Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of China Pharmaceutical University ; (6): 553-557, 2018.
Artigo em Chinês | WPRIM | ID: wpr-811756

RESUMO

@#By using(S)-MonoPHOS and [Rh(COD)2]BF4 as catalyst, the asymmetric hydrogenation reactions of methyl-2-acylamino-3-arylacrylate and the effect of different amino protective groups on hydrogenation efficacy were studied. The products resulting from asymmetric hydrogenation were hydrolyzed by hydrochloric acid, and the corresponding amino acids were obtained at yields of 63%- 92%.

2.
Chinese Medical Equipment Journal ; (6): 80-82,93, 2017.
Artigo em Chinês | WPRIM | ID: wpr-606515

RESUMO

Objective To compare the effects of two head holders on the setup errors during head and neck neoplasms radiotherapy.Methods Totally 30 patients were divided into groups A and B randomly and equally.Group A applied TypeSTM Extension for setup,and group B used Type-S Overlay Board,with thermoplastic film applied to fixation.Varian23IX image guided linear accelerator was involved in the therapy,and the patients underwent CBCT-guided therapy once a week in 6 weeks.The setup errors at left-right,head-foot and anterior-posterior directions were obtained by bone registration and manual checking.Results The absolute setup error at anterior-posterior direction of group A,was (2.31 ± 1.35) mm,which was significantly higher than (1.88±1.79) mm of group B (P=0.032).There were no obvious differences between the setup errors of group A and those of group B (P>0.05),and the weekly absolute errors of group A were not statistically different from those of group B (P>0.05).Conclusion There are no significant differences between the effects of the two head holders on the setup errors during head and neck neoplasms radiotherapy,and proper head holder can be selected according to clinical requirements.

3.
Journal of China Pharmaceutical University ; (6): 178-180, 2015.
Artigo em Chinês | WPRIM | ID: wpr-811930

RESUMO

@#In the investigation of asymmetric catalytic hydrogenation reaction, (Z)-methyl-2-acetamidocinnamate is often used as a standard substrate to assess the chiral catalysts. However, its previous syntheses suffered from low yield, relying on column chromatography for isolation. Herein, (Z)-methyl-2-acetamidocinnamate was obtained with 68. 5% isolation yield via simple operations such as wash and extraction using dicyclohexylcarbodiimide(DCC)as dehydrant and 4-dimethylaminopyridine(DMAP)as catalyst in the last synthetic step.

4.
Chinese Journal of Medical Instrumentation ; (6): 299-301, 2015.
Artigo em Chinês | WPRIM | ID: wpr-265637

RESUMO

<p><b>OBJECTIVE</b>To discuss the influence of setup errors on the accuracy of pelvic cancer in IGRT, analysis setup errors and determine the CTV-to-PTV margins.</p><p><b>METHODS</b>60 pelvic cancer patients treated with Varian 23IX, all of them were performed by CBCT before and after-correction three times in the first week and after that once a week. Then, to measure the setup errors at X(left-right), Y(superior-inferior), Z(anterior-posterior) axis and E(coronal), F(sagittal), G(axial) rotation directions.</p><p><b>RESULTS</b>530 scans obtained in all, the setup errors in X, Y, Z, E, F, G were (-0.52 ± 4.18) mm, (0.73 ± 4.86) mm, (-0.36 ± 3.62) mm, (0.14 ± 1.20)degrees, (0.13 ± 1.34)degrees, (0.21 ± 1.73)degrees respectively and were much lower after correction at X, Y, Z axis, besides, CTV-to-PTV margins decrease a lot.</p><p><b>CONCLUSION</b>The accuracy of radiotherapy can be highly increased with the use of IGRT in pelvic cancer.</p>


Assuntos
Humanos , Neoplasias Pélvicas , Radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem
5.
Chinese Journal of Cellular and Molecular Immunology ; (12): 980-983, 2009.
Artigo em Chinês | WPRIM | ID: wpr-622311

RESUMO

AIM: To prepare Nano-Liposome encapsulated MAGE3/HSP70(NL M3H) and study its character and antitumor immunity in mouse. METHODS: NL M3H was prepared by the thin film-dispersion ultrasonic. The shape and size of NL M3H were detected by electron microscope. The encapsulation rate, drug-carrying capacity, stability and the releasing character were tested by Sephedex-G100 gel filtration. The mouse was immunized by NL M3H, and the antitumor immunity was detected by ELISPOT and LDH release assay. RESULTS: The mean size of NL M3H was lower than 100 nm. The encapsulation rate was 38%.The drug content was 0.038 g/L. NL M3H has good stability after stored in 4℃ for 6 months. The releasing profile showed that 74 percent of proteins was released during the first 24 hours in saline. The results of ELISPOT and LDH release assay showed that NL M3H generated tumor specific cytotoxic T lymphocyte(CTL)to damage tumor cel1. CONCLUSION: NL M3H has novel characters, it can generate specific CTL to kill tumor cell, and can be used as new kind of vaccine agsinst tumor.

6.
Chinese Journal of Radiation Oncology ; (6): 106-108, 2008.
Artigo em Chinês | WPRIM | ID: wpr-402030

RESUMO

Objective To study the effect of various methods determining lung volume and fraction dose on the lung dose-volume parameters for lung cancer patients. Methods Twenty patients with lung cancer were rantdomly enrolled into our study and the plan of three dimensional eonformal radiation therapy(3DCRT)was designed by Varian Eclipse TPS.The lung volumes and the dose-volume parameters were measured under CT value of-300- -980, -400- -980 and -500- -980.Under CT value of -400- -980,total lung volumes were confirmed.The dose-volume parameters of V30,V20,V10 and mean lung dose(MLD)were reevaluated after GTV,CTV and PTV were subtracted from the total lung volumes and when the fraction dose was elevated from 2.0 Gy to 10.0 Gy. Results When the CT value ranged from-300--980 to-500--980,the median reduction of the total lung volumes(-9.10%)was significantly higher than that of V30,V20,V10 and MLD(-3.18%,-1.13%,0.82%and-0.79%,respectively).When the total lung volume was fixed at CT value of-400--980,the alterations of V30,V20,V10 and MLD became more apparent as the increase of the subtracted lung volume,among which the alteration of V30 was most significant while V10 the least.Among five cases with a fixed total dose of 60 Gy and PTV less than 140 cm3,the V30,V20,V10 and MLD were increased to a similar extent(about 40%)when the fraction dose was increased from 2.0 Gy to 10.0 Gy.MLD was increased(36%)when the fraction dose was above 6.0 Gy. Conclusions When CT value ranges from-300- -980 to-500- -980,the total lung volume is influenced most.The alteration of V30,being statistically significant,might have some significance but is not enough to determine the plan of radiotherapy clinically.The alteration of V20、V10 and MLD is not statistically significant.When the overlapped target volume is subtracted from the total lung volumes,the alteration of V30 is the most sign:tifhcant while V10 the least.The fraction dose,being the most consuming factor(>10%)when comparing with the CT valHe and targeted volume,can significantly influence the dose-volume parameter.

7.
Chinese Medical Equipment Journal ; (6)2004.
Artigo em Chinês | WPRIM | ID: wpr-595497

RESUMO

Objective To compare the results of CT/MRI registration by using two different marker materials. Methods CT and MR transversal images (using electric wire and thin tube filled with lohexol injection as matching points respectively) were obtained from nine cases with brain tumor. Another CT and MR transversal images were also obtained by using the cod-liver oil capsule filled with gadopentetate dimeglumine injection as matching points with the same scanning position. The images were transferred to the TPS for image registration and the effect was evaluated. Results The CT/MRI CRE range for using different kinds of marker material was 0.16-0.28cm,while was 0.06-0.16cm for using the same marker material. Conclusion Comparing with the method using different kinds of material,the method using the same spherical material can get better results in CT/MRI registration.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA