Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Ultrasonography ; (12)2003.
Artigo em Chinês | WPRIM | ID: wpr-541247

RESUMO

Objective To investigate the diagnosis value of sonography for the meniscus lesions. Methods Sixty-six menisci of thirty-one patients examined by ultrasonography were compared with the arthroscopic operation or surgical findings. Results For all meniscal lesions,the ultrasound detecting gave an accuracy of (92.4)%,sensitivity of (94.1)%,specificity of (90.6)%,positive predictive value of (91.4)%,negative predictive value of (93.5)%.For medial meniscal lesions,the ultrasonography gave an accuracy of (87.9)%.For lateral meniscal lesions,the ultrasonography gave an accuracy of (97.0)%. The accuracies of locating the meniscal lesions and identifying the meniscal type were (85.3)% and (76.5)%,respectively.Using the miniwidth of meniscus at the midbody exceeds 15 mm as criterion,the accuracy of sonography indicating discoid meniscus was (88.9)%. Conclusions Ultrasonography can make relatively accurate diagnosis for meniscus lesions with its advantage of noninvasive convenience,and can be used as an auxiliary means to detect meniscus lesions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA