Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. bras. cir. cardiovasc ; 37(5): 680-687, Sept.-Oct. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1407300

RESUMO

ABSTRACT Introduction: Custodiol (histidine-tryptophan-ketoglutarate) and repetitive blood cardioplegia are the solutions for myocardial protection and cardiac arrest. In this study, we aimed to compare immunohistochemical analysis, clinical outcomes, and cardiac enzyme values of Custodiol and blood cardioplegia groups. Methods: This was a randomized prospective study consisting of 2 groups and 20 patients, 10 patients for each group, who underwent mitral and mitral/tricuspid valve surgery. Group 1 was formed for Custodiol cardioplegia and group 2 for blood cardioplegia. Perioperative and postoperative cardiac events were recorded, cardiac enzymes were analyzed with intervals, and myocardial samples were taken for immunohistochemical analysis. Recorded data were statistically evaluated. Results: There was no significant difference for the Custodiol and blood cardioplegia groups in perioperative and postoperative cardiac performance and adverse events. Cardiac enzyme analysis showed no significant difference between groups. However, two parameters (eNOS, Bcl-2) were in favor of the Custodiol group in immunohistochemical studies. Custodiol performed better in cellular oxidative stress resistance and cellular viability. Conclusion: Clinical outcomes and cardiac enzyme analysis results were similar regarding myocardial protection. However, Custodiol performed better in the immunohistochemical analysis.

2.
Rev. bras. cir. cardiovasc ; 34(3): 285-289, Jun. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1013466

RESUMO

Abstract Introduction: This study aimed to evaluate the feasibility and efficacy of robotically assisted, minimally invasive mitral valve surgery combined with left atrial reduction for mitral valve surgery and elimination of atrial fibrillation (AF). Methods: Eleven patients with severe mitral regurgitation, AF, and left atrial enlargement who underwent robotic, minimally invasive surgery between May 2013 and March 2018 were evaluated retrospectively. The da Vinci robotic system was used in all procedures. The patients' demographic data, electrocardiography (ECG) findings, and pre- and postoperative transthoracic echocardiography findings were analyzed. During follow up ECG was performed at postoperative 3, 6, and 12 months additionally at the 3rd month trans thoracic echocardiography was performed and functional capacity was also evaluated for all patients. Results: All patients underwent robotic-assisted mitral valve surgery with radiofrequency ablation and left atrial reduction. Mean age was 45.76±16.61 years; 7 patients were male and 4 were female. Preoperatively, mean left atrial volume index (LAVI) was 69.55±4.87 mL/m2, ejection fraction (EF) was 54.62±8.27%, and pulmonary artery pressure (PAP) was 45.75±9.42 mmHg. Postoperatively, in hospital evaluation LAVI decreased to 48.01±4.91 mL/m2 (P=0.008), EF to 50.63±10.13% (P>0.05), and PAP to 39.02±3.11 mmHg (P=0.012). AF was eliminated in 8 (72%) of the 11 patients at the 1st postoperative month. There were significant improvements in functional capacity and no mortality during follow-up. Conclusion: Left atrial reduction and radiofrequency ablation concomitant with robotically assisted minimally invasive mitral valve surgery can be performed safely and effectively to eliminate AF and prevent recurrence.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Ablação por Radiofrequência/métodos , Átrios do Coração/cirurgia , Valva Mitral/cirurgia , Fatores de Tempo , Ecocardiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Seguimentos , Resultado do Tratamento , Estatísticas não Paramétricas
3.
Rev. bras. cir. cardiovasc ; 33(5): 443-447, Sept.-Oct. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-977454

RESUMO

Abstract Introduction: Various surgical procedures for minimally invasive cardiac surgery have been described in recent decades as alternatives to median sternotomy. Cardiopulmonary bypass via femoral arterial and venous cannulation is the foundation of these procedures. In this study, we evaluated the mid-term outcomes of femoral cannulation performed with U-suture technique in patients undergoing robotic heart surgery. Methods: A total of 216 patients underwent robotic-assisted cardiac surgery between January 2013 and April 2017. Cardiopulmonary bypass was performed via femoral artery, jugular, and femoral vein cannulation, and a Chitwood clamp was used for aortic occlusion. A total of 192 patients attended the outpatient follow-up, and femoral arterial and venous flow pattern was examined using Doppler ultrasound (DUS) in 145 patients. Results: Hospital mortality occured in 4 of the 216 (1.85%) cases, but there was no late mortality in this patient group. Postoperatively, seroma (n=9, 4.69%) and cannulation site infection (n=3, 1.56%) were managed with outpatient treatment. DUS in 145 patients revealed triphasic flow pattern in the common femoral arteries in all patients except for 2 (1.38%). These patients were determined to have asymptomatic arterial stenosis. Chronic recanalized thrombus in the common femoral vein was also detected in 2 (1.38%) patients. Conclusion: Femoral artery cannulation with the U-suture technique can be successfully performed in robotic-assisted cardiac surgery, with good mid-term results.


Assuntos
Humanos , Masculino , Feminino , Adulto , Arteriopatias Oclusivas/cirurgia , Ponte Cardiopulmonar/métodos , Procedimentos Cirúrgicos Robóticos , Velocidade do Fluxo Sanguíneo , Ponte Cardiopulmonar/efeitos adversos , Seguimentos , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos , Artéria Femoral , Veia Femoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA