Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Braz. dent. j ; 25(3): 191-196, 07/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-722152

RESUMO

This study evaluated the antimicrobial activity of a Ricinus communis-based experimental dentifrice for denture hygiene against the following standard strains: Staphylococcus aureus, Escherichia coli, Streptococcus mutans, Enterococcus faecalis, Candida albicans and Candida glabrata. The minimum inhibitory concentration (MIC) assay was performed with R. communis in pure oil at 2.5%. Only E. coli was not inhibited by R. communis, but the MIC (0.0781%) was effective against the other microorganisms. From these results it was determined the R. communis concentrations for experimental dentifrices, 1, 2, 5 and 10%, which were evaluated by the test-well diffusion in agar. The commercial dentifrices Colgate, Trihydral and Corega Brite were tested for comparative purposes. The diameter of the zones of bacterial growth inhibition produced around the wells was measured (in mm) with a rule under reflected light. Data were analyzed statistically by analysis of variance and Tukey's post-hoc test (α=0.05). Neither the commercial nor the experimental dentifrices were effective against E. coli. The experimental dentifrices containing R. communis at 2, 5 and 10% presented action against S. mutans, S. aureaus and E. faecallis. The experimental dentifrices showed no antimicrobial activity against Candida spp. and E. coli in any of the tested concentrations. Trihydral was the most effective. Comparing the experimental dentifrices, the product with 10% R. communis produced the largest zones of bacterial growth inhibition and had similar antimicrobial activity to the commercial dentifrices, except against S. aureus.


Este estudo avaliou a atividade antimicrobiana de um dentifrício experimental a base de Ricinus communis para higiene de prótese contra as seguintes cepas padrão: Staphylococcus aureus, Escherichia coli, Streptococcus mutans, Enterococcus faecalis, Candida albicans e Candida glabrata. O ensaio de concentração inibitória mínima foi realizado com R. communis em óleo puro a 2,5 % . Apenas a E. coli não foi inibida por R. communis, no entanto, a concentração mínima (0,0781%) foi eficaz contra os outros microrganismos. A partir destes resultados foram determinadas as concentrações dos dentifrícios experimentais: 1, 2, 5 e 10 %, as quais foram avaliadas pelo teste de difusão em Agar. Os dentifrícios comerciais Colgate, Trihydral e Corega Brite foram testados para fins comparativos. O diâmetro dos halos de inibição do crescimento bacteriano, em torno dos poços, foi medido (em mm) com uma régua sob uma luz refletida. Os dados foram analisados estatisticamente por meio de análise de variância e teste post-hoc de Tukey (α=0,05). Nem os dentifrícios comerciais nem os experimentais foram eficazes contra E. coli. Os dentifrícios experimentais contendo R. communis a 2 , 5 e 10 % apresentaram ação contra S. mutans, S. aureaus e E. faecallis. Os dentifrícios experimentais não mostraram atividade antimicrobiana contra Candida spp e E. coli em nenhuma das concentrações testadas . O Trihydral foi o mais eficaz. Comparando os dentifrícios experimentais, o produto com 10% de R. communis produziu os maiores halos de inibição do crescimento microbiano e apresentou atividade antimicrobiana.


Assuntos
Anti-Infecciosos/farmacologia , Dentifrícios , Extratos Vegetais/farmacologia , Ricinus/química , Técnicas In Vitro , Testes de Sensibilidade Microbiana
2.
Braz. dent. j ; 23(4): 387-393, 2012. tab
Artigo em Inglês | LILACS | ID: lil-658015

RESUMO

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.


Desinfetantes químicos são normalmente associados a métodos mecânicos para remover manchas e reduzir a formação do biofilme. Este estudo avaliou o efeito de desinfetantes na liberação de íons metálicos e na rugosidade superficial do titânio comercialmente puro, ligas metálicas e resina acrílica termopolimerizável, simulando 180 ensaios de imersões. Espécimes em formato de discos foram confeccionados com titânio comercialmente puro (Tritan), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Os espécimes (n=5) foram imersos nestas soluções: hipoclorito de sódio a 0,05%, Periogard, Cepacol, Corega Tabs, Medical Interporous e Polident. Como controle, foi utilizada a água deionizada. A análise quantitativa de liberação de íons metálicos foi realizada por meio de espectrometria de massa com plasma indutivamente acoplado (ELAN DRC II). O rugosímetro (Surftest SJ-201P) foi utilizado para medir a rugosidade superficial (µm). Os dados foram registrados antes e depois das imersões e avaliados por ANOVA com dois fatores e teste de Tukey (α=0,05). A liberação de níquel provou ser mais expressiva nas ligas Vi-Star e Fit Cast-V após a imersão em Medical Interporous. Houve diferença significante na rugosidade superficial da resina (p=0,011) após a imersão. O Cepacol causou maior rugosidade superficial de forma significativa. Os produtos de imersão não influenciaram nos resultados da rugosidade do metal (p=0,388). Pode-se concluir que as ligas metálicas testadas podem ser consideradas seguras para a fabricação de próteses removíveis, mas as soluções desinfetantes como o Cepacol e a pastilha Medical Interporous para a imersão diária da prótese devem ser utilizados com cautela, pois causaram maior rugosidade superficial da resina e maior liberação de íons, respectivamente.


Assuntos
Humanos , Bases de Dentadura , Ligas Dentárias/química , Higienizadores de Dentadura/química , Resinas Acrílicas/química , Ligas/química , Alumínio/análise , Berílio/análise , Boratos/química , Cetilpiridínio/química , Clorexidina/análogos & derivados , Clorexidina/química , Ligas de Cromo/química , Cromo/análise , Ácido Cítrico/química , Desinfetantes de Equipamento Odontológico/química , Materiais Dentários/química , Teste de Materiais , Metais/análise , Metais/química , Molibdênio/análise , Níquel/análise , Espectrofotometria Atômica , Propriedades de Superfície , Hipoclorito de Sódio/química , Sulfatos/química , Titânio/análise , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA