Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Braz. j. oral sci ; 13(3): 187-192, Jul-Sep/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-725354

RESUMO

AIM: This study evaluated saliva effects on enamel morphology surface after microabrasion technique. METHODS: Enamel blocks (16 mm2) obtained from bovine incisors were divided into 9 groups as follows: one control group (no treatment), four groups with microabrasion treatment using 35% phosphoric acid and pumice (H3PO4+Pum) and other four groups treated with 6.6% hydrochloric acid and silica (HCl+Sil). One group of each treatment was submitted to 4 frames of saliva exposure: without exposure, 1-h exposure, 24-h exposure, and 7-days exposure on in situ regimen. Nineteen volunteers (n=19), considered as statistical blocks, used an intraoral appliance containing the specimens, for 7 days. Enamel roughness (Ra) was tested before and after treatment, and after saliva exposure. Confocal laser scanning microscopy (CLSM) was used to evaluate qualitatively the enamel morphology. RESULTS: All groups exhibited increased Ra after microabrasion. With regards to saliva exposure, the treatment with HCl+Sil presented more susceptibility to the saliva action, but no period of time was efficient in re-establishing this characteristic compared with the control group. CLSM analysis showed reduction of the micro-abrasive damages during the experimental times. CONCLUSIONS: Seven days of saliva exposure were not sufficient for the treated enamel to reach its normal characteristics compared with the control group...


Assuntos
Humanos , Masculino , Feminino , Esmalte Dentário , Microabrasão do Esmalte , Saliva
2.
Artigo em Inglês | IMSEAR | ID: sea-154570

RESUMO

Description of the Technique: The microabrasion technique of enamel consists of selectively abrading the discolored areas or causing superficial structural changes in a selective way. Objective: In microabrasion technique, abrasive products associated with acids are used, and the evaluation of enamel roughness after this treatment, as well as surface polishing, is necessary. This in-vitro study evaluated the enamel roughness after microabrasion, followed by different polishing techniques. Settings and Design: Roughness analyses were performed before microabrasion (L1), after microabrasion (L2), and after polishing (L3).Thus, 60 bovine incisive teeth divided into two groups were selected (n=30): G1- 37% phosphoric acid (37%) (Dentsply) and pumice; G2- hydrochloric acid (6.6%) associated with silicon carbide (Opalustre – Ultradent). Thereafter, the groups were divided into three sub-groups (n=10), according to the system of polishing: A – Fine and superfine granulation aluminum oxide discs (SofLex 3M); B – Diamond Paste (FGM) associated with felt discs (FGM); C – Silicone tips (Enhance - Dentsply). A PROC MIXED procedure was applied after data exploratory analysis, as well as the Tukey-Kramer test (5%). Results: No statistical differences were found between G1 and G2 groups. L2 differed statistically from L1 and showed superior amounts of roughness. Differences in the amounts of post-polishing roughness for specific groups (1A, 2B, and 1C) arose, which demonstrated less roughness in L3 and differed statistically from L2 in the polishing system. Conclusion: All products increased enamel roughness, and the effectiveness of the polishing systems was dependent upon the abrasive used.


Assuntos
Esmalte Dentário/lesões , Polimento Dentário/efeitos adversos , Microabrasão do Esmalte/efeitos adversos
3.
Rev. dental press estét ; 9(4): 72-79, out. -dez.2012. ilus
Artigo em Português | LILACS, BBO | ID: biblio-857651

RESUMO

O desgaste irregular dos dentes, especialmente dos anteriores, além de uma diversidade de formatos anatômicos, pode acarretar em desarranjos estéticos do sorriso. Dessa forma, o contorno cosmético é um procedimento estético que implica em desgaste irreversível da estrutura dentária com pontas diamantadas e discos de acabamento, visando corrigir os parâmetros de estética e reflexão da luz dos dentes anteriores e pré-molares. Nesse sentido, todos os passos para a realização do contorno cosmético são críticos e de extrema importância. O objetivo desse artigo é apresentar, através do relato de um caso clínico, a confecção de uma remodelação cosmética do sorriso guiada por princípios de ilusão de óptica baseados em mínimos desgastes em esmalte dentário, garantindo uma previsibilidade estética do sorriso


Irregular dental wear, especially from the anterior teeth, and the various anatomic shapes can lead to an esthetic breakdown of the smile. So, cosmetic contouring is an esthetic approach which implies irreversible dental abrasion by diamond burs and fnishing disks in order to correct the esthetic parameters and light reflection of anterior teeth and pre-molars. In this sense, all steps for the cosmetic contouring procedure are critical and very important. The aim of this work was to present a case report that shows the cosmetic smile remodeling guided by principles of optical illusion based on minimal dental abrasion, ensuring a predictable esthetic smile.


Assuntos
Humanos , Feminino , Adulto Jovem , Técnicas Cosméticas , Estética Dentária , Desgaste dos Dentes
4.
Braz. j. oral sci ; 10(3): 189-192, Jul.-Sep. 2011. tab
Artigo em Inglês | LILACS, BBO | ID: lil-725240

RESUMO

Aim: To evaluate the influence of light-curing units and light-curing time on the microhardness of a nanofilled composite resin. Methods: Forty-five composite resin (Z350 - 3M) specimens were randomly prepared using Teflon ring molds (4.0 mm internal diameter and 2 mm depth) and divided into nine experimental groups (n=5): three polymerization units (conventional - 450 mW/ cm2; 2nd generation LED - 1100 mW/cm2; and 3rd generation LED - 700 mW/cm2) and three lightcuring times (20 s, 40 s, and 60 s). All specimens were polymerized with the light-curing tip positioned 8 mm far from the top surface of the specimen. After 24 h, Knoop microhardness measurements were made on the top and bottom surfaces of the specimen, with a load of 10 g for 10 s. Five indentations were made on each surface. All results were analyzed statistically by subdivided parcel ANOVA (Split-Plot) and Tukey's tests (p<0.05). Results: There were no statistically significant differences for the polymerization unit and light-curing time factors in either top or bottom surface. For all experimental conditions, the top surfaces showed greater hardness than the bottom surfaces (p<0.0001). Conclusions: The mode of polymerization and the lightcuring time did not affect the hardness of the nanofilled composite resin, and increasing the lightcuring time did not improve the hardness of the bottom surface of the composite resin.


Assuntos
Resinas Compostas , Polimerização , Dureza
5.
Braz. oral res ; 25(2): 168-173, Mar.-Apr. 2011. tab
Artigo em Inglês | LILACS | ID: lil-583852

RESUMO

The aim of this in vitro study was to evaluate the effect of different mouthwashes on superficial roughness and Knoop hardness of two resin composites. Eighty specimens (6 mm Ø and 2 mm height) were prepared and divided into eight experimental groups (n = 10) according to the resin composites (4 Seasons and Esthet X), and storage solutions (G1 - Distilled water; G2 - Colgate Plax Overnight; G3 - Colgate Plax Alcohol Free; and G4 - Colgate Plax Whitening). The initial hardness and roughness readings (T1) were measured and then the specimens were stored in 2 mL of mouthwash for 12 h (T2) and 24 h (T3). The data were analyzed with repeat-measures two-way ANOVA and Tukey's test (α = 5 percent). Regardless of the type of solution and time of exposure, there was no statistical difference for roughness between the resins (p = 0.44). G4 and G8 presented higher roughness means than G1, G3, G5 and G7, after 12 and 24 hours of immersion. For Knoop microhardness analysis, there was a significant reduction for all groups after 12 hours and 24 hours. We conclude that the mouthwashes containing hydrogen peroxide and/or alcohol decrease the microhardness of the resins tested; however, the mouthwash containing hydrogen peroxide had a higher deleterious effect on roughness.


Assuntos
Humanos , Resinas Compostas/química , Antissépticos Bucais/farmacologia , Análise de Variância , Testes de Dureza , Peróxido de Hidrogênio/química , Imersão , Teste de Materiais , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo
6.
Rev. dental press estét ; 7(4): 42-51, out.-dez. 2010. ilus
Artigo em Português | LILACS, BBO | ID: lil-578148

RESUMO

O protocolo restaurador direto com resina composta para dentes anteriores fraturados é um desafio na Odontologia Adesiva atual, já que existem vários compósitos à disposição no mercado, com características ópticas e mecânicas cada vez mais semelhantes às da estrutura dentária. Dessa forma, a técnica de estratificação em camadas de resina composta torna-se eficiente para uso na clínica odontológica. Nesse artigo, o caso clínico apresentado abordará a restauração estética de um incisivo medial fraturado, com o procedimento de estratificação de resina composta, trabalhando os conceitos de translucidez e opacidade para uma adequada reabilitação dentária de forma estética e funcional.


Assuntos
Humanos , Masculino , Adulto Jovem , Resinas Compostas , Estética Dentária , Incisivo , Esmalte Dentário , Polimento Dentário , Dentina , Sorriso
7.
Braz. oral res ; 22(2): 106-111, 2008. ilus, tab
Artigo em Inglês | LILACS | ID: lil-485948

RESUMO

This in vitro study evaluated the effectiveness of whitening dentifrices for the removal of extrinsic tooth stains. Twenty dental blocks (4 x 4 mm), including enamel and dentine, removed from freshly extracted bovine incisors, were randomly divided into 4 groups: G1 - distilled water, G2 - Colgate, G3 - Crest Extra Whitening and G4 - Rapid White. In all specimens, the dentin was covered with colorless nail polish, and the enamel was left exposed. Next, the specimens were immersed in a solution of black tea, which was changed every 24 h, for a period of 6 days. After this period, a photo-reflectance reading was taken (Time 1) with a spectrometer. The stained specimens were then submitted to linear brushing movements (5,000 cycles) using brushes (Oral B-Soft) coupled to an automatic toothbrushing machine, under a static axial load of 200 g and with a speed of 4 movements/second, at 37°C, with the dentifrice or water being injected every 60 s. When toothbrushing ended, a second photo-reflectance reading was taken (Time 2). The results were submitted to two-criteria analysis of variance (ANOVA) and to the Tukey test ( = 0.05). When the two times for a same group were compared, Time 2 presented the highest reflectance values with statistical difference only for G3 and G4. Among the dentifrices tested, only the Rapid White group differed from the control group, presenting the highest reflectance values. Only the whitening dentifrice Rapid White was effective for the removal of extrinsic stains.


Assuntos
Animais , Bovinos , Dentifrícios/uso terapêutico , Clareamento Dental/métodos , Descoloração de Dente/terapia , Escovação Dentária/métodos , Análise de Variância , Colorimetria , Avaliação Pré-Clínica de Medicamentos , Esmalte Dentário/efeitos dos fármacos , Dentifrícios/química , Distribuição Aleatória , Espectrofotometria , Dióxido de Silício/uso terapêutico , Fluoreto de Sódio/uso terapêutico , Escovação Dentária/instrumentação
8.
Braz. j. oral sci ; 6(21): 1313-1319, Apr.-June 2007. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-850532

RESUMO

This study analyzed the esthetics components of the smile, evaluating the relationship between the curve formed by the incisal line of the anterior superior teeth and the curve of the inferior lip, the touch of this incisal line on the inferior lip, the teeth displayed during smile, the relationship between the facial midline with the arch midline, the location of the arch midline and gender differences. Eighty-eight undergraduate students of the dentistry course of the TiradentesUniversity were selected. Two photographs were taken (smiling face and smile) using digital camera. The statistical analysis was performed after image tracing evaluation. Results show that the coincidence of the facial midline with the arch midline occurred only on half of the students. Most of the students presented parallelism between the incisal plan and the interpupillary line. Smiles with or without touch of the incisal line on the lower lip, smiles revealing up to the seconds premolars or firsts molars, and parallel or straight smiles were also most commonly observed. The majority of the men presented centeredmidline arch while women presented deviation to the right. No difference was found between the distribution of the arch midline.


Assuntos
Adolescente , Adulto , Humanos , Masculino , Feminino , Arco Dental , Oclusão Dentária , Estética Dentária , Sorriso
9.
J. appl. oral sci ; 15(2): 105-109, Mar.-Apr. 2007. tab
Artigo em Inglês | LILACS | ID: lil-452765

RESUMO

The aim of this in vitro study was to evaluate the susceptibility of a hybrid composite resin (Filtek Z250 - 3M ESPE) to staining, when light cured in four different modes and immersed in two different media. Composite resin specimens were randomly prepared and polymerized according to the experimental groups (conventional - 550 mW/cm² / 30 seconds; soft start - 300mW/cm² / 10 seconds + 550 mW/cm² / 20 seconds; high intensity - 1060 mW/cm² - 10 seconds; pulse delay - 550 mW/cm² - 1 seconds + 60 seconds of waiting time + 550 mW/cm² - 20 seconds) and immersed in one of two media (distilled water or absolute ethanol) for 24h. Next, the specimens were immersed in a 2 percent methylene blue solution for 12 hours. Afterwards, the specimens were washed and prepared for the spectrophotometric analysis. For statistical analysis, two-way ANOVA (4X2) and Tukey's test were performed on the data at 0.05 confidence level. Soft start showed the least staining, and was statistically different from the high intensity and pulse delay light curing modes (p<0.05). Conventional light curing unit did not show statistically significant differences from any other groups (p>0.05). There were no significant differences between the two immersion media (p>0.05). The soft start polymerization mode showed lower susceptibly of the composite resin to staining than high intensity and pulse delay, irrespective of the immersion medium.

10.
Rev. odonto ciênc ; 21(54): 346-350, out.-dez. 2006. ilus
Artigo em Português | LILACS, BBO | ID: lil-457423

RESUMO

Este estudo analisou a prevalência da proporção áurea de indivíduos com sorrisos agradáveis, e sua diferença entre os sexos. Oitenta e oito estudantes do curso de odontologia da Faculdade Tiradentes foram selecionados, sendo 51 mulheres e 37 homens, entre 18 e 25 anos, obedecendo aos critérios da pesquisa. Foram realizadas as tomadas fotográficas dos dentes, utilizando câmera digital e papel milimetrado. Para a análise dos dados foi selecionado o teste do Qui-quadrado (χ2), utilizando-se o nível de significância de 5%, realizou-se a estatística com o software Bio-Estat 2.0. Os resultados mostraram que homens e mulheres não diferem quanto à presença da proporção áurea entre os incisivos centrais e laterais no lado esquerdo e a proporção áurea no lado direito está mais prevalente em mulheres do que nos homens. Homens e mulheres não apresentam proporção áurea entre os incisivos laterais e caninos no lado direito e a proporção áurea no lado esquerdo está mais prevalente em mulheres do que nos homens. A relação de proporção áurea não é aplicada na maior parte da população.


Assuntos
Humanos , Masculino , Feminino , Adulto , Estética Dentária , Sorriso
11.
Rev. Assoc. Paul. Cir. Dent ; 60(5): 399-402, set.-out. 2006. ilus
Artigo em Português | LILACS, BBO | ID: lil-543823

RESUMO

O mecanismo de ação dos agentes clareadores consiste de uma reação química de oxirredução, que pode ser acelerada por uma fonte de luz ou calor. Apesar do aumento de temperatura favorecer uma reação mais rápida este deve ser limitado, a fim de se evitar danos pulpares irreversíveis. Fontes de energia como laseres e LEDs estão sendo bastante utilizadas objetivando um clareamento seguro e efetivo, desde que utilizados com moderação. A associação dessas duas fontes levou ao desenvolvimento de aparelhos que apresentam duas unidades geradoras de luz, um sistema de luz fria emitida por LEDs e um sistema de luz laser de diodo. Este trabalho relata um caso clínico de clareamento de consultório que teve sua ação potencializada por LEDs associados ou não ao laser de diodo. Ambos os sistemas foram efetivos na ativação do agente clareador. Porém, a mudança de cor do gel clareador ocorreu mais rápida quando a associação LED/laser de diodo foi utilizada.


The action mechanism of bleaching agents consists of a chemical oxireduction reaction, which can be accelerated by a light or heat sources. Although the temperature increase contributes to a faster reaction, this should be limited in order to avoid irreversible pulp damages. Sources of energy like laser and LED's have been used aiming an effective and safe bleaching treatment, once their use is moderated. The association between these two sources provided the development of specific devices with two light unit generators, a system of cold light emitted by LED's and a diode laser system. This work reports an in-office bleaching clinical case which had the action potentiated by the use of LED's associated or not to a diode laser. Both systems were effective in the bleaching agent activation. However, the color change of the whitening gel ocurred faster when LED/diode laser association was used.


Assuntos
Humanos , Masculino , Adulto , Peróxido de Hidrogênio , Lasers , Clareamento Dental
12.
Braz. oral res ; 19(4): 302-306, Oct.-Dec. 2005. tab, graf
Artigo em Inglês | LILACS | ID: lil-421133

RESUMO

A cor do compósito e a polimerização realizada com a ponta do aparelho de fotoativação distante da superfície do compósito são fatores que podem afetar a efetividade de polimerização. Assim, o objetivo deste estudo in vitro foi avaliar a influência desses fatores na microdureza superficial de um compósito híbrido (Z250 – 3M ESPE). Quarenta e cinco espécimes de compósito foram aleatoriamente preparados de acordo com os nove grupos experimentais (n = 5): três distâncias de fotoativação (2 mm, 4 mm e 8 mm) e três cores de compósito (A1, A3,5 e C2). Todas as amostras foram fotoativadas com aparelho de fotoativação ajustado com intensidade contínua de 550 mW/cm2. Após 24 horas, dez medidas de dureza Knoop foram obtidas nas superfícies de topo e fundo de cada amostra, com carga de 25 gramas por um tempo de 10 segundos. Resultados mostraram que, para a superfície de fundo, os grupos com a fotoativação realizada com distância de 2 e 4 mm apresentaram maiores médias do que os grupos com distância de 8 mm, e os grupos de cor A1 apresentaram maiores médias e com diferenças estatísticas que os grupos de cor C2, e o grupo A3,5 não apresentou diferenças estatísticas quando comparado aos outros grupos. Para a superfície de topo, não houve diferenças estatísticas significantes para os fatores estudados. Para todas as condições experimentais, a superfície de fundo apresentou médias de durezas estatisticamente menores do que as da superfície de topo. Pode-se concluir que os fatores cor do compósito e distância de polimerização são importantes fatores a serem considerados para a obtenção de adequada polimerização.


Assuntos
Resinas Compostas/efeitos da radiação , Restauração Dentária Permanente/instrumentação , Luz , Cor , Resinas Compostas/química , Equipamentos Odontológicos , Restauração Dentária Permanente/normas , Dureza/efeitos da radiação , Teste de Materiais , Polímeros , Propriedades de Superfície
13.
Braz. oral res ; 19(1): 30-35, Jan.-Mar. 2005. tab, graf
Artigo em Inglês | LILACS | ID: lil-403731

RESUMO

O objetivo deste estudo in vitro foi avaliar através de espectrofotometria a influência das técnicas de inserção incremental e de fotopolimerização progressiva na microinfiltração de cavidades Classe V. Foram preparadas 40 cavidades cilíndricas na superfície radicular vestibular de incisivos bovinos e preenchidas com resina composta (Z250). Os espécimes foram divididos em quatro grupos: I: a resina foi inserida em camada única e fotopolimerizada por 40 segundos; II: a resina foi inserida em camada única e fotopolimerizada progressivamente com um aparelho "soft-start"; III: a resina foi inserida em duas camadas e fotopolimerizada por 40 segundos; IV: a resina foi inserida em duas camadas e fotopolimerizada progressivamente. Em seguida os espécimes foram submetidos a 3.000 ciclos térmicos a 5 ± 2°C e 55 ± 2°C, preparados, corados com azul de metileno a 2%, seccionados, triturados e avaliados em espectrofotometria para se quantificar o corante infiltrado. Os dados foram submetidos a ANOVA. Os resultados demonstraram as seguintes médias: inserção única e fotopolimerização convencional (I): 0,06075 µg/ml; inserção única e fotopolimerização progressiva (II): 0,04030 µg/ml; inserção incremental e fotopolimerização convencional (III): 0,04648 µg/ml; inserção incremental e fotopolimerização progressiva (IV): 0,04339 µg/ml. Não foram encontradas diferenças estatísticas significativas entre as médias. Observou-se que o aparelho Degulux "soft-start" emite uma intensidade de luz inicial muito alta para promover fotopolimerização progressiva.


Assuntos
Animais , Bovinos , Resinas Compostas , Preparo da Cavidade Dentária/métodos , Infiltração Dentária/terapia , Luz , Tecnologia Odontológica/métodos , Análise de Variância , Polímeros , Espectrofotometria
14.
Braz. oral res ; 18(4): 312-316, Oct.-Dec. 2004. tab
Artigo em Inglês | LILACS | ID: lil-398750

RESUMO

A adequação de dentes bovinos e suínos na substituição de dentes humanos extraídos tem sido avaliada em vários estudos. O objetivo deste estudo in vitro foi analisar o padrão de infiltração marginal em esmaltes humano, bovino e suíno. Cavidades cúbicas (2 x 2 x 2 mm3) foram realizadas em blocos de esmalte obtidos de dentes molares humanos, incisivos bovinos e molares suínos. As cavidades foram restauradas com compósito resinoso fotopolimerizável e cimento de ionômero de vidro. Os espécimes foram submetidos à termociclagem por 1.000 ciclos entre 5 ± 2ºC e 55 ± 2ºC e imersos em azul de metileno a 2%, por 12 horas. A concentração de corante infiltrado foi medida, quantitativamente, através de espectrofotometria. Os dados foram transformados em µg/ml e submetidos à análise estatística ANOVA, seguida pelo teste de Tukey. As médias de infiltração marginal (µg/ml ± DP) nos esmaltes bovino e suíno não foram significativamente diferentes (0,0668 ± 0,0246 vs. 0,0674 ± 0,0286), mas foram superiores e estatisticamente diferentes (p < 0,01) das encontradas no esmalte humano (0,0407 ± 0,0195, p < 0,01), e as médias de infiltração marginal foram superiores nas restaurações realizadas com o cimento de iônomero de vidro (0,0695 ± 0,01313 vs. 0,0471 ± 0,0163, p < 0,01). Os resultados permitiram concluir que os substratos bovino e suíno permitem uma maior infiltração marginal que o esmalte humano, indicando que a capacidade de selamento marginal pode ser afetada por diferenças entre esses substratos. Os resultados indicam que se deve ter prudência na substituição do esmalte humano em estudos laboratoriais de microinfiltração.


Assuntos
Humanos , Animais , Bovinos/anatomia & histologia , Resinas Compostas/farmacologia , Infiltração Dentária , Esmalte Dentário/efeitos dos fármacos , Cimentos de Ionômeros de Vidro/farmacologia , Técnicas In Vitro , Suínos/anatomia & histologia , Análise de Variância , Resinas Compostas/síntese química , Modelos Animais de Doenças , Esmalte Dentário/química , Infiltração Dentária/diagnóstico , Corantes , Cimentos de Ionômeros de Vidro/síntese química , Incisivo/química , Incisivo/efeitos dos fármacos , Dente Molar/química , Dente Molar/efeitos dos fármacos
15.
Braz. oral res ; 18(3): 253-259, jul.-set. 2004. tab, graf
Artigo em Inglês | LILACS | ID: lil-383289

RESUMO

O objetivo deste estudo in vitro foi avaliar quantitativamente a microinfiltração em cavidades classe V restauradas com a utilização de sistemas adesivos de frasco único e autocondicionante com e sem a realização de condicionamento ácido prévio. Dois sistemas adesivos de frasco único, Single Bond e Prime & Bond 2.1, e um sistema adesivo autocondicionante, Clearfil Mega Bond, foram utilizados. Cento e vinte pré-molares humanos hígidos foram divididos em seis grupos, e vinte restaurações classe V foram preparadas na dentina radicular para avaliar cada sistema adesivo. Cada sistema adesivo foi utilizado com e sem condicionamento ácido. Os espécimes foram preparados, corados com azul de metileno a 2%, seccionados, triturados e avaliados em espectrofotometria para quantificar o corante infiltrado. Os dados foram submetidos a ANOVA e ao teste de Tukey-Kramer. Nenhuma diferença estatística significativa foi encontrada entre os sistemas adesivos quando o condicionamento ácido não foi utilizado. No entanto, o sistema adesivo Single Bond demonstrou menores médias de microinfiltração comparadas às médias dos sistemas adesivos Clearfil Mega Bond e Prime & Bond 2.1 quando o condicionamento com ácido fosfórico a 37% foi utilizado. Os sistemas adesivos Single Bond e Clearfil Mega Bond demonstraram o mesmo comportamento quando as recomendações do fabricante foram seguidas.


Assuntos
Humanos , Infiltração Dentária , Colagem Dentária/métodos , Preparo da Cavidade Dentária/métodos , Cimentos de Resina , Análise de Variância , Colagem Dentária/instrumentação , Preparo da Cavidade Dentária/instrumentação , Teste de Materiais , Espectrofotometria
16.
Braz. oral res ; 18(3): 260-265, jul.-set. 2004. ilus, tab
Artigo em Inglês | LILACS | ID: lil-383290

RESUMO

Fatores como o modo de ativação, a técnica restauradora e a configuração cavitária podem afetar a resistência adesiva à dentina. Este estudo avaliou os efeitos dos modos de ativação e das técnicas restauradoras na resistência de união compósito/dentina na parede vestibular de restaurações classe I. O esmalte oclusal dos dentes foi removido para expor uma superfície dentinária planificada. Cavidades oclusais (4 x 3 x 3 mm) foram preparadas em dentina. O adesivo Single Bond foi aplicado de acordo com as instruções do fabricante, e o compósito TPH Spectrum, inserido através de três diferentes técnicas: oblíqua incremental, horizontal incremental ou incremento único. O compósito foi ativado utilizando o método contínuo (600 mW/cm² por 40 s) ou "Soft-Start" (250 mW/cm² por 10 s + 600 mW/cm² por 30 s). O grupo controle foi obtido pela união somente à parede vestibular planificada (fator C = 1). Os dentes foram armazenados por 24 h em água a 37ºC e preparados para o ensaio de microtração (0,5 mm/min). Os espécimes apresentaram na secção transversal uma área de união de aproximadamente 0,8 mm². Os resultados foram analisados pela ANOVA (dois fatores), pelos testes de Tukey e Dunnett (a = 0,05). A técnica incremental seguida da ativação com ambas as formas de fotopolimerização produziu maiores valores de resistência de união que a técnica de incremento único (p < 0,05). A resistência de união sempre foi menor quando a restauração foi confeccionada em cavidade (p < 0,05), exceto quando foram utilizadas ativação com "Soft-Start" e técnicas incrementais. A resistência de união às paredes cavitárias é dependente da técnica de inserção e do modo de ativação da resina composta.


Assuntos
Humanos , Dentina , Colagem Dentária/métodos , Restauração Dentária Permanente/métodos , Cimentos de Resina , Análise de Variância , Preparo da Cavidade Dentária , Resistência à Tração
17.
Rev. ABO nac ; 10(2): 113-117, abr.-maio 2002. ilus, tab
Artigo em Português | LILACS | ID: lil-318536

RESUMO

Este trabalho analisou quantitativamente a suceptibilidade de uma resina composta modificada por poliácido (Variglass) de ter a sua superfície manchada no decorrer do seu envlhecimento artificial. Foram utilizados 40 corpos de prova polidos e divididos em grupos (0, 7, 30 e 60 dias), sendo que apenas os três últimos sofreram ciclagens térmicas. Os corpos de prova foram imersos em soluçäo aquosa de azul de metileno a 2 por cento, lavados, secados e triturados. O pó resultante da trituraçäo de cada corpo de prova foi imerso em álcool absoluto. A soluçäo foi centrifugada e o sobrenadante utilizado para realizar a leitura em aparelho de espectrofotometria. Os resultados foram analisados pelo teste de anova e Tukey-Kramer, onde verificou-se que a amostra do grupo que sofreu maior quantidade de ciclos térmicos (60 dias) foi a que mais impregnou o pigmento; para os grupos intermediários (30 e 7 dias), os resultados mostraram que o grupo de 30 dias pigmentou mais do que o grupo de 7 dias. Neste último, o resultado foi semelhante ao grupo que näo sofreu ciclagem térmica


Assuntos
Compômeros
18.
Rev. ABO nac ; 10(1): 23-29, fev.-mar. 2002. tab
Artigo em Português | LILACS, BBO | ID: lil-312795

RESUMO

A proposta deste estudo foi verificar quantitativamente, por meio de espectrofotometria, a influência de uma soluçäo evidenciadora de placa bacteriana na alteraçäo de cor por deposisäo de corante de dois materiais híbridos de ionômero de vidro/resina composta. Os materiais restauradores utilizados foram: Vitremer, Variglass e a soluçäo de fucsina básica a 0,5 por cento, usada como evidenciador de placa bacteriana. Foram confeccionados noventa corpos de prova que foram divididos em grupos e imersos em soluçäo corante durante 1 minuto. Para determinar a quantidade de corante depositado sobre as amostras, foram obtidas soluçöes com a imersäo dos corpos de prova em álcool absoluto por 48 horas. As soluçöes foram levadas ao aparelho de espectrofotometria para leitura de absorbância, regulado com comprimento de onda igual nanômetros...


Assuntos
Corantes , Resinas Compostas , Placa Dentária , Cimentos de Ionômeros de Vidro , Materiais Restauradores do Canal Radicular
19.
Pesqui. odontol. bras ; 14(4): 351-6, out.-dez. 2000. tab, graf
Artigo em Português | LILACS, BBO | ID: lil-281449

RESUMO

O objetivo deste trabalho, in vitro, foi comparar dois métodos de análise de superfície, a rugosimetria e a espectrofotometria, aplicados a três materiais ionoméricos quando submetidos a diferentes tratamentos superficiais de acabamento e polimento. Para a análise de superfície, 60 corpos-de-prova de cada material (Chelon Fil, Vitremer e Dyract) foram confeccionados e divididos aleatoriamente em 3 grupos experimentais. A superfície dos corpos-de-prova foi avaliada por um rugosímetro, sendo obtida uma média de rugosidade. A análise espectrofotométrica consistiu na quantificaçäo de corante impregnado na superfície do material de acordo com os grupos experimentais. Os corantes utilizados foram a fucsina básica 0,5 por cento e a eritrosina 0,5 por cento. Os dados foram submetidos à análise de variância e teste t de Student em nível de 5 por cento. Os resultados mostraram näo haver correlaçäo linear confiável entre os dois métodos utilizados. Verificou-se que as brocas "carbide" produziram a maior rugosidade para o material Chelon Fil, seguido dos tratamentos com discos Sof-Lex e tira matriz. Para o Vitremer, näo houve diferença entre o acabamento e polimento com discos Sof-Lex e o grupo controle (tira matriz). Os diferentes tratamentos superficiais produziram superfícies semelhantes para o material Dyract. As médias de deposiçäo superficial de corante para Chelon Fil, Vitremer e Dyract foram: 1,7261, 1,4759, 1,3318, respectivamente, considerando p<0,05. No entanto, os materiais comportaram-se de forma semelhante quando diferentes sistemas de acabamento e polimento foram utilizados


Assuntos
Cimentos de Ionômeros de Vidro/análise , Técnicas In Vitro , Pigmentação , Polimento Dentário/métodos , Espectrofotometria
20.
Rev. ABO nac ; 6(2): 85-8, abr.-maio 1998. ilus
Artigo em Português | LILACS, BBO | ID: lil-222597

RESUMO

Nas superfícies oclusais dos dentes, onde os procedimentos preventivos têm demonstrado menor efeito, muitas vezes o tratamento restaurador se faz necessário. O amálgama de prata, os compósitos e os cimentos de ionômero de vidro podem ser indicados para restaurar cavidades oclusais. O surgimento dos híbridos de ionômero/resina possibilitou novas opçöes para restaurar essa superfície. O objetivo deste trabalho é descrever um caso clínico utilizando uma resina ionomérica como alternativa conservadora para restauraçäo de cárie de superfície oclusal


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Cimentos de Ionômeros de Vidro , Oclusão Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA