior and lateral X-ray films immediately after reduction, group ESIN-RPS (93.1%±4.6% and 95.2%±3.3%) > group KW-R (82.1%±11.0% and 88.1%±7.4%) > group ESIN-A (80.4%±9.9% and 86.7%±6.9%); in the residual angulations by the anteroposterior and lateral X-ray films immediately after reduction, group ESIN-RPS (3.3°±1.8° and 2.9°±2.1°) < group ESIN-A (5.2°±1.0° and 5.0°±3.2°) < group KW-R (6.6°±1.6°and 7.5°±2.7°). Pairwise comparisons in the above items were statistically significant ( P<0.05). In group ESIN-A, the incision length [(1.8±0.3) cm] was significantlylonger than that in group ESIN-RPS [(1.4±0.2) cm], and the intraoperative blood loss [(8.3±2.2) mL] significantly larger than that in group ESIN-RPS [(5.5±1.6) mL] ( P<0.05). One year after operation, the excellent and good rate by the Gartland-Werley evaluation of wrist function in groups ESIN-RPS, ESIN-A and KW-R, respectively, were 95.8% (23/24), 86.5% (31/36) and 86.1% (46/52), showing no statistically significant difference between the 3 group ( P>0.05), and the major incidence of complications in group KW-R (25.0%, 13/52) and in group ESIN-A (25.0%, 9/36) were significantly higher than that in group ESIN-RPS (4.2%, 1/24) ( P<0.05). Conclusion:In the treatment of DRMDJ fractures in children, compared with ESIN-A and KW-R, ESIN-RPS is an effective choice due to its advantages of shorter operation time, less intraoperative blood loss, less radiation, better alignment, and fewer complications.

2.
Chinese Journal of Orthopaedics ; (12): 1084-1092, 2022.
Artigo em Chinês | WPRIM | ID: wpr-957102

RESUMO

Methods:Two thousand standard sections images werre collected from 2 000 clinical retrospective pediatric hip ultrasound videos from January 2019 to January 2021. All standard sections were annotated by the annotation team through the self-designed software based on Python 3.6 environment for image cross-media data annotation and manual review standardization process with unified standards. Among them, 1 753 were randomly selected for training the deep learning system, and the remaining 247 were used for testing the system. Further, 200 standard sections were randomly selected from the test set, and 8 clinicians independently completed the film reading annotation. The 8 independent results were then compared with the AI results.Results:The testing set consists of 247 patients. Compared with the clinician's measurements, the area under the receiver operating characteristic curve (AUC) of diagnosing hip joint maturity was 0.865, the sensitivity was 76.19%, and the specificity was 96.9%. The AUC of AI system interpretation under Graf detailed typing was 0.575, the sensitivity was 25.90%, the specificity was 89.10%. The 95% LoA of α-angle determined by Bland-Altman method, of -4.7051° to 6.5948° ( Bias -0.94, P<0.001), compared with clinicians' measurements. The 95% LoA of β-angle, of -7.7191 to 6.8777 ( Bias -0.42, P=0.077). Compared with those from 8 clinicians, the results of AI system interpretation were more stable, and the β-angle effect was more prominent. Conclusion:The AI system can quickly and accurately measure the Graf correlation index of standard DDH ultrasonic standard diagnosis plane.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA