Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Korean Medical Science ; : 1676-1679, 2010.
Artigo em Inglês | WPRIM | ID: wpr-152646

RESUMO

Anti-erythropoietin antibodies usually cross-react with all kinds of recombinant erythropoietins; therefore, erythropoiesis-stimulating agent (ESA)-induced pure red-cell aplasia (PRCA) is not rescued by different ESAs. Here, we present a case of ESA-induced PRCA in a 36-yr-old woman with chronic kidney disease, whose anemic condition improved following reintroduction of darbepoetin-alpha. The patient developed progressive, severe anemia after the use of erythropoietin-alpha. As the anemia did not improve after the administration of either other erythropoietin-alpha products or erythropoietin-beta, all ESAs were discontinued. Oxymetholone therapy failed to improve the transfusion-dependent anemia and a rechallenge with ESAs continuously failed to obtain a sustained response. However, her anemia improved following reintroduction of darbepoetin-alpha at 3 yr after the initial diagnosis. Interestingly, anti-erythropoietin antibodies were still detectable, although their concentration was too low for titration. In conclusion, darbepoetin-alpha can improve ESA-induced PRCA when the anti-erythropoietin antibody titer declines and its neutralizing capacity is lost.


Assuntos
Adulto , Feminino , Humanos , Anemia/tratamento farmacológico , Anticorpos/sangue , Células da Medula Óssea/patologia , Hipersensibilidade a Drogas/imunologia , Eritropoetina/análogos & derivados , Eritropoetina/efeitos adversos , Glomerulonefrite por IGA/complicações , Hematínicos/efeitos adversos , Falência Renal Crônica/complicações , Oximetolona/uso terapêutico , Aplasia Pura de Série Vermelha/induzido quimicamente
2.
Korean Circulation Journal ; : 1017-1023, 1992.
Artigo em Coreano | WPRIM | ID: wpr-203427

RESUMO

BACKGROUND: There is pressure difference depending on the height of hand position when blood pressure is taken, applying the oscillometric electronic digital BP(blood pressure) monitor. Authors have calculated the degree of BP differences, and evaluated the accuracy and effectiveness of the digital BP monitor comparing with the conventional Mercury Sphygmomanometer. METHOD: Randomized sixty cases consisting of in-patients and hospital workers were subjected for this study. BPs were taken at three different levels-nose level, heart level and knee level-on conventional sitting position applying OMRON Digital Automatic Blood Pressure Monitor and conventional Mercury Sphygmomanometer, and statistical analysis was made. RESULTS: At the nose level, systolic BP and diastolic BP were lower with 23.5mmHg and 18.9mmHg respectively, than at the heart level, while at the knee level, they were higher with 21mmHg and 17.5mmHg respectively, than at the heart level. No actual statistical difference of systolic and diastolic values between OMRON Digital Automatic Blood Pressure Monitoring method at the heart level and conventional Mercury Sphygmomanometeric method. CONCLUSION: Present study demonstrated significant discrepancy of BP values, in systolic and diastolic values, depending on the height of measured finger, when OMRON Digital Automatic Blood Pressure Monitor is applied in taking BP on conventional sitting position. However, no actual discrepancy of BP values was noted between two methods when BP is taken at heart level by OMRON Digital Automatic Blood Pressure Monitor and on brachial artery BP by conventional Mercury Sphygmomanometer. Thus OMRON Digital Automatic Blood Pressure Monitor could take the place of Mercury Sphygmomanometer in taking peripheral BP, which subsequently enable us to estimate central artery BP, which is believed to be better clinical index, through this much more handy electrical oscillometric device in the future.


Assuntos
Artérias , Pressão Sanguínea , Monitores de Pressão Arterial , Artéria Braquial , Impedância Elétrica , Dedos , Mãos , Coração , Pressão Hidrostática , Joelho , Nariz , Esfigmomanômetros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA