Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Radiology ; (12): 1009-1012, 2014.
Artigo em Chinês | WPRIM | ID: wpr-469614

RESUMO

Objective To investigate the effect of inversion time (TI) on flow-sensitive alternating inversion recovery (FAIR) perfusion imaging of spinal bone marrow (SBM),and evaluate the reproducibility of blood flow (BF) measurements using this technique.Methods Twenty four healthy volunteers without lumbar and other disease with clinical and MR studies were prospectively included.The first 14 healthy volunteers were included to study the effect of TI on ASL perfusion imaging of SBM to get the optimized TI,the remaining 10 volunteers were included to investigate the reproducibility of the SBM arterial spin labeling (ASL) scan protocol.The optimized TI of FAIR spinal bone marrow perfusion experiment was carried out on 14 healthy volunteers on 3.0 T magnet,two adjacent vertebral bodies were orderly selected from each volunteer to measure the △M and the SNR of FAIR perfusion MRI with 5 different TIs (800,1 000,1 200,1 400,1 600 ms),and the vertebral bodies selected order were determined by the order of the subjects enrolled.In addition,FAIR perfusion spinal vertebral BF measurements were repeated in last l0 healthy subjects on L4 or L5 by reposition immediately,paired t test and reproducibility statistics (included within-patient standard deviation (wSD) and within-patient coefficient of variation (WCV)) were used to analyze the test-retest experiment reproducibility.Result TI optimization experiments total included 28 vertebral bodies,when TI (ms) was chose as 800,1 000,1 200,1 400,1 600,ms respectively,the mean △M of spinal bone marrow were 20.8±9.0,29.0± 10.9,36.4± 12.5,26.2± 10.2 and 23.8± 11.5,and the mean SNR were 2.0± 1.0,2.3±0.8,2.4± 1.0,2.3±0.8 and 2.0±0.7.With TI increasing,AM and SNR increased first and then decrcascd,the maximum values of both were achieved when the TI near 1 200 ms.Test-retestexperimcnt were carried on 10 vertebral bodies eventually,and two measurements of spinal vertebral BF perfusion before and after were (108.9±4.6)and (109.2 ±4.6)ml · 100g-1· min 1,respectively,and no significant difference was found (t=-0.157,P=0.879),wCV of the measurements was 3.28% (3.57/109.06).Conclusion The optimal TI was 1 200 ms for spinal bone marrow ASL perfusion image,at which the maximum AM,higher SNR,and good reproducibility for the FAIR spinal bone marrow perfusion imaging can be achieved.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA