Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
The Journal of Advanced Prosthodontics ; : 202-213, 2023.
Artigo em Inglês | WPRIM | ID: wpr-1002869

RESUMO

PURPOSE@#This prospective clinical study was conducted to evaluate the clinical usefulness of the freely detachable zirconia ball- and spring-retained implant prosthesis (BSRP) through a comparative analysis of screw- and cement-retained implant prosthesis (SCRP). @*MATERIALS AND METHODS@#A multi-center, randomized, prospective clinical study evaluating the clinical usefulness of the detachable zirconia ball- and spring-retained implant prostheses was conducted. Sixty-four implant prostheses in 64 patients were examined. Periodic observational studies were conducted at 0, 3, 6, and 12 months after delivery of the implant prosthesis. Factors such as implant success rate, marginal bone resorption, periodontal pocket depth, plaque and bleeding index, and prosthetic complications were evaluated, respectively. @*RESULTS@#During the 1-year observation period, all implants survived without functional problems and clinical mobility, showing a 100% implant success rate. Marginal bone resorption was significantly higher in the SCRP group than in the BSRP group only at the time of implant prosthesis delivery (P = .043). In all observation periods, periodontal pocket depth was slightly higher in the BSRP group than in the SCRP group, but there was no significant difference (P > .05). The modified plaque index (mPI) scores of both groups were moderate. Higher ratio of a score 2 in modified sulcus bleeding index (mBI) was observed in the BSRP group in the 6- and 12-months observation. @*CONCLUSION@#Within the limitations of this study, the newly developed zirconia ball- and spring-retained implant prosthesis could be considered as an applicable and predictable treatment method along with the existing screw- and cement-retained prosthesis.

2.
Journal of Korean Dental Science ; : 61-67, 2022.
Artigo em Inglês | WPRIM | ID: wpr-938005

RESUMO

Purpose@#This study aimed to evaluate the accuracy of bite registration using intraoral scanner based on data trimming strategy for fremitus teeth. @*Materials and Methods@#A reference model was designed by Medit Model Builder software (MEDIT Corp., Seoul). Tooth number 24 and 25 were separated as dies and tooth number 26 was prepared for full-coverage crown. Those were printed using a 3D printer (NextDent 5100). The scanning procedure was performed by a single trained operator with one intraoral scanner (i700; MEDIT Corp.). The scanning groups were divided as follows: group 1 (G1), no fremitus; group 2 (G2), 0.5 mm buccal fremitus in the maxillary left first and second premolar; and group 3 (G3), 1.5 mm buccal fremitus in the maxillary left first and second premolar. Each group was scanned 10 times and were analyzed using the reference model data. Surface-based occlusal clearance was analyzed at the prepared tooth to evaluate accuracy.Result: Mean values of control group (G1) were 1.587±0.021 mm. G2 showed similar values to those from the control group (1.580±0.024 mm before trimming strategy and 1.588±0.052 mm after trimming strategy). G3 showed significantly greater values (1.627±0.025 mm before trimming strategy and 1.590±0.024 mm after trimming strategy) and the differences were found between trimming strategy (P=0.004). @*Conclusion@#Bite trimming strategy for fremitus teeth is a reliable technique to reduce inaccuracies caused by the mobility at maximum intercuspation.

3.
Journal of Korean Dental Science ; : 9-18, 2022.
Artigo em Inglês | WPRIM | ID: wpr-938001

RESUMO

Purpose@#The purpose of this study was to evaluate whether three-dimensional (3D)-printed flexible denture resin has suitable mechanical properties for use as a thermoplastic denture base resin material. @*Materials and Methods@#A total of 96 specimens were prepared using the 3D printed flexible denture resin (Flexible Denture). Specimens were designed in CAD software (Tinkercad) and printed through a digital light-processing 3D printer (Asiga MAX UV). Post-polymerization process was conducted according to air exposure or glycerin immersion at 35°C or 60°C and for 30 or 60 minutes. The maximum flexural strength, elastic modulus, 0.2% offset yield strength, and Vickers hardness of 3D-printed flexible denture resin were assessed.Result: The maximum flexural strength ranged from 64.46±2.03 to 84.25±4.32 MPa, the 0.2% offset yield strength ranged from 35.28±1.05 to 46.13±2.33 MPa, the elastic modulus ranged from 1,764.70±64.66 to 2,179.16±140.01 MPa, and the Vickers hardness ranged from 7.01±0.40 to 11.45±0.69 kg/mm2 . @*Conclusion@#Within the limits of the present study, the maximum flexural strength, 0.2% offset yield strength, elastic modulus, and Vickers hardness are sufficient for clinical use under the post-polymerization conditions of 60°C at 60 minutes with or without glycerin precipitation.

4.
Journal of Korean Dental Science ; : 43-51, 2020.
Artigo em Inglês | WPRIM | ID: wpr-899656

RESUMO

Purpose@#The practical examination portion of the National Dental Licensing Examination (NDLE) is slated to be administered in the latter half of 2021 in the form of a clinical performance examination that comprehensively evaluates the patient-dentist interaction using standardized patients (SPs). The SPs should be equipped with the basic qualities and capacity as evaluators for a fair and reliable administration of the test. @*Materials and Methods@#In this study, we analyzed the existing training materials for SPs who participated in domestic and overseas practical tests for the development of training materials for SPs through seminars and surveys of 11 dentistry schools and colleges.Result: First, SPs should be selected according to the basic quality criteria and capacity, which they must possess, and the preliminary basic training about the details which they must have knowledge of and be provided through videorecorded cases before the implementation of the preliminary field training. Second, the roles of SPs and the calibration process of the evaluation result forms are needed when conducting the preliminary field training for SPs. After watching video-recorded scenario cases, the SPs participate in discussions about the watched videos before proceeding to calibration practices of evaluation result forms. Third, because the Type A questionnaire of the practical examination of the NDLE is dependent on the SPs’ capacity and training, the fairness of the practical test is largely dependent on the SPs. Therefore, practicing the roles as evaluators and evaluation training should be provided using practical test items that can improve the reliability of the test and show a high level of reproducibility about the same case. @*Conclusion@#The findings of this study will be utilized for the development of training materials for SPs, so they can participate in the administration of a fair and reliable practical examination of the NDLE.

5.
Journal of Korean Dental Science ; : 43-51, 2020.
Artigo em Inglês | WPRIM | ID: wpr-891952

RESUMO

Purpose@#The practical examination portion of the National Dental Licensing Examination (NDLE) is slated to be administered in the latter half of 2021 in the form of a clinical performance examination that comprehensively evaluates the patient-dentist interaction using standardized patients (SPs). The SPs should be equipped with the basic qualities and capacity as evaluators for a fair and reliable administration of the test. @*Materials and Methods@#In this study, we analyzed the existing training materials for SPs who participated in domestic and overseas practical tests for the development of training materials for SPs through seminars and surveys of 11 dentistry schools and colleges.Result: First, SPs should be selected according to the basic quality criteria and capacity, which they must possess, and the preliminary basic training about the details which they must have knowledge of and be provided through videorecorded cases before the implementation of the preliminary field training. Second, the roles of SPs and the calibration process of the evaluation result forms are needed when conducting the preliminary field training for SPs. After watching video-recorded scenario cases, the SPs participate in discussions about the watched videos before proceeding to calibration practices of evaluation result forms. Third, because the Type A questionnaire of the practical examination of the NDLE is dependent on the SPs’ capacity and training, the fairness of the practical test is largely dependent on the SPs. Therefore, practicing the roles as evaluators and evaluation training should be provided using practical test items that can improve the reliability of the test and show a high level of reproducibility about the same case. @*Conclusion@#The findings of this study will be utilized for the development of training materials for SPs, so they can participate in the administration of a fair and reliable practical examination of the NDLE.

6.
The Journal of Korean Academy of Prosthodontics ; : 185-192, 2020.
Artigo | WPRIM | ID: wpr-837261

RESUMO

Purpose@#The purpose of this study is to investigate dental students’ self-perception of clinical care ability after a denture treatment experience. @*Materials and methods@#Of the 58 fourth-year students at the dental school in 2019, 50 students completed the questionnaire concerning their denture treatment session, including treatment planning and pre-prosthetic treatment (4 questions), clinical and laboratory procedures (20 questions), and students’ opinions on clinical denture education (4 questions). Each question was answered on a five-point scale, of which points four and five, “agree” and “strongly agree” respectively, were classified as positive responses while points one and two, “disagree” and “strongly disagree” respectively, were classified as negative. @*Results@#All the items on clinical and laboratory procedures received a positive response rate of over 60%, and the overall self-perception of the students appeared to be positive. However, the questions on the ability to perform denture treatment independently after graduation received only 48% of positive answer. Those on patient management, explanations of denture precautions, customized tray production, boxing, and work model production were answered with the highest positive response rate whereas those on treatment planning, final impression acquisition, and surveying, were the lowest in each session. @*Conclusion@#The dental students with experience in denture treatment generally have a positive opinion of their clinical care ability, but further education may be necessary to improve their ability to treat their patients independently.

7.
The Journal of Korean Academy of Prosthodontics ; : 31-36, 2019.
Artigo em Coreano | WPRIM | ID: wpr-719553

RESUMO

As the number of elderly population increases, the proportion of edentulous patients is increasing, and the demand for traditional dentures will also increase. Arranging the artificial teeth according to the relationship and shape of the upper and lower alveolar ridge is an important factor increasing the stability of the denture. This case is a 79 year old female patient who wishes to make denture covered by national health insurance for psychological and economical reasons. With the alveolar bone severely atrophic, the dental CAD software was used for accurate diagnosis and the posterior teeth were arranged in a cross bite according to the interalveolar crest line angle by the program. After completion, the denture showed adequate stability and maintenance in periodic examinations and treatment, and the patient also expressed high satisfaction.


Assuntos
Idoso , Feminino , Humanos , Processo Alveolar , Prótese Total , Dentaduras , Diagnóstico , Má Oclusão , Programas Nacionais de Saúde , Reabilitação , Dente , Dente Artificial
8.
The Journal of Korean Academy of Prosthodontics ; : 397-404, 2019.
Artigo em Coreano | WPRIM | ID: wpr-761452

RESUMO

Bone and soft tissue conditions are important for successful implant treatment. But, the placement itself is also very important. Implants which is installed in the wrong position result in the biological, esthetical and mechanical problems. In order to place an implant in the correct position, the final restoration and diagnostic wax-up should be considered prior to the surgery. If the artificial teeth for the interim denture are directly transferred from the diagnostic wax-up, the operator can try the form of diagnostic wax-up in the mouth. If the surgical template is produced by duplicating the interim denture, the implant can be placed in the planned position. In this case, the polymethyl methacrylate (PMMA) artificial tooth was precisely milled by the digital duplication of diagnostic wax-up. And interim denture was fabricated by using these milled teeth. After the patient adapted for a sufficient period, the implant was placed at the planned position with surgical template produced by duplicating the interim denture. After confirming sufficient osseointegration, the final prostheses were made to reflect the shape of diagnostic wax-up. Through this procedure, the satisfactory functional and esthetic outcome could be acquired.


Assuntos
Humanos , Implantes Dentários , Prótese Dentária , Dentaduras , Boca , Osseointegração , Polimetil Metacrilato , Próteses e Implantes , Reabilitação , Dente , Dente Artificial
9.
The Journal of Korean Academy of Prosthodontics ; : 254-262, 2019.
Artigo em Coreano | WPRIM | ID: wpr-761432

RESUMO

As implant can be covered by National Health Insurance Service (NHIS), it was increased the interest in the removable partial denture (RPD) with the surveyed fixed prosthesis supported by implant fixture. To achieve predictable result, it needs the prudent implant planning by basic principles of RPD and patient's residual ridge. This 67 years old age male had a few unilateral remaining teeth, and hoped the treatment covered by NHIS. As using CAD software, the position of implant is planned with regarding to occlusal table of provisional denture, basic principles of RPD, and resorbed residual ridge. The definitive prostheses can ensure the stability and retention of removable prosthesis. When planning implant fixed prostheses, the digital technique was utilized to consider basic principle of RPD and resorbed residual ridge. As a result, it provided satisfactory prostheses.


Assuntos
Humanos , Masculino , Prótese Parcial Removível , Dentaduras , Esperança , Programas Nacionais de Saúde , Próteses e Implantes , Dente
10.
Restorative Dentistry & Endodontics ; : e29-2019.
Artigo em Inglês | WPRIM | ID: wpr-761309

RESUMO

Endodontic microsurgery is defined as the treatment performed on the root apices of an infected tooth, which was unresolved with conventional root canal therapy. Recently, the advanced technology in 3-dimensional model reconstruction based on computed tomography such as cone beam computed tomography has opened a new avenue in application of personalized, accurate diagnosis and has been increasingly used in the field of dentistry. Nevertheless, direct intra-oral localization of root apex based on the 3-dimensional information is extremely difficult and significant amount of bone removal is inevitable when freehand surgical procedure was employed. Moreover, gingival flap and alveolar bone fenestration are usually required, which leads to prolonged time of surgery, thereby increasing the chance of trauma as well as the risk of infection. The purpose of this case report is to present endodontic microsurgery using the guide template that can accurately target the position of apex for the treatment of an anterior tooth with calcified canal which was untreatable with conventional root canal therapy and unable to track the position of the apex due to the absence of fistula.


Assuntos
Humanos , Apicectomia , Tomografia Computadorizada de Feixe Cônico , Odontologia , Diagnóstico , Fístula , Microcirurgia , Impressão Tridimensional , Tratamento do Canal Radicular , Dente
11.
The Journal of Advanced Prosthodontics ; : 77-84, 2017.
Artigo em Inglês | WPRIM | ID: wpr-179527

RESUMO

PURPOSE: The aim of this study was to compare the surface roughness of zirconia when using Zircos E etching system (ZSAT), applying a nitric acid-hydrofluoric acid compound as a pretreatment agent, and also to compare the shear bonding strength according to different resin cements. MATERIALS AND METHODS: ZSAT, air abrasion, and tribochemical silicacoating were applied on prepared 120 zirconia specimens (10 mm in diameter, 7 mm in height) using CAD/CAM. Each 12 specimens with 4 different resin cements (Panavia F 2.0, Rely X Unicem, Superbond C&B, and Hot bond) were applied to test interfacial bond strength. The statistical analysis was performed using SAS 9.1 (SAS Institute Inc., Cary, NC, USA). The results are as follows: after application of the ZSAT on the zirconia specimens, surface roughness value after 2-hour etching was higher than those after 1- and 3-hour etching on SEM images. RESULTS: For Superbond C&B and Rely X Unicem, the specimens treated with ZSAT showed higher shear bond strength values than those treated with air abrasion and tribochemical silicacoating system. Regarding the failure mode of interface over cement and zirconia surface, Rely X Unicem and Hot bond showed cohesive failures and Panavia F 2.0 and Superbond C&B showed mixed failures. CONCLUSION: Zircos E etching system in zirconia restoration could increase its shear bond strength. However, its long term success rate and clinical application should be further evaluated.


Assuntos
Adesivos , Cimentos de Resina
12.
The Journal of Korean Academy of Prosthodontics ; : 264-271, 2017.
Artigo em Inglês | WPRIM | ID: wpr-90428

RESUMO

PURPOSE: The purpose of this study is to investigate the differences in bond strength of four different indirect composites to the gold alloy and Ni-Cr alloy according to type of metal surface treatment after water storage. MATERIALS AND METHODS: Type IV gold alloy and Ni-Cr alloy were used for casting alloy while four types of indirect composite resins (Gradia, Tescera Sinfony and in;joy) were used in this study. Metal specimens were produced by casting and total of 240 specimens (60 specimens per one indirect composite group) were prepared. After bonding indirect composite resin and undergoing 24 hours of polymerization, customized jig was attached to the metal specimen and shear bond strength were measured using universal testing machine. Also, differences in shear bond strength before and after water storage for 240 hours were also measured. RESULTS: In the measurement of shear bond strength according to the metal surface treatments, bead group showed high strength followed by loop and flatting group (P<.05). After being stored in water bath for 240 hours, Gradia showed statistically significant high bond strength compared to other indirect composite resins in all groups (P<.05). CONCLUSION: Shearbond strength was found to be different according to type of metal surface treatment and type of metal used after storage in water. Further studies need to be developed for clinical practices as three are still problems of microleakage, stain or wear.


Assuntos
Ligas , Banhos , Resinas Compostas , Polimerização , Polímeros , Água
13.
The Journal of Advanced Prosthodontics ; : 152-158, 2017.
Artigo em Inglês | WPRIM | ID: wpr-71188

RESUMO

PURPOSE: The purpose of this study was to evaluate the influence of different coping thicknesses and veneer ceramic cooling rates on the failure load of zirconia-ceramic crowns. MATERIALS AND METHODS: Zirconia copings of two different thicknesses (0.5 mm or 1.5 mm; n=20 each) were fabricated from scanning 40 identical abutment models using a dental computer-aided design and computer-aided manufacturing system. Zirconia-ceramic crowns were completed by veneering feldspathic ceramics under different cooling rates (conventional or slow, n=20 each), resulting in 4 different groups (CONV05, SLOW05, CONV15, SLOW15; n=10 per group). Each crown was cemented on the abutment. 300,000 cycles of a 50-N load and thermocycling were applied on the crown, and then, a monotonic load was applied on each crown until failure. The mean failure loads were evaluated with two-way analysis of variance (P=.05). RESULTS: No cohesive or adhesive failure was observed after fatigue loading with thermocycling. Among the 4 groups, SLOW15 group (slow cooling and 1.5 mm chipping thickness) resulted in a significantly greater mean failure load than the other groups (P<.001). Coping fractures were only observed in SLOW15 group. CONCLUSION: The failure load of zirconia-ceramic crowns was significantly influenced by cooling rate as well as coping thickness. Under conventional cooling conditions, the mean failure load was not influenced by the coping thickness; however, under slow cooling conditions, the mean failure load was significantly influenced by the coping thickness.


Assuntos
Adesivos , Cerâmica , Desenho Assistido por Computador , Coroas , Fadiga
14.
The Journal of Advanced Prosthodontics ; : 363-371, 2016.
Artigo em Inglês | WPRIM | ID: wpr-180736

RESUMO

PURPOSE: On maxillofacial tumor patients, oral implant placement prior to postoperative radiotherapy can shorten the period of prosthetic reconstruction. There is still lack of research on effects of post-implant radiotherapy such as healing process or loading time, which is important for prosthodontic treatment planning. Therefore, this study evaluated the effects of post-implant local irradiation on the osseointegration of implants during different healing stages. MATERIALS AND METHODS: Custom-made implants were placed bilaterally on maxillary posterior edentulous area 4 weeks after extraction of the maxillary first molars in Forty-eight Sprague-Dawley rats. Experimental group (exp.) received radiation after implant surgery and the other group (control) didn't. Each group was divided into three sub-groups according to the healing time (2, 4, and 8 week) from implant placement. The exp. group 1, 2 received 15-Gy radiation 1 day after implant placement (immediate irradiation). The exp. group 3 received 15-Gy radiation 4 weeks after implant placement (delayed irradiation). RESULTS: The bone mineral density (BMD) was significantly lower in the immediate irradiation groups. BMD was similar in the delayed irradiation group and the control group. The irradiated groups exhibited a lower bone-to-implant contact ratio, although the difference was not statistically significant. The irradiated groups also exhibited a significantly lower bone volume and higher empty lacuna count than the control groups. No implant failure due to local irradiation was found in this study. CONCLUSION: Within the limits of this study, the timing of local irradiation critically influences the bone healing mechanism, which is related to loading time of prostheses.


Assuntos
Humanos , Densidade Óssea , Neoplasias de Cabeça e Pescoço , Dente Molar , Osseointegração , Projetos Piloto , Próteses e Implantes , Radioterapia , Ratos Sprague-Dawley
15.
The Journal of Korean Academy of Prosthodontics ; : 387-392, 2016.
Artigo em Coreano | WPRIM | ID: wpr-169356

RESUMO

PURPOSE: The aim of this study was to investigate the effects of grooved abutments on abutment screw loosening. MATERIALS AND METHODS: This study was conducted to evaluate the abutment screw loosening after 6 months for 50 patients (51 implants) treated at the department of Prosthodontics in Yonsei University Dental Hospital from March, 2015 to July, 2015. A control group with non-grooved abutment consists of 30 implants, and an experimental group with grooved abutment consists of 21 implants. Astra, Straumann, Implantium, Osstem system were used in the study. The abutments with loose screws cases after a period of 6 months has been investigated, with two kinds of measurements: 1) measuring the additional rotational angle on abutment during placement with the same force, 2) measuring the PTV on bucco-cervical area of implant crown. All data collected has been analyzed by normality test followed by Mann-Whitney test using SPSS program. RESULTS: No complications were reported after 6 months for the 51 implants. Abutment screw loose and crown fracture have not been seen in the study groups. The data collected from the two measurements showed no significant differences between the two groups with P-value 0.576 (average= control group: 7.35°, experimental group: 4.75°) for the additional rotational angle measurement and with P-value 0.767 for PTV. CONCLUSION: There are no significant differences between the grooved and non-grooved abutment in screw stability. However, further studies with long-term follow-ups and larger group of patients is needed in order to investigate the effects of grooved abutment on screw stability.


Assuntos
Humanos , Coroas , Seguimentos , Prostodontia
16.
The Journal of Korean Academy of Prosthodontics ; : 305-311, 2014.
Artigo em Inglês | WPRIM | ID: wpr-201571

RESUMO

PURPOSE: When the full veneer crown was treated in the tooth with abfraction lesion due to various causes, the prognosis of it may be compromised according to the location of the finish line, but there is few study about the location of its buccal finish line. The purpose of this study was to investigate the effect of location of the finish line of the full veneer crown on stress distribution of the tooth with abfraction lesion. MATERIALS AND METHODS: The two dimensional finite element model was developed to express tooth, surrounding tissue and full veneer crown. The stress distribution under eccentric 144 N occlusal load was analyzed using finite element analysis. The location of finish line was set just at the lower border of the lesion (Group 0), 1 mm (Group 1) and 2 mm (Group 2) below the lower border of the lesion. RESULTS: In the Group 0, von Mises stress was concentrated at the finish line and the apex of the lesion. Also, the stress at the bucal finish line propagated to the lingual side. In the Group 1 and Group 2, stress distribution was similar each other. Stress was concentrated at the apex of lesion, but the stress at the buccal finish line did not propagate to the lingual side. That implied decrease of the possibility of horizontal crown fracture. CONCLUSION: Full veneer crown alleviated the stress concentrated at the apex of the abfraction lesion, when the finish line of full veneer crown was set below the lower border of abfraction lesion.


Assuntos
Coroas , Análise de Elementos Finitos , Prognóstico , Dente
17.
The Journal of Korean Academy of Prosthodontics ; : 112-118, 2012.
Artigo em Coreano | WPRIM | ID: wpr-229221

RESUMO

PURPOSE: The purpose of this study was to evaluate the difference in shear bonding strength between resin cements to dental materials when a universal primer (Monobond plus) was applied in place of a conventional primer. MATERIALS AND METHODS: Four groups of testing materials: gold alloy (Argedent Euro, n = 16), non precious metal (T-4, n = 20), zirconia (Cercon, n = 20) and glass ceramic (IPS e.max press, n = 20), were fabricated into discs, which were embedded in an acrylic resin matrix. The gold alloy specimens were airborne-particle abraded, 8 of the specimens were coated with Metal primer II, while the remaining 8 specimens were coated with Monobond plus. The non precious and zirconia specimen were airborne-particle abraded then, the control group received Alloy primer coating, while the other was coated with Monobond plus. Glass ceramic specimens were etched. 10 specimens were coated with Monobond-S and the remaining specimens were coated using Monobond plus. On top of the surface, Multilink N was polymerized in a disc shape. All of the specimens were thermal cycled before the shear bonding strength was measured. Statistical analysis was done with Two sample t-test or Mann-Whitney U test (alpha=.05). RESULTS: There were no significant differences in bonding strength depending on the type of primer used in the gold alloy and glass ceramic groups (P>.05), however, the bonding strengths of resin cements to non precious metal and zirconia groups, were significantly higher when the alloy primer was used (P<.05). CONCLUSION: Within the limitations of this study, improvement of universal primers which can be applied to all types of restorations is recommended to precious metals and zirconia ceramics. But, the bond strengths of non precious metals and zirconia ceramics were significantly lower when compared to a 10-MDP primer. More research is needed to apply universal primers to all types of restorations.


Assuntos
Ligas , Cerâmica , Colódio , Materiais Dentários , Vidro , Hipogonadismo , Metais , Metacrilatos , Doenças Mitocondriais , Oftalmoplegia , Polímeros , Cimentos de Resina , Tionas , Zircônio
18.
The Journal of Advanced Prosthodontics ; : 227-234, 2012.
Artigo em Inglês | WPRIM | ID: wpr-174445

RESUMO

PURPOSE: The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS: Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method,simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (microepsilon) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS: The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION: Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study.


Assuntos
Animais , Experimentação Animal , Vértebra Cervical Áxis , Dente Pré-Molar , Implantes Dentários , Análise do Estresse Dentário , Carga Imediata em Implante Dentário , Mandíbula , Osseointegração , Projetos Piloto , Entorses e Distensões
19.
The Journal of Advanced Prosthodontics ; : 18-23, 2012.
Artigo em Inglês | WPRIM | ID: wpr-141481

RESUMO

PURPOSE: The purpose of this prospective study was to evaluate the effect of early loading on survival rate or clinical parameter of anodic oxidized implants during the 12-month postloading period. MATERIALS AND METHODS: Total 69 implants were placed in 42 patients. Anodic oxidized implants (GS II, Osstem Cor., Busan, Korea) placed on the posterior mandibles were divided into two groups, according to their prosthetic loading times: test group (2 to 6 weeks), and control group (3 to 4 months). The implant survival rates were determined during one-year postloading period and analyzed by Kaplan-Meier method. The radiographic peri-implant bone loss and periodontal parameters were also evaluated and statistically analyzed by unpaired t-test. RESULTS: Total 69 implants were placed in 42 patients. The cumulative postloading implant survival rates were 88.89% in test group, compared to 100% in control group (P.05). CONCLUSION: Within the limitation of the present study, implant survival was affected by early loading on the anodic oxidized implants placed on posterior mandibles during one-year follow-up. Early implant loading did not influence peri-implant marginal bone loss, and periodontal parameters.


Assuntos
Humanos , Seguimentos , Mandíbula , Estudos Prospectivos , Taxa de Sobrevida
20.
The Journal of Advanced Prosthodontics ; : 18-23, 2012.
Artigo em Inglês | WPRIM | ID: wpr-141480

RESUMO

PURPOSE: The purpose of this prospective study was to evaluate the effect of early loading on survival rate or clinical parameter of anodic oxidized implants during the 12-month postloading period. MATERIALS AND METHODS: Total 69 implants were placed in 42 patients. Anodic oxidized implants (GS II, Osstem Cor., Busan, Korea) placed on the posterior mandibles were divided into two groups, according to their prosthetic loading times: test group (2 to 6 weeks), and control group (3 to 4 months). The implant survival rates were determined during one-year postloading period and analyzed by Kaplan-Meier method. The radiographic peri-implant bone loss and periodontal parameters were also evaluated and statistically analyzed by unpaired t-test. RESULTS: Total 69 implants were placed in 42 patients. The cumulative postloading implant survival rates were 88.89% in test group, compared to 100% in control group (P.05). CONCLUSION: Within the limitation of the present study, implant survival was affected by early loading on the anodic oxidized implants placed on posterior mandibles during one-year follow-up. Early implant loading did not influence peri-implant marginal bone loss, and periodontal parameters.


Assuntos
Humanos , Seguimentos , Mandíbula , Estudos Prospectivos , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA