Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Journal of the Korean Shoulder and Elbow Society ; : 143-148, 2016.
Artigo em Inglês | WPRIM | ID: wpr-770763

RESUMO

BACKGROUND: The purpose of our study was to evaluate the accuracy of reduction based on postoperative computed tomography (CT) images after arthroscopic stabilization using tightrope system for unstable distal clavicle fracture. METHODS: Twelve patients with distal clavicle fracture combined with coracoclavicular (CC) ligament injury (type II, V) who received arthroscopically assisted fixation using a flip button device were evaluated for accuracy of reduction using 3-dimensional postoperative CT scan by measuring the degree of distal clavicular angulation and clavicular shortening. RESULTS: Immediate postoperative plain radiograph confirmed restoration of the CC distance (CCD) in 10 patients. At final follow-up, the CCD remained reduced anatomically on plain radiographs in these patients. All patients showed excessive posterior angulation and shortening compared to the opposite side. The average Constant score recovered to 94.8 at final follow-up. CONCLUSIONS: Indirect reduction and arthroscopic subacromial approach with flip button fixation of unstable distal clavicle fractures demonstrated favorable clinical results despite unavoidable posterior angulation of distal clavicle and shortening the total length of clavicle.


Assuntos
Humanos , Artroscopia , Clavícula , Seguimentos , Ligamentos , Tomografia Computadorizada por Raios X
2.
Clinics in Shoulder and Elbow ; : 143-148, 2016.
Artigo em Inglês | WPRIM | ID: wpr-216522

RESUMO

BACKGROUND: The purpose of our study was to evaluate the accuracy of reduction based on postoperative computed tomography (CT) images after arthroscopic stabilization using tightrope system for unstable distal clavicle fracture. METHODS: Twelve patients with distal clavicle fracture combined with coracoclavicular (CC) ligament injury (type II, V) who received arthroscopically assisted fixation using a flip button device were evaluated for accuracy of reduction using 3-dimensional postoperative CT scan by measuring the degree of distal clavicular angulation and clavicular shortening. RESULTS: Immediate postoperative plain radiograph confirmed restoration of the CC distance (CCD) in 10 patients. At final follow-up, the CCD remained reduced anatomically on plain radiographs in these patients. All patients showed excessive posterior angulation and shortening compared to the opposite side. The average Constant score recovered to 94.8 at final follow-up. CONCLUSIONS: Indirect reduction and arthroscopic subacromial approach with flip button fixation of unstable distal clavicle fractures demonstrated favorable clinical results despite unavoidable posterior angulation of distal clavicle and shortening the total length of clavicle.


Assuntos
Humanos , Artroscopia , Clavícula , Seguimentos , Ligamentos , Tomografia Computadorizada por Raios X
3.
Yonsei Medical Journal ; : 1199-1208, 2016.
Artigo em Inglês | WPRIM | ID: wpr-79773

RESUMO

PURPOSE: The purpose of this study was to compare the clinical outcomes of arthroscopic anatomical double bundle (DB) anterior cruciate ligament (ACL) reconstruction with either selective anteromedial (AM) or posterolateral (PL) bundle reconstruction while preserving a relatively healthy ACL bundle. MATERIALS AND METHODS: The authors evaluated 98 patients with a mean follow-up of 30.8±4.0 months who had undergone DB or selective bundle ACL reconstructions. Of these, 34 cases underwent DB ACL reconstruction (group A), 34 underwent selective AM bundle reconstruction (group B), and 30 underwent selective PL bundle reconstructions (group C). These groups were compared with respect to Lysholm and International Knee Documentation Committee (IKDC) score, side-to-side differences of anterior laxity measured by KT-2000 arthrometer at 30 lbs, and stress radiography and Lachman and pivot shift test results. Pre- and post-operative data were objectively evaluated using a statistical approach. RESULTS: The preoperative anterior instability measured by manual stress radiography at 90° of knee flexion in group A was significantly greater than that in groups B and C (all p<0.001). At last follow-up, mean side-to-side instrumented laxities measured by the KT-2000 and manual stress radiography were significantly improved from preoperative data in all groups (all p<0.001). There were no significant differences between the three groups in anterior instability measured by KT-2000 arthrometer, pivot shift, or functional scores. CONCLUSION: Selective bundle reconstruction in partial ACL tears offers comparable clinical results to DB reconstruction in complete ACL tears.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Artroscopia , Tratamentos com Preservação do Órgão/métodos , Resultado do Tratamento
4.
Journal of Korean Society of Spine Surgery ; : 192-196, 2015.
Artigo em Coreano | WPRIM | ID: wpr-118120

RESUMO

STUDY DESIGN: Review of the literature. OBJECTIVES: To present updated information on percutaneous vertebral augmentation (PVA) for osteoporotic spinal fractures (OSFs). SUMMARY OF LITERATURE REVIEW: Vertebroplasty and kyphoplasty have been used to treat osteoporotic spinal fractures for many years. A recent meta-analysis provides strong evidence in favor of cement augmentation in the treatment of symptomatic vertebral compression fractures. MATERIALS AND METHODS: Review of the relevant literature. RESULTS: A meta-analysis showed greater pain relief, functional recovery, and improvement in quality of life with cement augmentation compared with control subjects. CONCLUSIONS: Percutaneous vertebral augmentation of osteoporotic spinal fractures results in shorter hospital stays, reduced incidence of complications, and more rapid return of functional independence.


Assuntos
Fraturas por Compressão , Incidência , Cifoplastia , Tempo de Internação , Qualidade de Vida , Fraturas da Coluna Vertebral , Vertebroplastia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA