1.
Med. infant ; 21(3): 244-247, Sept.2014. tab
Artigo em Espanhol | LILACS | ID: biblio-914445

RESUMO

La mejor estrategia en el post-quirúrgico de cardiopatías congénitas para promover la extubación precoz y destete de asistencia respiratoria mecánica (ARM) con ventilación no invasiva (VNI) todavía no ha sido establecida. El objetivo es comparar eficacia de la presión positiva continua en la vía aérea (CPAP) vs presión positiva con dos niveles en la vía aérea (BIPAP) en la extubación electiva de estos pacientes. Es un estudio prospectivo entre el 1 de junio de 2008 y 31 marzo de 2010. Se randomizaron los pacientes para extubación electiva: modo CPAP o BIPAP. Se registraron datos demográficos y del procedimiento quirúrgico, entre otros. El fracaso de VNI fue definido como reintubación dentro de las 72 hs posteriores a la extubación o más de un criterio de intubación. Durante el periodo de estudio 1438 pacientes fueron admitidos en UCI35. En el grupo BIPAP se randomizaron 53 pacientes, de los cuales se extubaron exitosamente 49 (92%), pero 4 se reintubaron debido a falla cardiaca. En el grupo CPAP se randomizaron 46 y fallaron en la extubación 18 (39%) debido a múltiples episodios de desaturación y apneas. De éstos, 11 requirieron reintubación endotraqueal y ARM. En 7 pacientes, se pasó a modo BIPAP y permanecieron extubados, aunque el cruzamiento no fue parte del diseño de este estudio. En el destete de ARM de los pacientes post-quirúrgicos de cardiopatías congénitas, el uso de BIPAP fue más efectivo que CPAP. En esta última modalidad se presentaron mayor número de fracasos de VNI (AU)


The best strategy for early extubation and weaning from mechanical respiration (MV) with non-invasive ventilation (NIV) in post-surgical congenital heart defect patients has not been established yet. The aim of this study was to compare the efficacy of continuous positive airway pressure CPAP) vs bi-level positive airway pressure (BIPAP) in the elective extubation of these patients. A prospective study was conducted between June 1, 2008 and March 31, 2010. Patients that were candidates for elective extubation were randomized to CPAP or BIPAP. Data on demographics and surgical procedure, among others, were recorded. Failure of NIV was defined as the need for reintubation within 72 hours after extubation or more than one criterion for intubation. Over the study period, 1438 patients were admitted to ICU 35. Fifty-three patients were randomized to BIPAP, of whom 49 (92%) were successfully extubated; however, four were reintubated due to heart failure. Forty-six patients were randomized to CPAP. Extubation failed in 18 (39%) due to multiple episodes of desaturation and apneas. Eleven of 18 required endotracheal reintubation and mechanical ventilation. Seven patients were switched to BIPAP and remained extubated, although the switch was not part of the study design. In the weaning of post-surgical congenital heart defect patients from MV, BIPAP was more effective than CPAP. In the latter modality, the incidence of NIV failure was higher (AU)


Assuntos
Humanos , Recém-Nascido , Lactente , Desmame do Respirador/métodos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Extubação/métodos , Ventilação não Invasiva/estatística & dados numéricos , Cardiopatias Congênitas/cirurgia , Período Pós-Operatório , Unidades de Terapia Intensiva Pediátrica , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA