Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Ciênc. rural ; 45(5): 858-866, 05/2015. graf
Artigo em Inglês | LILACS | ID: lil-745830

RESUMO

Brachiaria (signalgrass) is now the most widely used tropical grass genus in Central and South America. However, Brachiaria spp. can cause hepatogenous photosensitization in livestock. Steroidal saponins, specifically protodioscin, present in Brachiaria spp. may be responsible for liver injury and subsequent photosensitization. The objective of this study was to determine the effect of ensiling Brachiaria decumbens and Brachiaria brizantha or making hay from Brachiaria decumbens on the concentrations of steroidal saponin in these grasses. Brachiaria grass had no detectable levels of the saponin protodioscin after 24 days of ensiling. In addition, in Brachiaria decumbens, the concentration of the protodioscin decreased 48% over the first three days after haymaking and then remained constant. These results suggest that livestock consuming Brachiaria either as silage or hay may have reduced risk of intoxication by protodioscin. .


Brachiaria atualmente é o gênero de gramínea tropical mais amplamente utilizado na América Central e do Sul. Entretanto, as espécies de Brachiaria podem causar fotossensibilização hepatógena em animais de produção. Saponinas esteroides, especificamente protodioscina, presentes em Brachiaria, podem ser responsáveis pelo dano hepático e consequentemente fotossensibilização. O objetivo deste estudo foi determinar o efeito da ensilagem de Brachiaria decumbens e Brachiaria brizantha e fenação de Brachiaria decumbens sobre a concentração de saponina esteroide. As amostras de Brachiaria ensiladas não tiveram concentrações detectáveis de saponina protodioscina depois de 24 dias de ensilagem. Assim como em Brachiaria decumbens, a concentração de protodioscina reduziu 48% nos três primeiros dias após a fenação e posteriormente manteve-se constante. Estes resultados sugerem que animais de produção, ao consumirem Brachiaria tanto como silagem ou feno, podem ter o risco de intoxicação por protodioscina reduzido.

2.
Acta cir. bras ; 25(4): 337-341, July-Aug. 2010. ilus
Artigo em Inglês | LILACS | ID: lil-553240

RESUMO

PURPOSE: To verify if the composit poli (2-hydroxyethyl methacrylate)-PolyHEMA/polypropylene mesh implanted in the female rat's abdominal wall could be suitable for the prevention of peritoneal adhesions, and for the evaluation of the tecidual response produced by this biomaterial. METHODS: Polypropylene meshes (Group PP, n=20) and polypropylene meshes coated with a layer of poli (2-hydroxyethyl methacrylate)-PolyHEMA (Group PH, n=20) were implanted on the abdominal wall of Wistar female rats. Ten animals from each group were submitted to euthanasia at 15 and 30 days of the postoperative period. RESULTS: The animals from the group PP presented visceral adhesions on the mesh surface, which was not observed in the ones from group PH. At the histopathological examination foreign body response was observed in both groups, whilst there was a greater intensity of inflammatory response in group PH on both moments. CONCLUSION: The poli (2-hydroxyethyl methacrylate) polyHEMA hydrogel associated to polypropylene mesh reduces visceral adhesion formation in rats, although it may be associated to greater inflammatory reaction.


OBJETIVO: Verificar se compósito poli 2-hidroxietil dimetacrilato (PoliHEMA) / tela de polipropileno implantado na parede abdominal de ratas seria adequado para prevenção de aderências peritoneais e avaliar a resposta tecidual desencadeada por este biomaterial. MÉTODOS: Foram implantadas telas de polipropileno - Grupo PP (n=20) e telas de polipropileno revestidas por uma camada de poli 2 (hidroxietil dimetacrilato)-PolyHEMA - Grupo PH (n=20) na parede abdominal de ratas da linhagem Wistar. Dez animais de cada grupo foram submetidos à eutanásia aos 15 e 30 dias de pós-operatório. RESULTADOS: Os animais do grupo PP apresentaram aderências viscerais na superfície da tela, o que não foi observado nos do grupo PH. Observou-se no exame histopatológico resposta tipo corpo estranho nos dois grupos sendo que no grupo PH houve maior intensidade de resposta inflamatória nos dois momentos. CONCLUSÃO: O hidrogel de poliHEMA quando associado à tela de polipropileno reduz a formação de aderências viscerais em ratos, embora possa estar associado à reação inflamatória mais intensa.


Assuntos
Animais , Feminino , Ratos , Parede Abdominal/cirurgia , Implantes Experimentais , Doenças Peritoneais/prevenção & controle , Peritônio/efeitos dos fármacos , Polipropilenos/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Parede Abdominal/patologia , Materiais Biocompatíveis , Reação a Corpo Estranho/etiologia , Reação a Corpo Estranho/patologia , Inflamação/patologia , Doenças Peritoneais/etiologia , Peritônio/patologia , Poli-Hidroxietil Metacrilato/efeitos adversos , Ratos Wistar , Técnicas de Sutura , Aderências Teciduais/patologia , Aderências Teciduais/prevenção & controle
3.
Acta cir. bras ; 22(1): 8-11, Jan.-Feb. 2007. ilus
Artigo em Inglês | LILACS | ID: lil-440725

RESUMO

PURPOSE: To verify whether pediculated diaphragmatic flaps were suitable to correct iatrogenic wounds in dog's esophagus injuries. METHODS: Seven dogs were submitted to resection of a segment of the esophagical wall, which was then corrected by suturing a pediculated diaphragm flap. Endoscopic evaluation of the esophagical wall was done forty days after the surgical procedure. RESULTS: Three animals died, one due to implant ischemia, caused by strangulation of the phrenic artery; other due to wound infection; and the last, due to mediastinitis. Scar retraction was observed, however, there was no stenosis, allowing the passage of a 9,8 mm probe with no difficulty. The limits between the implants and the native esophagus were indistinguishable, and the implant was covered by esophageal mucosa. CONCLUSION: The diaphragmatic flaps are suitable on the restoring of continuity in dog's thoracic esophagus.


OBJETIVO: Verificar se retalhos diafragmáticos pediculados seriam adequados para correção de defeitos iatrogênicos do esôfago do cão. MÉTODOS: Sete cães foram submetidos à ressecção de um segmento da parede esofágica, o qual foi corrigido por meio da sutura de um pedículo diafragmático pediculado. Um animal morreu devido à isquemia do implante causada pelo estrangulamento da artéria frênica, outro devido à infecção da ferida cutânea e outro devido a mediastinite. Aos 40 dias após o procedimento fez-se um exame endoscópico dos animais nos cães sobreviventes. RESULTADOS: Observou-se retração cicatricial sem repercutir em estenose, permitindo a passagem de sonda de 9,8 mm, sem dificuldade. Os limites entre os implantes e o esôfago nativo se apresentaram indistinguíveis e o implante estava recoberto por mucosa esofágica. CONCLUSÃO: Os retalhos diafragmáticos são adequados na restauração da continuidade do esôfago torácico do cão.


Assuntos
Animais , Cães , Diafragma/transplante , Esofagoplastia/veterinária , Retalhos Cirúrgicos/veterinária , Endoscopia , Estenose Esofágica/diagnóstico , Estenose Esofágica/veterinária , Esofagoplastia/efeitos adversos , Cicatrização
4.
Acta cir. bras ; 20(4): 305-310, July-Aug. 2005. ilus
Artigo em Português | LILACS | ID: lil-414201

RESUMO

OBJETIVO: Comparar o implante de membrana de látex da seringueira sem e com polilisina 0,1 por cento e tela de marlex na reparacão de defeitos abdominais iatrogênicos em ratos. MÉTODOS: Ressectou-se em bloco um segmento circular de aproximadamente três centímetros de diâmetro da parede muscular abdominal ventral de 31 ratos Wistar, preservando-se a pele. Os animais foram divididos em 3 grupos: grupo látex sem polilisina, grupo látex com polilisina 0,1 por cento e grupo marlex. Os animais foram sacrificados aos cinco e aos 120 dias após o procedimento cirúrgico. Fragmentos da parede abdominal foram coletados e submetidos à avaliacão histopatológica. RESULTADOS: As principais alteracões observadas nos grupos tratados com as membranas de látex sem e com polilisina 0,1 por cento foram deiscência (21 animais) e evisceracão (dois animais). A eliminacão dos implantes nos grupos tratados com látex ocorreu, em média, aos 13,8 dias. Nestes animais ocorreu a formacão de tecido conjuntivo fibroso, similar ao observado no grupo que recebeu o marlex. Outras alteracões notadas foram aderências viscero-parietais em todos os grupos avaliados. CONCLUSAO: A membrana de látex da seringueira com e sem polilisina a 0,1 por cento, quando utilizada para reconstrucão de defeitos abdominais em ratos é eliminada, em média, aos 13,8 dias após a sua implantacão, deixando uma base fibrosa de reparacão, similar à observada após a implantacão da tela de marlex.


Assuntos
Ratos , Animais , Masculino , Parede Abdominal/patologia , Hevea , Látex , Polilisina/farmacologia , Polipropilenos/farmacologia , Telas Cirúrgicas , Parede Abdominal/cirurgia , Doença Iatrogênica , Próteses e Implantes , Ratos Wistar , Procedimentos de Cirurgia Plástica , Fatores de Tempo , Cicatrização/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA