1.
Zhongguo Yi Liao Qi Xie Za Zhi ; (6): 248-253, 2022.
Artigo em Chinês | WPRIM | ID: wpr-928898

RESUMO

To solve the problem of real-time detection and removal of EEG signal noise in anesthesia depth monitoring, we proposed an adaptive EEG signal noise detection and removal method. This method uses discrete wavelet transform to extract the low-frequency energy and high-frequency energy of a segment of EEG signals, and sets two sets of thresholds for the low-frequency band and high-frequency band of the EEG signal. These two sets of thresholds can be updated adaptively according to the energy situation of the most recent EEG signal. Finally, we judge the level of signal interference according to the range of low-frequency energy and high-frequency energy, and perform corresponding denoising processing. The results show that the method can more accurately detect and remove the noise interference in the EEG signal, and improve the stability of the calculated characteristic parameters.


Assuntos
Algoritmos , Eletroencefalografia , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Análise de Ondaletas
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; (6): 278-282, 2022.
Artigo em Chinês | WPRIM | ID: wpr-928904

RESUMO

Mercury sphygmomanometer based on traditional auscultation method is widely used in primary medical institutions in China, but a large amount of blood pressure data can not be directly recorded and applied in scientific research analysis, meanwhile auscultation data is the clinical standard to verify the accuracy of non-invasive electronic sphygmomanometer. Focusing on this, we designed a miniature non-invasive blood pressure measurement and verification system, which can assist doctors to record blood pressure data automatically during the process of auscultation. Through the data playback function,the software of this system can evaluate and verify the blood pressure algorithm of oscillographic method, and then continuously modify the algorithm to improve the measurement accuracy. This study introduces the hardware selection and software design process in detail. The test results show that the system meets the requirements of relevant standards and has a good application prospect.


Assuntos
Auscultação , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial , Oscilometria , Esfigmomanômetros
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; (6): 302-306, 2022.
Artigo em Chinês | WPRIM | ID: wpr-928909

RESUMO

Hyperbaric oxygen therapy is a method of breathing pure oxygen or high-concentration oxygen in a highpressure environment to treat hypoxic diseases and related diseases. According to clinical verification, this therapy has an irreplaceable effect on certain diseases and has gradually become a comprehensive clinical treatment. One of the main methods of certain diseases is widely recognized by the medical field at home and abroad. The development history, treatment principles, key technologies, and future development trends of hyperbaric oxygen are discussed in detail, provide a research direction for the development of hyperbaric oxygen therapy in the future, and at the same time, it has also improved physicians' awareness of hyperbaric oxygen therapy, so as to improving Industry influence.


Assuntos
Oxigenoterapia Hiperbárica , Oxigênio/uso terapêutico , Projetos de Pesquisa
4.
International Eye Science ; (12): 1193-1195, 2016.
Artigo em Chinês | WPRIM | ID: wpr-637810

RESUMO

?AIM:To compare the curative effect of conjoint fascial sheath( CSF) suspension and levator muscle resection for moderate or severe congenital ptosis.?METHODS: Forty - three patients ( 74 eyes ) with moderate or severe ptosis were treated by CSF suspension or levator muscle resection randomly, and followed up for 6mo. The normalization rates of the two operations were then compared by statistical method, and the complications of the two operations were analyzed.?RESULTS: The two operations appeared no significant difference on the normalization rate for moderate congenital ptosis (P>0. 05), while the normalization rate of CSF suspension on severe congenital ptosis was significantly higher than that of levator muscle resection (P<0. 05). Less complication was happened in the CSF suspension group than in the levator muscle resection group.?CONCLUSION:CSF suspension is more effective on the treatment of severe congenital ptosis than levator muscle resection, and has advantages such as less trauma, repeatable, and less complication.

5.
Zhonghua zhong liu za zhi ; (12): 751-754, 2014.
Artigo em Chinês | WPRIM | ID: wpr-272298

RESUMO

<p><b>OBJECTIVE</b>To detect the frequency of ROS1 gene rearrangement in non-small cell lung cancer ( NSCLC) patients by FISH, and to analyze the relationship between ROS1 gene rearrangement and clinical features (including age, sex, stage, histology, smoking history) with NSCLC.</p><p><b>METHODS</b>The ROS1 gene rearrangement in histological sections of 1 652 NSCLC tissues was detected by FISH. The extracted RNA was amplified and the sequences were analyzed by Sanger sequencing for ROS1-positive samples.</p><p><b>RESULTS</b>ROS1 rearrangement was identified in 53 specimens (3.2%) from the 1 652 NSCLC tissues. Among these positive cases, 15 were CD74-ROS1, 13 were SLC34A2-ROS1, 13 were SDC4-ROS1 and 12 were TPM3-ROS1. The frequency of ROS1 rearrangement was significantly higher in never-smoking patients (49 cases) than in smokers (4 cases) (P < 0.05). Patients with ROS1-positive NSCLC tended to be younger and there was no significant difference in sex (P > 0.05). All of the ROS1-positive samples were adenocarcinomas, with a tendency toward higher clinical stage (P < 0.05).</p><p><b>CONCLUSIONS</b>ROS1 rearrangement has diversity, and may be defined as a new molecular subtype of NSCLC. ROS1 rearrangement tends to occur in younger, and never-smoker lung adenocarcinoma patients.</p>


Assuntos
Humanos , Adenocarcinoma , Genética , Carcinoma Pulmonar de Células não Pequenas , Genética , Metabolismo , Rearranjo Gênico , Hibridização in Situ Fluorescente , Neoplasias Pulmonares , Genética , Oncogenes , Proteínas Tirosina Quinases , Genética , Proteínas Proto-Oncogênicas , Genética , Metabolismo
6.
Zhonghua Bing Li Xue Za Zhi ; (12): 399-402, 2014.
Artigo em Chinês | WPRIM | ID: wpr-292280

RESUMO

<p><b>OBJECTIVE</b>To establish a repeat-free ROS1 gene fluorescence in situ hybridization (FISH) probe, and to compare its efficacy with those of commercial FISH probes in non-small cell lung cancer.</p><p><b>METHODS</b>The probe was constructed by combining human Cot-1 DNA genome into double-stranded sequence, and then digested by duples specific nuclease to establish a repeat-free sequence. The final repeat-free ROS1 FISH probe was labeled by red and green fluoresceins.</p><p><b>RESULTS</b>Compared with the commercialized probe, repeat-free FISH probe exhibited excellent efficiency and low signal to noise ratio (SNR) in samples. There was statistical significance in the difference between the hybridization rate of these two probes (P < 0.05) , but there was no difference between the accuracy rate (P > 0.05).</p><p><b>CONCLUSION</b>The repeat-free ROS1 FISH probe significantly improves the probe hybridization efficiency and SNR in non-small cell lung cancer (NSCLC), resulting in an increased accuracy of detection.</p>


Assuntos
Humanos , Carcinoma Pulmonar de Células não Pequenas , Diagnóstico , Genética , Corantes Fluorescentes , Hibridização in Situ Fluorescente , Proteínas Tirosina Quinases , Genética , Proteínas Proto-Oncogênicas , Genética
7.
Artigo em Chinês | WPRIM | ID: wpr-405655

RESUMO

Objective To construct human PLAGL2 siRNA expression DNA plasmid and study the interfering effect on gene expression in H441 cells. Methods H441 cells were transfected with PLAGL2 siRNA expression DNA plasmid with Fu-gene6. Real time PCR and Western blot were employed to detect the interfering effect on the expression of PLAGL2.SP-CSP-B mRNA and protein in wildtype and PLAGL2 siRNA expression DNA plasmid transfected H441 cells respectively. Results Real time PCR revealed that,as compared with wildtype H441 cells, the expression level of PLAGL2 mRNA in PLAGL2 siRNA plasmid transfected H441 cells was significantly reduced(P<0. 05) ,but that of SP-C mRNA in PLAGL2 siRNA plasmid transfected H441 cells was significantly increased(P<0. 05). Western blot showed that,as compared with wildtype H441 cells, the expression level of PLAGL2 protein in PLAGL2 siRNA DNA plasmid transfected H441 cells was significantly reduced(P< 0. 05). Conclusion Human PLAGL2 siRNA expression DNA plasmid was constructed successfully,and its transfection into the H441 cells could effectively inhibit the PLAGL2 expression,and simultaneously promote the expression of SP-C.

8.
Zhongguo Yi Liao Qi Xie Za Zhi ; (6): 455-458, 2008.
Artigo em Chinês | WPRIM | ID: wpr-309550

RESUMO

This article introduces a measuring method for invasive blood pressure based on SecWave technology and a testing method of effectiveness based on IBP database and simulator. Besides, quantified indexes are set out for the accuracy evaluation, such as static pressure accuracy, accuracy of dynamic pressure pulse wave recognition, pulse rate and the response time, so as to provide an important reference method of effectively objective evaluation for invasive blood pressure measurements.


Assuntos
Humanos , Algoritmos , Processamento Eletrônico de Dados , Métodos , Determinação da Pressão Arterial , Métodos
9.
Zhongguo Yi Liao Qi Xie Za Zhi ; (6): 439-442, 2007.
Artigo em Chinês | WPRIM | ID: wpr-323237

RESUMO

This article introduces a method of practical noninvasive blood pressure measurement techniques and its key technical points from the view of products , and it gives detailed requirements for us to evaluate the efficiency of these techniques, The evaluation results are presented here by the testing examples guiding us to a correct evaluation of noninvasive blood pressure measurement techniques.


Assuntos
Determinação da Pressão Arterial , Métodos
10.
Artigo em Chinês | WPRIM | ID: wpr-241092

RESUMO

The circuit of a monitoring system for respiratory mechanical parameters is designed based on the detection of respiratory flow and pressure. Breaking through the restrictions of traditional methods that can only monitor respiratory rate, this design is able to monitor more than 10 respiratory parameters simultaneously and thus provides a good technical support for improving the properties of homemade monitors.


Assuntos
Humanos , Resistência das Vias Respiratórias , Simulação por Computador , Computadores , Desenho de Equipamento , Monitorização Fisiológica , Métodos , Mecânica Respiratória , Design de Software , Terapia Assistida por Computador , Métodos , Transdutores