Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Progress in Modern Biomedicine ; (24): 4471-4474, 2017.
Artigo em Chinês | WPRIM | ID: wpr-615064

RESUMO

Objective:To investigate the safety and efficacy of ultrasound-guided transvaginal radiofrequency ablation in the treat ment of symptomatic uterine fibroid.Methods:39 patients with symptomatic uterine fibroid underwent transvaginal radiofrequency ablation therapy were selected Before treatment,the fibroid size and volume were measured using ultrasound.The fibroid-related symptom severity and quality of life were scored using uterine fibroid symptom and quality of life survey.The fibroid volume reduction rate,improvement in clinical symptom and quality of life,and ovarian function of patients were observed before treatment and at three,six,nine and 12 months after treatment.Results:The average operation time of radiofrequency ablation was 25 minutes.There was no clear intraand postoperative complication.Preoperative fibroid volume was 65.2± 49.3cm3,which was reduced to 32.2± 27.6 cm3,21.2± 18.2 cm3,15.3± 12.1 cm3 and 10.3± 9.8 cm3 at 3,6,9 and 12 months after treatment,respectively(P<0.05).The symptom severity score (SSS) was 60.23± 13.2 before treatment,and gradually decreased to 42.2± 11.4,21.1± 10.2,15.4± 10.3 and 12.2± 9.7 at 3,6,9 and 12 months after treatment(P<0.05).The quality of life (QOL) score gradually increased from 58.24± 16.24 before treatment to 70.3± 20.3,81.4± 8.6,86.3± 7.6 and 88.2± 9.1 at 3,6,9 and 12 months after treatment (P<0.05).The levels of follicle stimulating hormone,luteinizing hormone and estradiol at 3,6,9 and 12 months after treatment showed no difference compared with these before treatment (P>0.05).Conclusions:Ultrasound-guided transvaginal radiofrequency therapy was a minimally invasive,safe,and effective therapy for symptomatic uterine fibroid.

2.
Progress in Modern Biomedicine ; (24): 4967-4970,4966, 2017.
Artigo em Chinês | WPRIM | ID: wpr-614917

RESUMO

Objective:To investigate the application value of real-time ultrasound elastography in the treatment of fibroids radiofrequency ablation (RFA).Methods:Transvaginal ultrasonography,Real-time ultrasound elastography (RTE) and contrast-enhanced ultrasonography (CEUS) were performed on 34 patients with a total of 38 uterine fibroids who had the treatment of RFA before,1 hour and 3 months after the treatment of RFA.Detected the diameters of the lesions with the three methods of CEUS,RTE and 2D.Analysed the elastic image features and divided into groups,Measured the elastic strain ratio and compared the E/E0 in and between the group.The difference of lesion diameter between 2D,RTE and CEUS was compared.When the image of lesions showed blue and green was taken as the cirterion of incomplete ablation after RFA,conpared with CEUS,analysed the consistency of RTE and CEUS in evaluating the degree of ablation.Results:The lesions were divided into 3 groups according to the preoperative elastic image,with 8 (21.1%) in the blue group,20 (52.6%) in blue-based and 10 (26.3%) in green-based group.The difference was obvious in E/E0 between the 3 groups before RFA.There was no significant difference in E/E0 between 1 hour and 3 months after RFA (P > 0.05).In each group the E/E0 of lesions were significantly increased at 1 hour and 3 months after the treatment of FRA,and the hardness of 3 months after RFA was harder than that of 1 hour after RFA(P<0.05).The diameter measured by RTE was larger than that by 2D and CEUS before RFA(P>0.05).The diameter measured by 2D was larger than that by RTE and CEUS at 1 hour after RFA (P<0.05).No statistically significant difference was found in the lesion diameters among the three methods of2D,RTE and CEUS at 3 months after the treatment ofRFA (P>0.05).CEUS and RTE had the basic consistent in the evaluation of lesions ablation degree at 1 hour (kappa=0.46) and 3 months (kappa=0.54) after the treatment of RFA.Conclusions:After RFA,the myoma gradually hardens,and RTE can reflect the change of the hardness,RTE can clearly show the boundary of uterine ftbroids especially after the treatment of RFA,can be used in the prediction of lesions ablation degree,so there was a certain application value of RTE used in RFA.

3.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 45-50, 2017.
Artigo em Chinês | WPRIM | ID: wpr-711982

RESUMO

Objective To investigate the value of real-time elastography (RTE) in evaluating the characteristics and elasticity index (E-index) changes at different echo level of uterine fibroids before and after radiofrequency ablation (RFA).Methods A total of 43 patients (with 55 lesions) accepted RFA under ultrasound guidance in the Fourth Affiliated Hospital of Harbin Medical University from September 2013 to January 2015.All lesions were confirmed to have no perfusion through ultrasonography 1 h after RFA.The diameter of lesions ranging from 1.0 cm to 3.0 cm (with an average of 1.9± 1.2 cm).Preoperative lesions were classified into 3 groups for comparison based on ultrasonic echo type,group A:hypo echo (n=30);group B:hyper echo (n=12);and group C:mixed echo (n=12).Measured elasticity index E-index and internal uniformity (△ E) were analyzed.Comparisons of E value and△ E value were performed with repeated measures.RTE images features using x2 test of Fisher inspection comparison at the same time differences between groups.Results (1) Before RFA,RTE images showed blue alternating with green with green being dominated accounting for 70% (21/30).50% of RTE images in group B were completely covered in blue (6/12),while group C exhibited 53.9% blue alternating with green with blue being dominated (7/13).There were statistically significant characteristics of RTE images among 3 groups (P < 0.01).1 h after RFA,74.5% lesions exhibited with blue being dominated (41/55).However,83.6% (41/55) exhibited with blue 3 months after RFA.The difference in characteristics of RTE among 3 groups displayed no statistical significance (P > 0.05).(2) The comparison of E-index revealed that before RFA,the E value was the lowest in the group A and the highest in the group B,while the group C was between them.There was significant difference between group A and B (F=19.25,P < 0.01).E-index elevated in all the three groups and significant differences were found 1 h,3 month after RFA in comparison with that before RFA in the group A (F=386.75,294.68,both P < 0.01).In addition,significant differences were also found 1 h,3 month after RFA in comparison with the treatment in the group B (F=29.98,45.88,both P < 0.01).As for the group C,there were significant differences in E-index 1 h,3 month after RFA compared with before RFA (F=120.29,139.64,both P < 0.01).3 months after RFA,E-index further elevated in the three groups and no significant inter-group difference was found at the same time points (P > 0.05).(3)Before RFA,the△ E value was lower in group A and group B,while higher in the group C,group C presenting significant difference from group A and B (F=484.68,344.15,both P < 0.01).At 1 h after RFA,△ E value was higher in group A and group C,while lower in group B,with group B showing significant difference from the low and mixed echo groups (F=53.58,94.79,both P < 0.01).Significant difference was observed 1 h after surgery compared to before RFA in group A (F=154.35,P < 0.01).Significant difference was also found 1 h after RFA compared to 3 month after RFA in group A (F=266.85,P < 0.01).As for group C,there were also significant differences in△ E-index before treatment and 1 h after RFA compared with 3 month after RFA (F=103.24,76.53,both P < 0.01).At 3 months after RFA,△ E-index decreased in all three groups.No significant inter-group difference was found at the same time points (all P > 0.05).Conclusions RTE characteristics and the elasticity index are distinctly different among uterine fibroid at various echo intensities.RTE contributes to judging changes in hardness before and after RFA.The application of RTE for quantitative comparison of lesion hardness and uniformity can be served as the foundation for evaluating therapeutic effects of RFA.

4.
Chinese Journal of Behavioral Medicine and Brain Science ; (12): 883-885, 2013.
Artigo em Chinês | WPRIM | ID: wpr-441922

RESUMO

Objective To explore the effects of mangiterin on behaviors and brain-derived neurotrophic factor(BDNF) of hippocampus in chronic stress depression mice.Methods 60 male mice were randomly divided into normol control group,model group,fluoxetin control group and mangiterin groups (low,medium and high dose),10 mice in each group.All mice except normal control group were singly housed and subjected to chronic stress-induced depression model for 21 consecutive days.The behaviors of mice were detected by open-field test and tail-suspension test.The expression of BDNF in the hippocampus were assessed using western blot.Results Compared with the normal group,mice exposed chronic stress showed decreased body weight((5.33 ±1.20) g),crossing lines (102 ± 18) and distances ((3425 ± 112) mm) notably decreased in open-field behavior test.The duration of immobility during tail-suspension was increased significantly.BDNF expression in the hippocampus(0.45 ± 0.03) was downregulated significantly(P< 0.01),while it was upregulated in the groups of mangiterin(P < 0.01).Mangiterin group in high dose had the similar effects to fluoxetin group(P > 0.05).Conclusion Mangiterin can ameliorate behavior impairment of chronic stress induced-depression mice and it may be related to the upregulation of BDNF expression in the hippocampus.

5.
Chinese Journal of Medical Education Research ; (12)2006.
Artigo em Chinês | WPRIM | ID: wpr-624475

RESUMO

In order to enhance the students’knowledge of clinical medicine and lay the foundation for using clinical medicine,we adjusted the content and compiled pharmacognosy teaching materials,aiming at its professional features of clinical pharmacy of Xuzhou Medical College.The pharmacognosy teaching material has been applied in several rounds.Feedback from students suggested that using this teaching material was well-targeted,clear and practical.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA