Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Korean Journal of Obesity ; : 36-43, 2015.
Artigo em Coreano | WPRIM | ID: wpr-761602

RESUMO

BACKGROUND: Metabolic syndrome is associated with type 2 diabetes and cardiovascular disease in patients with prediabetes. The aim of this study was to investigate and compare WHtR (Waist-to-Height Ratio) as a predictor of metabolic syndrome with other anthropometric indices as in Body Mass Index (BMI), Waist Circumference (WC) and Waist to Hip Ratio (WHR) in prediabetes. METHODS: A total of 816 subjects with prediabetes were recruited from a community based Cohort Study. Receiver operating characteristic (ROC) curve was performed to find the optimal cutoff value of WHtR. Area under the curve (AUC) was calculated for each anthropometric index and correlation coefficient between WHtR and various dermographic and clinical factors was calculated. RESULTS: WHtR had a significant correlation with metabolic parameters except for fasting glucose and increased with increasing number of risk factors for metabolic syndrome. AUC of WHtR was significantly higher than that of other anthropometric indices. The optimal cutoff value of WHtR was 0.53 for metabolic syndrome in prediabetes. CONCLUSION: WHtR may be the simple and effective anthropometric index for predicting metabolic syndrome in prediabetic patients.


Assuntos
Humanos , Área Sob a Curva , Índice de Massa Corporal , Doenças Cardiovasculares , Estudos de Coortes , Jejum , Glucose , Estado Pré-Diabético , Fatores de Risco , Curva ROC , Circunferência da Cintura , Relação Cintura-Quadril
2.
Journal of Cardiovascular Ultrasound ; : 44-47, 2015.
Artigo em Inglês | WPRIM | ID: wpr-125861

RESUMO

Although pulmonary artery angiosarcoma is rare, it can be misdiagnosed as pulmonary embolism because of its similar clinical and diagnostic features. The diagnosis is often delayed and the misdiagnosis brings unnecessary treatment. Because we made a wrong diagnosis of pulmonary artery angiosarcoma as an acute pulmonary embolism, we did thrombolytic therapy which could be dangerous to the patient. In this case report, we focused on the clinical and echocardiographic features of pulmonary artery angiosarcoma which can be used in differentiating the diagnosis from pulmonary embolism.


Assuntos
Humanos , Diagnóstico , Erros de Diagnóstico , Ecocardiografia , Hemangiossarcoma , Artéria Pulmonar , Embolia Pulmonar , Terapia Trombolítica
3.
Korean Circulation Journal ; : 165-168, 2015.
Artigo em Inglês | WPRIM | ID: wpr-88028

RESUMO

Pathologic diagnosis of a cardiac mass is vital in determining the proper treatment modality. Open heart surgery or transesophageal echocardiography guided biopsy can be feasible methods to confirm the pathology. However, the former is highly invasive and both methods require general anesthesia. The introduction of intracardiac echocardiography (ICE) can provide good anatomic information of heart and does not require general anesthesia. In this report, we present two cases of cardiac tumors which were confirmed by percutaneous biopsy under the guidance of an ICE. The patients underwent cardiac biopsy without any complications.


Assuntos
Humanos , Anestesia Geral , Biópsia , Diagnóstico , Ecocardiografia , Ecocardiografia Transesofagiana , Coração , Neoplasias Cardíacas , Gelo , Patologia , Cirurgia Torácica
4.
Journal of Cardiovascular Ultrasound ; : 65-71, 2014.
Artigo em Inglês | WPRIM | ID: wpr-162341

RESUMO

BACKGROUND: Speckle-tracking echocardiography has been applied to measure right ventricular (RV) systolic function in various diseases. However, variations in strain measurement by different vendors have limited the application of these techniques for assessment of RV function. We sought to compare two methods for the assessment of RV systolic function in patients with acute pulmonary embolism (PE). METHODS: From August 2007 to May 2011, all consecutive PE patients were prospectively included in this cohort study. Global longitudinal strains of RV measured with EchoPAC PC software (GLSRV-EchoPAC; GE Medical Systems) and velocity vector imaging (GLSRV-VVI; Siemens Medical Systems) were recorded on the same set of echocardiographic images. RESULTS: We analyzed a total of 50 patients (12 males, 68 +/- 14 years) with acute PE in this study. GLSRV-EchoPAC and GLSRV-VVI were correlated (r = 0.793, p < 0.001) and they showed significant correlations with conventional echocardiographic parameters of RV systolic function and Log B-type natriuretic peptide (BNP) level. However, GLSRV-VVI only showed significant correlations with cardiac biomarkers as serum creatinine kinase-MB (r = 0.367, p = 0.010) and tropoinin-I concentrations (r = 0.294, p = 0.040). CONCLUSION: GLSRV-VVI and GLSRV-EchoPAC showed significant correlations with conventional echocardiographic parameters of RV systolic function and LogBNP value in patients with PE.


Assuntos
Humanos , Masculino , Biomarcadores , Estudos de Coortes , Comércio , Creatinina , Ecocardiografia , Ventrículos do Coração , Peptídeo Natriurético Encefálico , Estudos Prospectivos , Embolia Pulmonar
5.
Journal of the Korean Society of Hypertension ; : 45-54, 2013.
Artigo em Coreano | WPRIM | ID: wpr-212432

RESUMO

BACKGROUND: Exaggerated blood pressure (BP) response to exercise can be an independent risk factor for cardiovascular mortality and morbidity. The purpose of this study was to define the factor that effect on early systolic BP response to exercise. METHODS: We examined echocardiographic data, BP, heart rate from graded exercise test and brachial ankle pulse wave velocity (PWV) of 205 patients (137 men and 68 women; mean age 58 +/- 11 years; range, 19 to 83 years). Graded exercise test was conducted in BRUCE protocol. We define delta systolic blood pressure (SBP) as systolic BRUCE stage "n" BP minus baseline BP. RESULTS: Resting BP (127 +/- 16 mm Hg) was elevated to 171 +/- 26 mm Hg after peak graded exercise test. Resting heart rate (80 +/- 15 bpm) was increased to 146 +/- 27 bpm after peak graded exercise test. Stepwise regression test between baseline SBP, delta SBP, maximal SBP and left atrial volume index (LAVI) was done. Supine SBP, delta SBP, maximal SBP was not associated with LAVI (p > 0.5). But increased LAVI was significantly associated with delta SBP1 in woman (R2 = 0.192, p = 0.002). PWV was significantly associated with base line (R2 = 0.311, p < 0.01) and maximal SBP (R2 = 0.051, p < 0.01). However, PWV was not associated with delta SBP. CONCLUSIONS: LAVI and PWV were not associated with early SBP response to exercise. But in women, elevation of early SBP during exercise is associated with LAVI.


Assuntos
Feminino , Humanos , Masculino , Pressão Sanguínea , Teste de Esforço , Frequência Cardíaca , Coração , Análise de Onda de Pulso , Fatores de Risco
6.
Journal of the Korean Surgical Society ; : 366-370, 2002.
Artigo em Coreano | WPRIM | ID: wpr-68859

RESUMO

PURPOSE: We evaluated the feasibility of non-invasive imaging of estrogen receptors (ER) in primary breast cancer with iodine-123-labeled ER specific ligand (17alpha,20E)-21-[123I] iodo-19-nonpregna-1,3,5-(10), 20-tetraene-3, 17-diol using conventional nuclear medicine technique. METHODS: Before they underwent surgical management, planar scintigraphy and single-photon emission computed tomography (SPECT) were performed in 18 patients with proven primary breast cancer, after single IV injection of 5~10 mCi I-123-estradiol. The results were compared with those of immunohistochemical staining against ER of the surgical specimens. RESULTS: Planar and SPECT imaging showed hot uptake in nine of eighteen (50%) breast cancer patients. The results of ER immunohistochemistry were all positive in these patients. In the 9 cases of negative scintigraphy, 8 showed negative staining results but one showed positive staining results. Therefore, the overall concordance rate of ER scintigraphy and ER immunohistochemistry was 94.4% (17/18). CONCLUSION: ER scintigraphy using I-123-estradiol is a highly predictable in vivo technique to detect ER-positive breast cancer preoperatively. It has potential application as a reliable diagnostic modality and indicator of hormone therapy for breast cancer patients.


Assuntos
Humanos , Neoplasias da Mama , Mama , Estradiol , Estrogênios , Imuno-Histoquímica , Coloração Negativa , Medicina Nuclear , Cintilografia , Receptores de Estrogênio , Tomografia Computadorizada de Emissão , Tomografia Computadorizada de Emissão de Fóton Único
7.
Journal of Korean Breast Cancer Society ; : 108-112, 2002.
Artigo em Coreano | WPRIM | ID: wpr-28242

RESUMO

PURPOSE: We evaluated the feasibility of non-invasive imaging of estrogen receptors (ER) in primary breast cancer with iodine-123-labeled ER specific ligand (17alpha,20E)-21-[123I] iodo-19-nonpregna-1,3,5-(10), 20-tetraene-3, 17-diol using conventional nuclear medicine technique. METHODS: Before they underwent surgical management, planar scintigraphy and single-photon emission computed tomography (SPECT) were performed in 18 patients with proven primary breast cancer, after single IV injection of 5~10 mCi I-123-estradiol. The results were compared with those of immunohistochemical staining against ER of the surgical specimens. RESULTS: Planar and SPECT imaging showed hot uptake in nine of eighteen (50%) breast cancer patients. The results of ER immunohistochemistry were all positive in these patients. In the 9 cases of negative scintigraphy, 8 showed negative staining results but one showed positive staining results. Therefore, the overall concordance rate of ER scintigraphy and ER immunohistochemistry was 94.4% (17/18). CONCLUSION: ER scintigraphy using I-123-estradiol is a highly predictable in vivo technique to detect ER-positive breast cancer preoperatively. It has potential application as a re-liable diagnostic modality and indicator of hormone therapy for breast cancer patients.


Assuntos
Humanos , Neoplasias da Mama , Mama , Estradiol , Estrogênios , Imuno-Histoquímica , Coloração Negativa , Medicina Nuclear , Cintilografia , Receptores de Estrogênio , Tomografia Computadorizada de Emissão , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA