RESUMO
ABSTRACT Background There are no data of reference values on 24-hour multichannel intraluminal impedance and pH (pH-MII) monitoring in Argentinian populations. Objective Our aim was to obtain the normal values of pH-MII variables among healthy asymptomatic volunteers in a metropolitan Health Care Center of Argentina, and to compare them with data already published from other regions around the world. Methods A cross-sectional study was undertaken in a tertiary referral center in Buenos Aires. We enrolled healthy subjects and asked them to undergo esophageal pH-MII 24hours monitoring. pH-MII variables were recorded and described. Results Median reflux events was 20.5 (25-75%, 95%) interquartile range: (14-46, 50) and proximal reflux episodes was 2.5 (0-10, 11). Sixty percent were acid reflux episodes: 12 (5-29, 38), representing a relatively low value when compared to those reported in European, American and Chinese populations. Conclusion Our study shows the first reference of normal values of gastroesophageal reflux in an Argentinian population. We found a total number of reflux events and a total number of proximal reflux events lower than what was reported until this date by other authors.
RESUMO Contexto Não há dados de valores de referência sobre o monitoramento de impedância intraluminal multicanal 24 horas e monitoramento de pH (pH-MII) em populações argentinas. Objetivo O objetivo foi obter os valores normais das variáveis pH-MII entre voluntários assintomáticos saudáveis em um centro metropolitano de saúde da Argentina, e compará-los com dados já publicados de outras regiões do mundo. Métodos Estudo transversal foi realizado em um centro de referência terciário em Buenos Aires. Foram recrutados indivíduos saudáveis para se submeterem ao monitoramento esofágico pH-MII 24 horas. As variáveis pH-MII foram registradas e descritas. Resultados A média de eventos de refluxo foi de 20,5 (25-75%, 95%) entre os episódios interquartis: (14-46, 50) e os episódios de refluxo proximal foram de 2,5 (0-10, 11). Sessenta por cento foram episódios de refluxo ácido: 12 (5-29, 38), representando um valor relativamente baixo quando comparado com os relatados em populações europeias, americanas e chinesas. Conclusão Nosso estudo mostra a primeira referência de valores normais de refluxo gastroesofágico em uma população argentina. Encontramos um número total de eventos de refluxo e um número total de eventos de refluxo proximal menor do que o relatado até esta data por outros autores.
RESUMO
ANTECEDENTES: la colangiografía endoscópica enfrenta el desafío del control de costos en un área de constantes avances tecnológicos. La reutilización es el uso de un dispositivo médico más veces de las especificadas por el fabricante. Esta práctica se halla precedida por las maniobras de reprocesamiento y amparada por la legislación vigente. OBJETIVOS: cuantificar la reducción en el costo de los insumos y evaluar las complicaciones. Método: estudio prospectivo, descriptivo y análisis sobre minimización de costos comparando la reutilización de dispositivos médicos con el uso único de los mismos. RESULTADOS: durante un período de tres meses se realizaron 144 estudios. Con la estrategia de reutilización, se utilizaron: 9 papilótomos, 12 guías hidrofílica, 3 canastillas de Dormia, 4 balones extractor, 5 balones dilatadores y 2 cuchillos de precorte. Representó un costo total de U$ 10 943 (promedio de costo de materiales por cada estudio: U$ 76). Con la estrategia de uso único se hubieran utilizado: 144 papilótomos, 144 alambres guías, 24 canastillas de Dormia, 20 balones dilatadores, 72 balones extractores y 24 agujas de precorte. Esta estrategia hubiera generado un costo total de U$ 126 280 (promedio por estudio U$ 877). Al comparar los valores entre ambas estrategias observamos una minimización significativa en el costo (p< 0.001). No se registraron complicaciones. Conclusión: Con la estrategia de reutilización de los DM los costos se minimizaron significativamente sin generarse complicaciones
BACKGROUND: cost control is challenging endoscopic cholangiography in an area of constant technological advances. Reusing is using a medical device more times than what was specified by the manufacturer. This practice is preceded by reprocessing maneuvers and protected by the applicable laws. OBJECTIVES: to quantify the cost reduction of supplies and assess the complications. Method: a prospective descriptive study and an analysis of cost minimization by comparing the reuse and the single use of medical devices. Results: 144 studies were conducted during a period of three months. The reuse strategy included: 9 papillotomes, 12 hydrophilic guide wires, 3 Dormia baskets, 4 balloon extraction catheters, 5 balloon dilatation catheters and 2 pre-cut knives. It accounted for a total cost of USD 10,943 (average cost of materials per study: USD 76). The single-use strategy would have included: 144 papillotomes, 144 hydrophilic guide wires, 24 Dormia baskets, 20 balloon extraction catheters, 72 balloon dilatation catheters and 24 pre-cut needle knives. This strategy would have amounted to a total cost of USD 126,280 (average per study: USD 877). By comparing the values of both strategies, a significant minimization is seen in the cost (p< 0.001). No complications were seen. CONCLUSION: the strategy for reusing MD involveda significant minimization of costs without causing any complications.
Assuntos
Colangiografia , Custos e Análise de Custo , Técnicas de Diagnóstico do Sistema Digestório , Administração de Materiais no Hospital , ReciclagemRESUMO
La colangiopancreatografía retrógrada endoscópica (CPRE) se considera el tratamiento de primera línea para el drenaje biliar en pacientes con cáncer de páncreas. En los casos de fracaso por CPRE, generalmente se realiza un drenaje biliar transparietohepático o una derivación biliar quirúrgica. En la última década, las indicaciones y la utilidad de la ecoendoscopia en pacientes con cáncer de páncreas han ido creciendo, y se han informado numerosos casos de drenajes biliares guiados por ecoendoscopia como una alternativa al drenaje biliar percutáneo o quirúrgico en fracasos en la CPRE. Nuestro objetivo es comunicar un caso con cáncer de páncreas localmente avanzado que se presentó con ictericia indolora y síndrome coledociano con obstrucción biliar y duodenal, en el que se realizó una colédoco-duodenostomía guiada por ecoendoscopia mediante la colocación de una prótesis metálica autoexpandible.
Endoscopic retrograde cholangiopancreatography (ERCP) is considered the first-approach for biliary drainage. In cases of ERCP failure, patients are usually referred for percutaneous transhepatic biliary drainage or surgical biliary bypass. In the last decade, the indications of endoscopic ultrasound (EUS) in the management of patients with pancreatic cancer have increased, and numerous cases of EUS-guided biliary drainage have been reported in patients with failures during the ERCP. Our goal is to report a patient with locally advanced pancreatic cancer who presented with painless jaundice and cholestasis with biliary and duodenal obstruction. A EUS-guided choledochoduodenostomy was performed by placement of a self-expanding metal stent.
Assuntos
Humanos , Feminino , Idoso de 80 Anos ou mais , Neoplasias Pancreáticas/cirurgia , Coledocostomia/métodos , Adenocarcinoma/cirurgia , Duodenoscopia/métodos , Obstrução Duodenal/cirurgia , Neoplasias Pancreáticas/diagnóstico por imagem , Adenocarcinoma/diagnóstico por imagem , Colestase/complicações , Ultrassonografia , Icterícia Obstrutiva/complicações , Obstrução Duodenal/diagnóstico por imagem , Stents Metálicos AutoexpansíveisRESUMO
Se describen las temáticas abordadas durante los días 5 y 6 de junio de 2008 en las XII Jornadas Internacionales de Gastroenterología y Endoscopía Digestiva en la ciudad de La Plata, las cuales son organizadas anualmente por la Sociedad de Gastroenterología de la provincia de Buenos Aires, el Grupo Endoscópico de La Plata y la Cátedra de Postgrado en Gastroenterología. Los temas más salientes abordados en las recientes jornadas estuvieron relacionados con: Hipertensión portal: Fisiopatología, Hemorragia, Varicela, Indicaciones de TIPS (derivación transyugolo intrahepática portosistémica) y patología bilio pancreática: CA de Páncreas, Tratamiento endoscópico de la Pancreatitis Crónica, Ecoendoscopía en patología biliopancreática. La conferencia "CA de Páncreas: Tratamiento endoscópico vs. quirúrgico" estuvo a cargo del Dr. Everson Artifon, responsable de la sección de patología bilio-pancreática del Servicio de Endoscopía del hospital de clínica de San Pablo, a cargo del Dr. Paulo Sakai, destacado referente de nuestra especialidad en Sudamérica.