Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo em Inglês | LILACS, BBO | ID: biblio-1180870

RESUMO

ABSTRACT Objective: To compare the effect of Maleic acid and Irritrol (combination of Chlorhexidine & Ethylenediaminetetraacetic acid) irrigation on the sealing ability of Biodentine when used as root-end filling material. Material and Methods: Thirty single-rooted human premolars were subjected to standardized root canal instrumentation and were irrigated with 2.5% Sodium Hypochlorite (NaOCl) after each instrument change. Apical root resections were done by removing 3 mm of the apex at a 90° angle to the long axis of the root with a diamond bur. The root end cavity preparation was done using ultrasonic tips at a low power setting under water coolant. They were randomly divided into 3 groups (n=10). Group 1 was irrigated with 7% Maleic acid, Group 2 was irrigated with Irritrol, and Group 3 was irrigated with 0.9% Saline (Control). Then, the root end cavities of all the samples were restored with Biodentine and were subjected to leakage analysis using a glucose filtration test. The mean values for each group were calculated and the obtained data was statistically analysed using ANOVA with post-hoc Tukey's test, ANOVA with post-hoc Games-Howell test and repeated measures ANOVA with post-hoc Bonferroni test. Results: The specimens irrigated with Irritrol showed least microleakage as compared to 7% Maleic acid and 0.9% Saline. Conclusion: A regimen involving irrigation of the root-end cavity with Irritrol followed by root-end filling with Biodentine can improve the apical seal.


Assuntos
Humanos , Ácidos , Preparo de Canal Radicular/instrumentação , Materiais Dentários , Cavidade Pulpar , Dente Pré-Molar , Radiografia Dentária/instrumentação , Análise de Variância , Índia
2.
Artigo em Inglês | LILACS, BBO | ID: biblio-1056882

RESUMO

Abstract Objective: To compare the fluoride release from Conventional Glass Ionomer Cement (GIC), Resin Modified GIC (RMGIC), and Cention N Alkasite Material. Material and Methods: Forty- five disc-shaped specimens of three different restorative materials (Conventional GIC, RMGIC, and Alkasite material) were made and divided into 3 groups (n=15). Fluoride release was evaluated at the end of Day 1, 7, 14, and Day 28 using fluoride ion-selective electrode. Intergroup and Intra-group analysis was done using One-way ANOVA with a Post-hoc test. A p-value of <0.05 was considered statistically significant. Results: Cention showed more fluoride release (in parts per million) than GIC and RMGIC at increased time duration. However, at the end of day 1, there was lesser fluoride release with Cention, as compared with the other groups. Conclusion: The new Alkasite restorative material showed promising results in terms of fluoride release and is better than GIC and RMGIC at increased time duration.


Assuntos
Técnicas In Vitro/métodos , Eletrodos Seletivos de Íons , Fluoretos/química , Cimentos de Ionômeros de Vidro , Teste de Materiais/instrumentação
3.
Artigo em Inglês | LILACS, BBO | ID: biblio-1056885

RESUMO

Abstract Objective: To compare the color stability of Cention N, Fuji IX GP Extra, and Fuji IX GP after thermocycling. Material and Methods: Ten discs of each material of dimension 10 x 1 mm were prepared using a split mold. The preparations of the specimens were done according to the powder/liquid ratio as recommended by the manufacturers [4.6:1, 3.4:1 and 3.6:1 for the groups I, II, and III, respectively]. After setting, the samples were retrieved, and the thickness of each specimen was measured using a micrometer at five different locations. The specimens with variations in thickness, porosity or cracks were discarded and thus not included in the study. The selected specimens were stored in distilled water for 24 hours prior to testing. The prepared specimens were thermocycled at 5°C and 55°C, with a dwell time of 15 seconds for 250 or 500 cycles. Subsequently, the color parameters of the discs were measured using a spectrophotometer. The data were analyzed using two way ANOVA test, and a p-value <0.001 was considered. Results: Thermocycling resulted in changes in the color of both Glass Ionomer cement and Cention N (p<0.001). Among the materials tested, Cention N showed superior color stability. Conclusion: Cention N exhibited better color stability compared to Glass ionomer cements.


Assuntos
Espectrofotometria/métodos , Materiais Dentários , Estética Dentária , Cimentos de Ionômeros de Vidro , Análise de Variância , Índia
4.
Artigo em Inglês | IMSEAR | ID: sea-148744

RESUMO

Endodontically treated teeth with the loss of coronal tooth structure when left untreated for a long period may cause supraeruption, drifting, tipping, and rotation of adjacent and opposing teeth. This may be challenging to the clinician, when fabricating a crown because of inadequate interocclusal space. This case report describes a simple technique to restore an endodontically treated maxillary first premolar with the loss of coronal tooth structure and lack of interocclusal space. The maxillary first premolar had a single root canal and was endodontically treated. The lower premolar had supraerupted reducing the interocclusal space. A minimally invasive and esthetic technique was used to restore the tooth with limited interocclusal clearance. The tooth was restored with a Richmond crown, which had the morphology of a canine instead of a premolar. Thus, the tooth was salvaged by changing the morphology of the crown and the desired functional and esthetic results were obtained.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA