Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Arq. bras. oftalmol ; 75(3): 170-173, maio-jun. 2012. tab
Artigo em Português | LILACS | ID: lil-644442

RESUMO

OBJETIVOS: Comparar a tela de Amsler modificada com o campo visual Humphrey® 10-2 vermelho nos usuários de cloroquina, na detecção da maculopatia precoce, e correlacionar com as variáveis de risco. MÉTODOS: Foram analisados 116 olhos de 58 pacientes, acompanhados no Serviço de Oftalmologia do Hospital do Servidor Público Estadual de São Paulo, entre abril de 2006 e abril de 2008. Todos os usuários tinham fundo de olho normal e mais de dois anos de terapia com cloroquina. Os participantes tiveram seus dados clínicos avaliados e foram submetidos ao exame da acuidade visual corrigida, biomicroscopia de fundo, campimetria macular automatizada e tela de Amsler. RESULTADOS: A incidência da maculopatia precoce foi de 7 a 10%, dependendo do exame considerado. A concordância entre a tela de Amsler e o campo visual foi baixa. Para o grupo de olhos que apresentaram ambos os exames alterados, houve significância estatística com a alta dose diária, dose cumulativa elevada e baixa acuidade visual; a idade do paciente e a duração do tratamento não mostraram boa correlação nestes casos, mas suas médias (67,4 anos e 8,4 anos, respectivamente) situaram-se dentro da faixa dos fatores de alto risco. CONCLUSÕES: O estudo sugere que a tela de Amsler pode ser útil na complementação das informações do campo visual no rastreamento periódico da retinopatia por cloroquina, sobretudo naqueles com fatores de alto risco bem estabelecidos, selecionando melhor os candidatos à realização de testes objetivos, como o OCT de alta resolução e o ERG multifocal.


PURPOSE: To compare the modified Amsler grid to the Humphrey® 10-2 red visual field in chloroquine users for the detection of early maculopathy, and to correlate with the risk variables. METHODS: The study included 116 eyes of 58 patients followed at the Department of Ophthalmology of Hospital do Servidor Público Estadual de São Paulo, from April, 2006 to April, 2008. All users had normal fundus and more than 2 years of chloroquine therapy. Their clinical data were evaluated and they underwent visual acuity examination, fundus biomicroscopy, visual field and Amsler grid. RESULTS: The incidence of early maculopathy was 7 to 10%, depending on the examination considered. The agreement between the Amsler grid and visual field was low. There was statistical significance with the use of high daily dose, elevated cumulative dose and low visual acuity in patients whose eyes had both abnormal tests; patient age and duration of treatment did not show good correlation in these cases, but their averages (67.4 years and 8.4 years, respectively) were within the range of high risk factors. CONCLUSIONS: The study suggests that Amsler can be useful in complementing the information on the visual field for chloroquine retinopathy periodic screening, especially for those patients who present high risk factors well established, selecting better candidates for objective tests, such as HD OCT and mfERG.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Antimaláricos/toxicidade , Cloroquina/toxicidade , Degeneração Macular/induzido quimicamente , Degeneração Macular/diagnóstico , Retina/efeitos dos fármacos , Testes de Campo Visual/métodos , Fatores Etários , Técnicas de Diagnóstico Oftalmológico , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Risco , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA