Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Braz. j. med. biol. res ; 38(5): 723-730, May 2005. ilus, tab
Artigo em Inglês | LILACS | ID: lil-400955

RESUMO

Beta-2-agonists have been widely used by asthmatic subjects to relieve their obstructive symptoms. However, there are reports that continuous use could lead to loss of bronchial protection and exacerbation of asthma symptoms. We evaluated the effect of two regimens of salbutamol administration (twice and five times a week) in a model of chronic airway inflammation in male Hartley guinea pigs (protocol starting weight: 286 ± 30 g) induced by repeated exposures to aerosols of ovalbumin (OVA). After sensitization, guinea pigs were exposed to aerosols of 0.1 mg/ml salbutamol solution twice a week (OVA + S2x, N = 7) or five times a week (OVA + S5x, N = 8). We studied allergen-specific (OVA inhalation time) and -nonspecific (response to methacholine) respiratory system responsiveness. Seventy-two hours after the last OVA challenge, guinea pigs were anesthetized and tracheostomized, respiratory system resistance and elastance were measured and a dose-response curve to inhaled methacholine chloride was obtained. Specific IgG1 was also quantified by the passive cutaneous anaphylactic technique. OVA-sensitized guinea pigs (N = 8) showed reduction of the time of OVA exposure before the onset of respiratory distress, at the 5th, 6th and 7th exposures (P < 0.001). The OVA + S2x group (but not the OVA + S5x group) showed a significant increase in OVA inhalation time. There were no significant differences in pulmonary responsiveness to methacholine among the experimental groups. OVA + S2x (but not OVA + S5x) animals showed a decrease in the levels of IgG1-specific anaphylactic antibodies compared to the OVA group (P < 0.05). Our results suggest that, in this experimental model, frequent administration of ß2-agonists results in a loss of some of their protective effects against the allergen.


Assuntos
Cobaias , Animais , Masculino , Agonistas Adrenérgicos beta/administração & dosagem , Albuterol/administração & dosagem , Asma/tratamento farmacológico , Doença Crônica , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Cloreto de Metacolina , Ovalbumina , Fatores de Tempo
2.
Braz. j. med. biol. res ; 35(10): 1133-1137, Oct. 2002. ilus, graf
Artigo em Inglês | LILACS | ID: lil-326236

RESUMO

Techniques for collecting exhaled nitric oxide (ENO) recommend the use of antibacterial filters of 0.3 æm. The aim of the present study was to compare the measurements of ENO obtained with two different filtering devices. Air samples from 17 asthmatic and 17 non-asthmatic subjects were collected by a recommended off-line technique using two different mouthpieces: 1) the Sievers disposable tool (A) under a breathing pressure of 18 cmH2O, and 2) a mouthpiece containing a HEPA filter (B) under a breathing pressure of 12 cmH2O. The nitric oxide samples were collected into an impermeable reservoir bag. Values for ENO were compared using two-way repeated measures ANOVA followed by the Tukey test. Agreement was assessed by Bland-Altman analysis. ENO values obtained with mouthpieces A and B were comparable for asthmatic (mean ± SEM, 42.9 ± 6.9 vs 43.3 ± 6.6 ppb) and non-asthmatic (13.3 ± 1.3 vs 13.7 ± 1.1 ppb) subjects. There was a significant difference in ENO between asthmatics and non-asthmatics using either mouthpiece A (P<0.001) or B (P<0.001). There was a positive correlation between mouthpiece A and mouthpiece B for both groups. The Bland-Altman limits of agreement were considered to be acceptable. Mouthpiece B was less expensive than A, and these data show that it can be used without compromising the result. Our data confirm reports of higher ENO values in the presence of airway inflammation


Assuntos
Humanos , Asma , Testes Respiratórios , Filtração , Óxido Nítrico , Análise de Variância , Estudos de Casos e Controles
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA