Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Keimyung Medical Journal ; : 125-128, 2021.
Artigo em Inglês | WPRIM | ID: wpr-917030

RESUMO

Lower back pain and sciatica are common symptoms in pregnancy. Treatment options for these conditions include physical therapy, medication, interventional treatment, and surgery. This case report involved a 32 weeks pregnant woman, who visited the emergency room with a three day history of lower back and right leg pain and a visual analogue scale (VAS) score of 9 - 10. Spinal computed tomography revealed lumbar 4/5 and 5/S1 disc protrusions. An epidural catheter was placed around the L3/4 vertebrae, and 6 ml of 0.15% ropivacaine was administered for pain control. Subsequently, her VAS score reduced to 2 - 3 and she was discharged five days later.

2.
Yeungnam University Journal of Medicine ; : 109-114, 2019.
Artigo em Inglês | WPRIM | ID: wpr-939349

RESUMO

BACKGROUND@#Transforaminal epidural block (TFEB) is an effective treatment option for radicular pain. To reduce complications from intravascular injection during TFEB, use of imaging modalities such as real-time fluoroscopy (RTF) or digital subtraction angiography (DSA) has been recommended. In this study, we investigated whether DSA improved the detection of intravascular injection during TFEB at the whole spine level compared to RTF.@*METHODS@#We prospectively examined 316 patients who underwent TFEB. After confirmation of final needle position using biplanar fluoroscopy, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under RTF; 30 s later, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under DSA.@*RESULTS@#Thirty-six intravascular injections were detected for an overall rate of 11.4% using RTF, with 45 detected for a rate of 14.2% using DSA. The detection rate using DSA was statistically different from that using RTF (p=0.004). DSA detected a significantly higher proportion of intravascular injections at the cervical level than at the thoracic (p=0.009) and lumbar (p=0.011) levels.@*CONCLUSION@#During TFEB at the whole spine level, DSA was better than RTF for the detection of intravascular injection. Special attention is advised for cervical TFEB, because of a significantly higher intravascular injection rate at this level than at other levels.

3.
Yeungnam University Journal of Medicine ; : 109-114, 2019.
Artigo em Inglês | WPRIM | ID: wpr-785312

RESUMO

BACKGROUND: Transforaminal epidural block (TFEB) is an effective treatment option for radicular pain. To reduce complications from intravascular injection during TFEB, use of imaging modalities such as real-time fluoroscopy (RTF) or digital subtraction angiography (DSA) has been recommended. In this study, we investigated whether DSA improved the detection of intravascular injection during TFEB at the whole spine level compared to RTF.METHODS: We prospectively examined 316 patients who underwent TFEB. After confirmation of final needle position using biplanar fluoroscopy, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under RTF; 30 s later, 2 mL of nonionic contrast medium was injected at a rate of 0.5 mL/s under DSA.RESULTS: Thirty-six intravascular injections were detected for an overall rate of 11.4% using RTF, with 45 detected for a rate of 14.2% using DSA. The detection rate using DSA was statistically different from that using RTF (p=0.004). DSA detected a significantly higher proportion of intravascular injections at the cervical level than at the thoracic (p=0.009) and lumbar (p=0.011) levels.CONCLUSION: During TFEB at the whole spine level, DSA was better than RTF for the detection of intravascular injection. Special attention is advised for cervical TFEB, because of a significantly higher intravascular injection rate at this level than at other levels.


Assuntos
Humanos , Analgesia , Angiografia Digital , Fluoroscopia , Agulhas , Estudos Prospectivos , Radiculopatia , Coluna Vertebral
4.
Clinical and Experimental Otorhinolaryngology ; : 40-49, 2019.
Artigo em Inglês | WPRIM | ID: wpr-739232

RESUMO

OBJECTIVES: Doppler optical coherence tomography (DOCT) is useful for both, the spatially resolved measurement of the tympanic membrane (TM) oscillation and high-resolution imaging. We demonstrated a new technique capable of providing real-time two-dimensional Doppler OCT image of rapidly oscillatory latex mini-drum and in vivo rat TM and ossicles. METHODS: Using DOCT system, the oscillation of sample was measured at frequency range of 1–4 kHz at an output of 15 W. After the sensitivity of the DOCT system was verified using a latex mini-drum consisting of a 100 μm-thick latex membrane, changes in displacement of the umbo and contacted area between TM and malleus in normal and pathologic conditions. RESULTS: The oscillation cycles of the mini-drum for stimulus frequencies were 1.006 kHz for 1 kHz, 2.012 kHz for 2kHz, and 3.912 kHz for 4 kHz, which means that the oscillation cycle of the mini-drum become short in proportional to the frequency of stimuli. The oscillation cycles of umbo area and the junction area in normal TM for frequencies of the stimuli showed similar integer ratio with the data of latex mini-drum for stimuli less than 4 kHz. In the case of middle ear effusion condition, the Doppler signal showed a tendency of attenuation in all frequencies, which was prominent at 1 kHz and 2 kHz. CONCLUSION: The TM vibration under sound stimulation with frequencies from 1 kHz to 4 kHz in normal and pathologic conditions was demonstrated using signal demodulation method in in vivo condition. The OCT technology could be helpful for functional and structural assessment as an optional modality.


Assuntos
Animais , Ratos , Orelha Média , Látex , Martelo , Membranas , Métodos , Otite Média com Derrame , Tomografia de Coerência Óptica , Membrana Timpânica , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA