Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Indian J Ophthalmol ; 2011 Nov; 59(6): 471-474
Artigo em Inglês | IMSEAR | ID: sea-136230

RESUMO

Aim: To determine the risk factors for developing phacomorphic glaucoma in eyes with mature cataracts. Materials and Methods: This is a case-control study comprising of 90 eyes with phacomorphic glaucoma and 90 age- and sex-matched control eyes with mature cataracts without phacomorphic glaucoma. Patients with pre-existing glaucoma, previous intraocular surgery and /or absence of documented axial lengths were excluded from this study. Binary logistic regression analysis of the variables, axial length and anterior chamber depth, was performed. Anterior chamber depth of the contralateral eye was used as a proxy measure of the pre-phacomorphic state in the eye with phacomorphic glaucoma as majority of them first presented to our center during the phacomorphic attack without prior measurements of the pre-phacomorphic ACD or lens thickness; therefore, their anterior chamber depth would not be representative of their pre-phacomorphic state. Axial length of 23.7 mm was selected as a cut-off for dichotomized logistic regression based on the local population mean from published demographic data. Results: The mean age was 73.1 ± 10.2 years. All phacomorphic and control eyes were ethnic Chinese. The mean presenting intraocular pressures were 49.5 ± 11.8 mmHg and 16.7 ± 1.7 mmHg in the phacomorphic and control eyes respectively (P< 0.0001), whilst the median Snellen best corrected visual acuity were light perception and hand movement in the phacomorphic and control eyes respectively. Eyes with phacomorphic glaucoma had shorter axial length of 23.1 ± 0.9 mm median when compared with that of control eyes, 23.7 ± 1.5 mm (P = 0.0006). Eyes with AL ≤ 23.7 mm were 4.3 times as likely to develop phacomorphic glaucoma when compared with AL > 23.7 mm (P = 0.003). Conclusion: Axial length less than ≤ 23.7 mm was a risk factor for developing phacomorphic glaucoma. Eyes with AL shorter than the population mean were 4.3 times as likely to develop phacomorphic glaucoma compared with eyes with longer than average AL. In an area where phacomorphic glaucoma is prevalent and medical resources are limited, patients with AL shorter than their population mean may be considered for earlier elective cataract extraction as a preventive measure.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/anatomia & histologia , Câmara Anterior/cirurgia , Estudos de Casos e Controles , Catarata/epidemiologia , Extração de Catarata/efeitos adversos , Extração de Catarata/estatística & dados numéricos , Glaucoma/epidemiologia , Humanos , Pressão Intraocular , Complicações Pós-Operatórias/epidemiologia , Prevalência , Estudos Retrospectivos , Fatores de Risco
2.
Indian J Ophthalmol ; 2002 Sep; 50(3): 197-200
Artigo em Inglês | IMSEAR | ID: sea-69924

RESUMO

PURPOSE: To study the safety and efficacy of intracameral lidocaine as anaesthesia in trabeculectomy for primary open-angle glaucoma. METHODS: Trabeculectomy under intracameral anaesthesia using 1% preservative-free lidocaine was performed in 10 patients with primary open-angle glaucoma. Intraoperative pain score, postoperative intraocular pressure (IOP) and endothelial cell count at 3 months were recorded. RESULTS: The mean pain score was 1.70 +/- 1.34. The mean IOP was lowered from 24.60 +/- 8.28 mmHg preoperatively to 14.1 +/- 3.11 mm Hg postoperatively. There was no significant decrease in the mean endothelial cell count 3 months after the surgery (P = 0.375). CONCLUSION: Intracameral lidocaine may be a safe and effective alternative anaesthesia method in trabeculectomy for uncomplicated primary open-angle glaucoma.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Anestesia Local/métodos , Anestésicos Locais/administração & dosagem , Câmara Anterior/cirurgia , Avaliação de Medicamentos , Feminino , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular , Período Intraoperatório , Lidocaína/administração & dosagem , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Prospectivos , Segurança , Trabeculectomia , Resultado do Tratamento , Acuidade Visual
3.
Indian J Ophthalmol ; 2002 Jun; 50(2): 131-2
Artigo em Inglês | IMSEAR | ID: sea-71784

RESUMO

Argon laser suture lysis using the Ritch lens provides a safe and effective means for correction of post--ECCE suture--induced astigmatism.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Extração de Catarata , Feminino , Humanos , Terapia a Laser/métodos , Lentes , Período Pós-Operatório , Segurança , Técnicas de Sutura , Resultado do Tratamento , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA