Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Neuroscience Bulletin ; (6): 815-830, 2021.
Artigo em Chinês | WPRIM | ID: wpr-951983

RESUMO

Key requirements of successful animal behavior research in the laboratory are robustness, objectivity, and high throughput, which apply to both the recording and analysis of behavior. Many automatic methods of monitoring animal behavior meet these requirements. However, they usually depend on high-performing hardware and sophisticated software, which may be expensive. Here, we describe an automatic infrared behavior-monitor (AIBM) system based on an infrared touchscreen frame. Using this, animal positions can be recorded and used for further behavioral analysis by any PC supporting touch events. This system detects animal behavior in real time and gives closed-loop feedback using relatively low computing resources and simple algorithms. The AIBM system automatically records and analyzes multiple types of animal behavior in a highly efficient, unbiased, and low-cost manner.

2.
Chinese Journal of Medical Imaging ; (12): 105-108, 2017.
Artigo em Chinês | WPRIM | ID: wpr-505831

RESUMO

Purpose To explore the feasibility of low radiation dose combined with lowdose contrast agent in thyroid CT enhanced scan and investigate the benefit of reducing radiation hazard and contrast agent damage to thyroid.Materials and Methods 120 patients assigned for thyroid enhanced CT scan were prospectively and randomly divided into four groups (each group was 30 patients).Group A:radiation dose 120 kV,180 mA,contrast agent dose 1.2 ml/kg;group B:radiation dose 120 kV,180 mA,contrast agent dose 1.0 ml/kg;group C:radiation dose 100 kV,100 mA,contrast agent dose 1.2 ml/kg;group D:radiation dose 100 kV,100 mA,contrast agent dose 1.0 ml/kg.CT values,background sign,background noise of thyroid were measured;signal to noise ratio (SNR) and contrast to noise ratio (CNR) were calculated;CT dose index of volume (CTDIvol),dose length product (DLP),and the effective dose (ED) were recorded and calculated.The image quality was evaluated and the data was statistically analyzed by two radiologists.Results CT values,background sign and background noise of thyroid,as well as CTDIvol,DLP,ED among four groups were statistical significant (P<0.05);there was no significant difference in SNR,CNR and image quality scores among four groups (P>0.05).Conclusion It is beneficial of reducing radiation hazard and side-effect of contrast agent from low radiation dose combined with low-dose contrast agent under the condition of ensuring diagnostic image quality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA