Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Braz. dent. j ; 34(3): 25-32, May-June 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1447604

RESUMO

Abstract This study aimed to evaluate the tissue repair capacity of four bioceramic endodontic sealers by quantifying type I and III collagen fibers. The following sealers were tested: EndoSequence BC Sealer (Brasseler, Brasseler, Savannah, USA), Bio C Sealer (Angelus, Londrina, Brazil), Bioroot RCS (Septodont, Santa Catarina, Brazil), and Sealer Plus BC (MKLife, Porto Alegre, Brazil). Polyethylene tubes 1.5 mm in diameter and 1 cm in length containing the endodontic sealers were implanted in the subcutaneous tissue of five rats (Rattus norvegicus albinus, Wistar lineage). After 14 days, the animals were euthanized, and collagen fibers were quantified from the histological tissue sections. Given a non-normal distribution of the data, a gamma regression with log link function was employed and implemented through the generalized linear models module, was used to test whether there was a significant difference between the sealers. The pairwise comparison was performed using Least significant difference. There were significant differences between the sealers for type I (p=0.001), type III (p=0.023), and total collagen (p=0.002). Overall, Bioroot sealer was statistically superior to the other sealers, except in the analysis of type III collagen, in which there was no difference between the Bioroot sealer and Bio C Sealer sealer and the control group (p>0.05). Bioroot RCS bioceramic endodontic sealer stimulates a greater production of collagen.


Resumo Este estudo visou avaliar a capacidade de reparação de tecidos de quatro cimentos endodônticos biocerâmicos através da quantificação de fibras colágenas de tipo I e III. Foram testados os seguintes cimentos: EndoSequence BC Sealer (Brasseler, Brasseler, Savannah, EUA), Bio C Sealer (Angelus, Londrina, Brasil), Bioroot RCS (Septodont, Santa Catarina, Brasil), e Sealer Plus BC (MKLife, Porto Alegre, Brasil). Foram implantados tubos de polietileno de 1,5 mm de diâmetro e 1 cm de comprimento contendo os cimentos endodônticos no tecido subcutâneo de cinco ratos (Rattus norvegicus albinus, linhagem Wistar). Após 14 dias, os animais foram eutanasiados e as fibras colágenas foram quantificadas a partir de cortes histológicos do tecido. Diante de uma distribuição não-normal dos dados, uma regressão gama com função de ligação log, implementada por meio do módulo de modelos lineares generalizados, foi empregada para testar se havia diferença significativa entre os cimentos. A comparação dois a dois foi realizada utilizando Least significant difference. Houve diferença significativa entre os cimentos para os colágenos tipo I (p=0,001), tipo III (p=0,023) e colágeno total (p=0,002). No geral, o cimento Bioroot foi estatisticamente superior aos demais cimentos, com exceção na análise do colágeno tipo III na qual não houve diferença entre o cimento Bioroot e o cimento Bio C Sealer e o grupo controle (p>0,05). O cimento endodôntico biocerâmico Bioroot RCS foi capaz de estimular uma maior produção de colágeno.

2.
RGO (Porto Alegre) ; 70: e20220057, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1406481

RESUMO

ABSTRACT Objective: The aim of this study was to evaluate the effectiveness of XP-endo Finisher (XP) on removal of the smear layer in root canals by comparing different irrigation protocols. Methods: Seventy-two human single-rooted teeth were similarly instrumented using R25 Reciproc files (VDW, Munich, Germany) applied in reciprocating mode with a VDW GOLD endo motor (VDW, Munich, Germany). The working length was determined at 1 mm short of the apical foramen. The canals were irrigated with 5 mL of 2.5% sodium hypochlorite during instrumentation. The teeth were divided at random into six groups (n=12). A control group, which was not submitted to the final irrigation protocol, and five experimental groups with different irrigants and agitation techniques: EDTA/File, EDTA/XP, EDTA/Passive Ultrasonic Irrigation (PUI), Distilled Water (DW)/XP, and DW/PUI). Smear layer removal quality scores were assessed in the apical, middle, and cervical thirds of the root canal based on images obtained by scanning electron microscopy. Data were analyzed using the Kruskal-Wallis test, followed by two-by-two comparisons with the Dunn test (α=5%). Results: EDTA/File, EDTA/PUI, and EDTA/XP groups demonstrated significantly lower scores than the other groups (P<0.05) in all thirds evaluated. No significant difference was observed between the groups in which distilled water was used and the control group in all thirds evaluated (P> 0.05). Conclusion: The XP-endo Finisher file did not increase the efficiency of EDTA in removal of the smear layer in root canals.


RESUMO Objective: Avaliar a eficácia do XP-endo Finisher (XP) na remoção da smear layer em canais radiculares, comparando diferentes protocolos de irrigação. Métodos: Setenta e dois dentes humanos unirradiculares foram similarmente instrumentados usando limas R25 (VDW, Munich, Germany) aplicadas no modo reciprocrantes em um motor endodôntico VDW GOLD (VDW, Munich, Germany). O comprimento de trabalho foi determinado a 1 mm aquém do forame apical. Os canais foram irrigados com 5 mL de hipoclorito de sódio 2,5% durante a instrumentação. Os dentes foram divididos aleatoriamente em seis grupos (n=12). Um grupo controle, que não foi submetido ao protocolo final de irrigação, e cinco grupos experimentais com diferentes irrigantes e técnicas de agitação: EDTA/Lima, EDTA/XP, EDTA/Irrigação Ultrassônica Passiva (IUP), Água destilada (AD)/XP, e AD/IUP). Os escores de qualidade de remoção da camada de smear layer foram avaliados nos terços apical, médio e cervical do canal radicular com base em imagens obtidas por microscopia eletrônica de varredura. Os dados foram analisados pelo teste de Kruskal-Wallis, seguido de comparações dois a dois pelo teste de Dunn (α = 5%). Resultados: Os grupos EDTA/lima, EDTA/PUI e EDTA/XP demonstraram escores significativamente menores que os outros grupos (P <0,05). Não foi observada diferença entre os grupos que utilizaram água destilada e o grupo controle em todos os terços avaliados (P> 0.05). Conclusão: A lima XP-endo Finisher não aumentou a eficiência do EDTA na remoção da smear layer em canais radiculares.

3.
Rev. odontol. UNESP (Online) ; 51: e20220043, 2022. tab
Artigo em Português | LILACS, BBO | ID: biblio-1424239

RESUMO

Introdução: a inovação dos métodos de fotopolimerização foi proposta na tentativa de diminuir o estresse de contração de polimerização das resinas compostas e proporcionar maior conforto ao paciente, reduzindo o tempo de atendimento odontológico. Objetivo: avaliar a microdureza de duas resinas compostas nanoparticuladas submetidas a diferentes técnicas de polimerização. Material e método: quarenta espécimes foram divididos em quatro grupos (n=10) da seguinte forma: Filtek Z350 XT® + técnica imediata (GI); Filtek One Bulkfill® + técnica imediata (GII); Filtek Z350 XT® + técnica de pulso tardio (GIII); Filtek One Bulkfill® + técnica de pulso tardio (GIV). Após o armazenamento em água destilada à temperatura ambiente, os corpos de prova foram direcionados para a medição de microdureza. Utilizou-se teste T para comparação de técnicas e teste Two-Way ANOVA para calcular os efeitos das resinas compostas, técnicas de polimerização e interações referentes à variável dependente (p ≤0,05). Resultado: a resina Filtek Z350 XT® apresentou maior dureza na técnica imediata (GI - 312,45 ± 64,37) e pulso tardio (GIII - 244,50 ± 75,63) comparado à resina Filtek One Bulkfill®, em ambas as técnicas. Observaram-se maiores valores de dureza referentes à técnica imediata, com diferença estatística significativa em relação à resina testada (p = 0,04 - Filtek Z350 XT®; p = 0,03 - Filtek One Bulkfill®). Ambos os fatores isolados (resina e técnicas) apresentaram efeito nos valores de microdureza (p = 0,02 e p < 0,01, respectivamente). Conclusão: a técnica convencional demonstrou atingir maiores valores de dureza quando comparada à técnica de polimerização alternativa.


Introduction: the innovation of photopolymerization methods was proposed in an attempt to reduce the polymerization shrinkage stress of composite resins and also provide more comfort to patient reducing the chair time. The aim of this in vitro study was to assess the microhardness of two nanofilled composite resins subject to different curing techniques. Objective: assess the microhardness of two nanofilled composite resins subject to different curing techniques. Material and method: forty specimens were divided into four groups (N=10) as follows: Filtek Z350 XT® + immediate technique (GI); Filtek One Bulkfill® + immediate technique (GII); Filtek Z350 XT® + delayed pulse technique (GIII); Filtek One Bulkfill® + delayed pulse technique (GIV). After storage in distilled water at room temperature the specimens were assessed for microhardness measurement. T-test was used for comparison of techniques and two-way ANOVA used to calculate the effects of composite resins, curing techniques and their interactions on dependent variable (p set at 0.05). Result: Filtek Z350 XT® resin presented greater hardness on immediate technique (GI - 312,45 ± 64.37) and delayed pulse (GIII - 244,50 ± 75.63) compared to Filtek One Bulkfill® under both techniques. Overall, it was observed greater hardness values under immediate technique with a significant statistical difference apart of tested resin (p = 0.04 - Filtek Z350 XT®; p = 0.03 - Filtek One Bulkfill®). Both isolated factors (resin and techniques) presented effect on microhardness values (p = 0.02 and p < 0.01, respectively). Conclusion: the conventional technique demonstrated to reach higher hardness values when compared to the alternative polymerization technique


Assuntos
Técnicas In Vitro , Análise de Variância , Resinas Compostas , Cura Luminosa de Adesivos Dentários , Testes de Dureza
4.
Braz. oral res. (Online) ; 31: e76, 2017. graf
Artigo em Inglês | LILACS | ID: biblio-952131

RESUMO

Abstract To evaluate the influence of rewetting solutions on bond strength to root dentin of conventional gutta-percha (GP) or niobium phosphate glass-based gutta-percha (GNb) associated with a bioceramic sealer. The root canals of 80 human mandibular premolars were prepared using nickel-titanium instruments and irrigation with sodium hypochlorite and EDTA. The teeth were randomly divided into four groups according to the gutta-percha used: GNb or GP associated with EndoSequence BC Sealer (BC) and the solution for rewetting dentin before filling (distilled water; phosphate buffer saline solution - PBS; simulated body fluid - SBF; or no solution). The root canals were filled with a single cone using warm vertical condensation. Micropush-out bond strengths associated with the filling materials in slices from middle root thirds was determined 30 days after root filling. The failure mode was analyzed with stereoscopic lens. The data were statistically analyzed by two-way ANOVA and Holm-Sidak test (p < 0.05). There was significant difference in the types of gutta-percha (p < 0.001) and in the different rewetting solutions (p = 0.003). The interaction between gutta-percha and rewetting solutions was not significant (p = 0.53). The SBF solution provided an increase in bond strength for both gutta-percha solutions. The GNb+BC (3.42 MPa) association increased bond strength when compared with GP+BC (2.0 MPa). The use of SBF as a dentin rewetting solution increased bond strength in the groups studied. Association of GNb with bioceramic sealer was beneficial, increasing the bond strength to dentin when compared with the association with GP.


Assuntos
Humanos , Soluções/química , Cerâmica/química , Colagem Dentária/métodos , Dentina/efeitos dos fármacos , Guta-Percha/química , Valores de Referência , Propriedades de Superfície/efeitos dos fármacos , Materiais Biocompatíveis/química , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Preparo de Canal Radicular/métodos , Falha de Restauração Dentária , Dentina/química , Nióbio/química
5.
RGO (Porto Alegre) ; 61(2): 193-197, abr.-jun. 2013. tab, ilus
Artigo em Inglês | LILACS | ID: lil-689469

RESUMO

Objective: This study assessed the effect of coronal flaring with the Gates-Glidden (GG) bur, La Axxess (LA) bur, and SX file on the area, circularity, and residual dentin thickness in the furcal direction of mandibular first molar root canals. Methods: The mesiolingual and mesiobuccal canals of twenty-one mandibular first molars were instrumented. The teeth were embedded in acrylic resin, and after coronal flaring, the roots were cut perpendicularly to their long axis 2 mm below the cementoenamel junction. The sections were photographed before and after flaring with GG bur no. 3, LA bur no. 1 and SX file. The area, circularity, and residual dentin thickness in the furcal direction were calculated by the software Image J. Results: Before instrumentation, the canals had a mean area of 0.56mm2±0.37 and mean circularity of 0.31±0.08. After flaring with the GG, SX and LA instruments, the mean areas were 0.68mm2±0.20, 0.64mm2±0.18, and 0.85 mm2±0.23, respectively; and the mean circularities were 0.39±0.08, 0.35±0.08, and 0.39±0.06, respectively. The areas achieved with the LA bur and SX file were statistically different (p<0.05). The final circularities (p>0.05) and residual dentin thicknesses in the furcal direction (p>0.05) did not differ between the groups. Conclusion: Coronal flaring with the study instruments was safe. The SX file achieved the smallest area. Circularity and residual dentin thickness in the furcal direction were not affected by the different instruments. No instrument was capable of achieving a circularity greater than 0.5.


Objetivo: Avaliar o efeito no preparo cervical da broca Gates-Glidden (GG), La Axxess (LA) e lima SX na área, circularidade e na espessura residual dentinária voltada para a região de furca de canais radiculares dos primeiros molares inferiores. Métodos: Foram utilizados canais mésio-vestibulares e os mésio-linguais de vinte e um primeiros molares inferiores. Os dentes foram incluídos em resina acrílica e após a abertura coronária foram seccionados 2mm abaixo da junção amelo-cementária. As secções foram fotografadas antes e após o preparo cervical usando GG n. 3, LA n. 1 e SX. A área, a circularidade e o remanescente de dentina voltada para a furca foram calculados com auxílio do programa computacional Image J. Resultados: Antes do preparo cervical os canais apresentaram 0,56mm2 (±0,37) para área e 0,31 (±0,08) para circularidade. Após o uso da GG, SX e LA os valores médios para área foram 0,68 mm2 (±0,20), 0,64 mm2 (±0,18) e 0,85 mm2 (±0,23) e para circularidade de 0,39 (±0,08), 0,35 (±0,08) e 0,39 (±0,06), respectivamente. Houve diferença estatística significante entre a área para LA e SX (p<0,05). Não houve diferença para à circularidade (p>0,05) e nem para à espessura residual de dentina da furca (p>0,05). Conclusão: O preparo cervical realizado com diferentes instrumentos apresentou adequada segurança sendo que a lima SX apresentou os menores valores de área. A circularidade e a quantidade de dentina residual na região de furca não foram influenciadas pelos diferentes instrumentos. Nenhum instrumento resultou em valores de circularidade maior que 0.5.


Assuntos
Cavidade Pulpar , Endodontia
6.
Rev. dor ; 14(3): 187-191, jul.-set. 2013. graf, tab
Artigo em Português | LILACS | ID: lil-690304

RESUMO

BACKGROUND AND OBJECTIVES: University professors are part of a category of professionals constantly submitted to stress, which may trigger a temporomandibular disorder (TMD). By recognizing this relationship, this study aimed at evaluating the prevalence and severity of TMD in university professors. METHODS: A sample of 200 individuals of both genders, above 25 years of age, who were still not diagnosed with TMD, was divided in two groups: Group I, made up of university professors, and Group II made up of individuals of any other professional activity, different from teaching. Volunteers were asked to fill a historical questionnaire which allowed a classification of the presence and severity of TMD. RESULTS: Participated in this study 95 males and 105 females. With regard to TMD severity in Group I, it was observed that 62.7% of evaluated individuals were classified as having mild TMD; 25.3% as having moderate TMD; and 12% as having severe TMD. In Group II, 73.9% had mild TMD; 24.6% had moderate TMD; and 1.4% had severe TMD. CONCLUSION: The prevalence of TMD among professors was not different from the group of non professors. When professors had TMD, the level severity was higher as compared to non professors.


JUSTIFICATIVA E OBJETIVOS: O professor de ensino superior faz parte de uma categoria de profissionais que é submetida constantemente a estresse, podendo desencadear uma disfunção temporomandibular (DTM). Ao reconhecer essa relação, este trabalho teve como objetivo avaliar a prevalência e grau de gravidade de DTM em professores de ensino superior. MÉTODOS: Uma amostra de 200 indivíduos, de ambos os gêneros, maiores de 25 anos, que ainda não tinham diagnóstico de DTM, foi dividida em dois grupos: o Grupo I, formado por indivíduos que exerciam a profissão de professor de ensino superior e o Grupo II, formado por indivíduos que exerciam qualquer outra atividade profissional desvinculada da docência. Aos voluntários, foi solicitado o preenchimento de um questionário anamnésico que permitiu estabelecer uma classificação em relação à presença e ao grau de gravidade da DTM. RESULTADOS: Foram avaliados 95 homens e 105 mulheres. Em relação ao grau de gravidade de DTM no Grupo I, detectou-se que 62,7% dos avaliados foram classificados como portadores de DTM leve; 25,3% como portadores de DTM moderada; e 12% como portadores de DTM grave. No Grupo II, constatou-se que 73,9% como portadores de DTM leve; 24,6% DTM como portadores de DTM moderada; e 1,4% como portadores de DTM grave. CONCLUSÃO: A prevalência de DTM em professores não foi diferente da encontrada no grupo de não professores; quando professores foram acometidos por DTM, o grau de gravidade foi maior quando comparado com o grupo de não professores.


Assuntos
Dor Facial , Prevalência , Articulação Temporomandibular
7.
RSBO (Impr.) ; 10(3): 234-239, Jul.-Sep. 2013. graf, tab
Artigo em Inglês | LILACS | ID: lil-695942

RESUMO

Introduction: Biomechanical preparation must provide a taper shape at crown-apex direction for root canal resulting in adequate space for irrigation and enabling an effective obturation. However, this stage requires a cervical preparation aiming to remove the interferences to make the access to the apical portion easy for instrumentation. Objective: To evaluate in vitro the effect of coronal flaring on the root canal area and in the circularity of mesial canals of lower molars after using Gates Glidden, La Axxess, Sx file or a ultrasonic TU-24tip. Material and methods: Twenty-four lower molars had their roots embedded into acrylic resin. Then the roots were sectioned horizontally at 2 mm below the cement-enamel junction. The sections were photographed before and after the different coronal flaring. All images were analyzed using Image J software to calculate the root canal area and the circularity of the root canal. One-way Anova was used to compare the circularity among the groups, while Kruskal-Wallis test was used for comparing the areas. A Pearson test was used to correlate root canal area and circularity data. Results: There was no significant difference among the groups neither for the circularity (p > 0.05) nor for the root canal area (p > 0.05). There was observed a significant inverse correlation between the root canal area and the circularity (r2 = 0.135; p < 0.05). Conclusion: Different coronal flaring techniques have produced similar root canal area and circularity, however the larger the canal area the lower the circularity.

8.
Dent. press endod ; 2(3): 27-31, 2012. tab, graf
Artigo em Português | LILACS, BBO | ID: lil-686410

RESUMO

Objetivo: verificar in vitro se a técnica de odontometria eletrônica, não ultrapassando o forame apical, influencia a precisão da medição. Métodos: foram utilizados 15 dentes incisivos e caninos com ápices completamente formados. Os dentes foram fixados em um modelo de resina e embebidos em alginato, utilizado como meio de condução para a localização eletrônica. Com uma lima tipo K flexofile 20 conectada ao aparelho localizador(Root ZX II, J Morita, Kyoto, Japão), os canais radiculares foram medidos eletronicamente em dois momentos. Primeiro com a lima não ultrapassando o forame apical (técnica alternativa) e, em seguida, coma lima ultrapassando o forame e recuando até a posição de leitura (técnica padrão recomendada pelo fabricante).Nas duas técnicas, quando o leitor digital indicava 0,5, o cursor foi ajustado no ponto de referência e o comprimento medido com paquímetro digital. Após a odontometria eletrônica em cada técnica, foi realizada uma tomada radiográfica periapical. Para medir o grau de concordância entre as duas técnicas, tanto nas medições eletrônicas quanto nas radiográficas, foi utilizada a Correlação Intraclasse (ICC). Resultados: a diferença entre as duas técnicas para as medidas radiográficas foide 0,118 ± 0,170mm) e de 0,086 ± 0,398mm para as medições eletrônicas. As técnicas de odontometria se correlacionaram significativamente, tanto nas medições eletrônicas quanto radiográficas (ICC=0,98; p<0,001,ICC=0,97; p<0,001, respectivamente). Conclusão: a técnica alternativa de localização apical eletrônica, sem ultrapassar o forame apical, mostrou precisão semelhante à técnica padrão preconizada pelo fabricante


Assuntos
Endodontia , Equipamentos de Medição de Riscos , Odontometria , Ápice Dentário
9.
Dent. press endod ; 1(2): 75-80, 2011. tab, ilus
Artigo em Português | LILACS | ID: lil-685800

RESUMO

Objetivo: o objetivo deste estudo foi investigar a relação entre a distância da extremidade do pino intrarradicular ao ápice radiográfico (D) e o grau de periodontite apical(PA). Métodos: foram aleatoriamente selecionadas radiografias periapicais de boca total (14 radiografias periapicais) provenientes de pacientes que procuraram a clínica de Ortodontia do Centro Universitário do Maranhão (São Luis/MA, Brasil). A amostra foi composta pelos primeiros 270 dentes que apresentaram pinos (amostra de conveniência). A análise radiográfica foi realizada utilizando o Índice de Periodontite Apical (IPA). A regressão ordinal foi usada para testar a hipótese nula de que o grau de PA não varia em função de D. O odds ratio (OR) com intervalo de confiança de 95% (IC95%) foi calculado para estimar o risco de ocorrer IPA 4 e 5 em dentes comD≤5mm. Resultados: uma relação significativa entre De IPA foi detectada. Dentes com valores menores de D foram mais propensos a apresentar maiores valores de IPA (R2N=0,167, p<0,05). O risco de dentes com pinos com distância do ápice ≤5mm apresentarem IPA 4 e 5 foi2,82 vezes maior (OR=2,82, p<0,001, IC95%: 1,6-4,76).Conclusão: a distância do pino radicular ao ápice dentário influenciou no grau de PA. Quanto mais próximo opino do ápice, mais alto foi o grau de periodontite apical.Dentes com distância do pino ao ápice menor ou igual a 5mm mostraram quase 3 vezes mais chances de apresentarem elevados índices de periodontite apical


Assuntos
Endodontia , Periodontite Periapical , Obturação do Canal Radicular , Ápice Dentário
10.
RGO (Porto Alegre) ; 57(2): 193-197, abr.-jun. 2009. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-522795

RESUMO

Objetivo: Avaliar a resistência à fratura por torção de limas rotatórias de níquel-titânio com diferentes diâmetros e conicidades. Métodos: Foram utilizados instrumentos Profile (Dentsply Maillerfer, Ballaigues, Suíça) nos diâmetros de 15 a 40 e nas conicidades 0.04 e 0.06. Dez instrumentos de cada diâmetro e conicidade foram testados totalizando cento e vinte limas. O torque máximo (Tmax), até a fratura, foi determinado de acordo com o protocolo no. 28 da American National Standards Institute/American Dental Association. A força máxima era convertida em torque máximo através da fórmula: Tmax = Cargamax x Raio. Resultados: O diâmetro (p<0,001) e a conicidade (p<0,001) influenciaram no torque máximo até a fratura. Com o aumento do diâmetro e da conicidade houve um aumento progressivo do torque. Com o teste da regressão múltipla foi possível estabelecer uma equação relacionando o torque máximo em função do diâmetro (D) e da conicidade (C): Tmax = -1.4 + 0.08D + 10.5C. Conclusão: O aumento do diâmetro e da conicidade promoveu uma ampliação da resistência à fratura por torção. A variação da conicidade de 0.04 para 0.06, em instrumentos com o mesmo diâmetro, elevou em torno de 25% a resistência à fratura por torção.


Objective: To evaluate the resistance to fracture of rotary Ni-Ti files of various diameters and tapers after torsional stress simulation. Methods: Profile (Dentsply Maillerfer, Ballaigues, Suíça) instruments sizes 15 to 40, taper 0.04 and 0.06 were used. Ten instruments of each size and taper were tested, totaling 120 files. The maximum torque (Tmax) until fracture was determined in accordance with the ANSI / ADA Protocol Nº 28 . The maximum force was converted into maximum torque using the formula: Tmax = Loadmax x Radius Results: The diameter (p<0.001) and taper (p<0.001) influenced the maximum torque to fracture. With the increase in diameter and taper there was a gradual increase in the maximum torque. Using the multiple regression method an equation relating the maximum torque to the diameter (D) and the taper (T) was found: Tmax = -1.4 + 0.08D + 10.5T. Conclusion: The increase in diameter and taper promoted an increase in resistance to torsion. The variation of the taper from 0.04 to 0.06 in instruments with the same diameter increased resistance to fracture by torsion by around 25%.


Assuntos
Endodontia/instrumentação , Torque
11.
RGO (Porto Alegre) ; 56(1): 21-25, jan.-mar. 2008. tab
Artigo em Português | LILACS | ID: lil-482681

RESUMO

Objetivos: Comparar a eficácia de três irrigantes utilizados no tratamento de canais radiculares e do extrato de própolis frente à Enterococcusfaecalis. Métodos: Foram utilizadas em teste de difusão em Agar as seguintes substâncias: extrato de própolis produzido pelas abelhas Scaptotrigona sp., hipoclorito de sódio 5%, hidróxido de cálcio e gel de clorexidina 2%. O diâmetro da zona de inibição bacteriana foi medidodepois de 24 horas e os dados foram analisados estatisticamente através do teste Kruskal Wallis. A amostra de extrato de própolis tambémfoi submetida ao teste de diluição para determinar a concentração inibitória mínima. Resultados: Os valores, em milímetros, das médias dos halos de inibição produzidos por difusão das amostras testadas foram: 21,3 (gelde clorexidina); 16,2 (hidróxido de cálcio); 10,9 (extrato de própolis); 7,2 (hipoclorito de sódio). Houve diferença estatística significante entre todas as substâncias testadas (p<0,001). O extrato de própolis apresentou a concentração inibitória mínima de 1mg/mL. Conclusão: O extrato de própolis apresentou uma boa atividade antimicrobiana, sendo maior que hipoclorito de sódio a 5%, entretanto, o gel de clorexidina foi o mais efetivo contra E. faecalis.


Objetivos: To compare the efficacy of three irrigants used in root canal treatment and of propolis extract against Enterococcus faecalis. Methods: The Agar diffusion test was used on the following substances: extract of propolis produced by Scaptotrigona sp., bees; 5% sodium hypochlorite, calcium hydroxide and 2% chlorhexidine gel. The diameter of the bacterial zone of inhibition was measured after 24 hours and the data were statistically analyzed by the Kruskal Wallis test. The propolis extract sample was also submitted to the dilution test to determine the minimum inhibitory concentration. Results: The values, in millimeters, of the inhibition haloes produced by diffusion of the tested samples were as follows: 21.3 (chlorhexidine gel); 16.2 (calcium hydroxide); 10.9 (propolis extract); 7.2 (sodium hypochlorite). There was statistically significant difference among all the substances tested. (p<0.001). Propolis extract presented a minimum inhibitory concentration of 1mg/mL. Conclusion: Propolis extract presented good antimicrobial activity, being more active than 5% sodium hypochlorite, however, the chlorhexidine was the most effective agent.


Assuntos
Clorexidina/farmacologia , Endodontia , Enterococcus faecalis , Hidróxido de Cálcio/farmacologia , Hipoclorito de Sódio/farmacologia , Própole/farmacologia , Irrigantes do Canal Radicular/farmacologia
12.
J. appl. oral sci ; 14(3): 183-187, May-June 2006. tab
Artigo em Inglês | LILACS, BBO | ID: lil-448191

RESUMO

This study investigated the prevalence of apical periodontitis (AP) and its association with endodontically treated teeth in residents of São Luís, MA, Brazil. Two-hundred complete series of periapical radiographs taken over a 10-year period (1993-2003) were retrieved from the files of four prosthesists and five periodontists. The Periapical Index (PAI) was used and the age range, sex, tooth groups, location and association with endodontic treatment (ET) were also analyzed. The Cohen Kappa and Chi-square tests were used for statistical analysis. Out of 200 patients, 135 presented at least one case of AP, which corresponds to a prevalence of 67.5 percent. Of the 5008 teeth examined, 296 had AP and 553 had ET. Therefore, considering the total number of teeth, AP and ET prevalences were 5.9 percent and 11 percent, respectively. Of the 553 endodontically treated teeth, 235 (42.5 percent) were associated with AP. Chi-square test showed a strong correlation between AP and ET (p<0.05). The 40-year-old age group was significantly the most prevalent (p<0.05). There was no association between AP and patient's sex (p>0.05). The maxillary incisors were the most affected group of teeth (p<0.05). AP had predilection for the maxilla and was strongly associated with endodontically treated teeth (p<0.05). The prevalence of apical periodontitis and endodontically treated teeth with AP was high and similar to the results of studies performed in other countries.


O objetivo deste estudo foi investigar a prevalência de Periodontite Apical (PA) e sua associação com dentes tratados endodonticamente em residentes de São Luís, MA, Brasil. Foram selecionadas 200 séries completas de radiografias periapicais de arquivos de quatro protesistas e cinco periodontistas dos últimos 10 anos (1993-2003). O índice Periapical (PAI) foi utilizado e a faixa etária, sexo, grupos dentais, localização de maior prevalência e associação aos dentes com tratamento endodôntico (TE) foram analisados. Os testes Cohen Kappa e qui-quadrado foram utilizados para análise estatística. Dos registros de 200 pacientes, 135 apresentavam algum caso de PA, resultando numa prevalência de 67,5 por cento. Do total de 5008 dentes, 296 tinham PA e 553 tinham TE. Desse modo, a prevalência de PA foi de 5.8 por cento e de TE foi de 11 por cento. Dos 553 casos de dentes tratados endodonticamente, 235 (42.5 por cento) estavam associados com PA. A faixa etária de 40 anos foi significativamente mais prevalente (p<0.05). Não houve associação entre PA e sexo (p>0.05). O grupo dental mais acometido foi dos incisivos superiores (p<0.05). A PA teve predileção pela maxila e apresentou-se fortemente associada com dentes tratados endodonticamente (p<0.05). A prevalência de periodontite apical e de tratamento endodôntico de dentes associado com PA encontrada neste estudo foi alta e está de acordo com resultados de estudos realizados em outros países.


Assuntos
Humanos , Masculino , Feminino , Periodontite Periapical/epidemiologia , Radiografia Dentária , Tratamento do Canal Radicular , Endodontia
13.
J. appl. oral sci ; 14(3): 183-187, May-June 2006. tab
Artigo em Inglês | LILACS, BBO | ID: biblio-873222

RESUMO

O objetivo deste estudo foi investigar a prevalência de Periodontite Apical (PA) e sua associação com dentes tratados endodonticamente em residentes de São Luís, MA, Brasil. Foram selecionadas 200 séries completas de radiografias periapicais de arquivos de quatro protesistas e cinco periodontistas dos últimos 10 anos (1993-2003). O índice Periapical (PAI) foi utilizado e a faixa etária, sexo, grupos dentais, localização de maior prevalência e associação aos dentes com tratamento endodôntico (TE) foram analisados. Os testes Cohen Kappa e qui-quadrado foram utilizados para análise estatística. Dos registros de 200 pacientes, 135 apresentavam algum caso de PA, resultando numa prevalência de 67,5 por cento. Do total de 5008 dentes, 296 tinham PA e 553 tinham TE. Desse modo, a prevalência de PA foi de 5.8 por cento e de TE foi de 11 por cento. Dos 553 casos de dentes tratados endodonticamente, 235 (42.5 por cento) estavam associados com PA. A faixa etária de 40 anos foi significativamente mais prevalente (p<0.05). Não houve associação entre PA e sexo (p>0.05). O grupo dental mais acometido foi dos incisivos superiores (p<0.05). A PA teve predileção pela maxila e apresentou-se fortemente associada com dentes tratados endodonticamente (p<0.05). A prevalência de periodontite apical e de tratamento endodôntico de dentes associado com PA encontrada neste estudo foi alta e está de acordo com resultados de estudos realizados em outros países


Assuntos
Humanos , Masculino , Feminino , Periodontite Periapical/epidemiologia , Radiografia Dentária , Tratamento do Canal Radicular , Endodontia
14.
RGO (Porto Alegre) ; 53(4): 351-355, out.-dez. 2005. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-436253

RESUMO

O objetivo deste trabalho foi analisar comparativamente a resistência à fratura de instrumentos de níquel-titânio acionados a motor, levando-se em consideração a quantidade de voltas que o instrumento realizava antes da fratura verificando, a influência da conicidade, da marca e do calibre dos instrumentos. Foram utilizados duzentos e quarenta instrumentos de níquel-titânio, acionados a motor, com 25mm de comprimento, das marcas Profile (Dentsply/Maillefer - Suíça) e Pow-R (Moyco Union Broach - EUA) nos números 15, 20, 25, 30, 35 e 40, distribuídas nos Grupo I: Pow-R 0.02; Grupo II: Pow-R 0.04; Grupo III: Profile 0.04 e Grupo IV: Profile 0.06. Os instrumentos foram submetidos ao ensaio de torção utilizando um dispositivo que empregava rotação no sentido horário. Esse dispositivo era conectado a uma máquina de ensaios mecânicos (MTS - Material Test System) que permitia determinar a quantidade de voltas de cada lima até ocorrer à fratura. Os valores foram analisados estatisticamente, utilizando um teste paramétrico (Análise de Variância). De um modo geral, para os diferentes números, independentes do grupo a que pertenciam, houve um aumento, em média, do número de voltas com o aumento do calibre do instrumento. Em relação a conicidade dos instrumentos verificou-se uma relação inversa entre esse item e a quantidade de voltas antes da fratura, quando se aumentava a conicidade diminuía a quantidade de voltas. Os instrumentos da marca Pow-R, em geral, foram estatisticamente superiores.


Assuntos
Ciência dos Materiais , Tratamento do Canal Radicular/instrumentação
15.
JBC j. bras. clin. estet. odontol ; 3(18): 82-85, nov. 1999. ilus, graf
Artigo em Português | LILACS, BBO | ID: lil-427716

RESUMO

A proposta deste estudo foi avaliar a eficiência de corte de lima fabricada de níquel-titânio (Nitiflex), comparado-a om limas fabricadas com ligas de aço inoxidável (K-File e Flexofile), nas numerações de 15 a 40. Utilizou-se uma máquina que realizava movimentos cíclicos lineares das lemas sob corpos-de-prova de resina. A avaliação baseou-se na diferença da passagem inicial e final dos corpos-de-prova.Não houve diferença estatística significante da eficiência de corte entre as limas Flexofile e Nitiflex em todos os números avaliados (p<0,5). A eficiência de cortes de lima Flexofile e Nitiflex, nos tamanhos de 15 a 35, foi significativamente maior que as das limas K-File nos memsos números (p>0,5). As limas Flexofile número 40 apresentaram uma tendência ao aumento da eficiência de corte


Assuntos
Instrumentos Odontológicos , Equipamentos Odontológicos , Níquel , Aço Inoxidável , Titânio
16.
JBC j. bras. clin. estet. odontol ; 3(15): 74-77, maio 1999. ilus
Artigo em Português | LILACS, BBO | ID: lil-415768

RESUMO

Tratou-se endodonticamente um dente traumatizado portador de vários sinais clínicos e radiográficos de patologia pulpar e periapical, no qual, após o preparo biomecânico, aplicou-se como medicação tópica entre sessões, "curativo de demora", a pasta Calen/PMCC, pelo período dfe 30 dias, seguido a obturação, coadjuvada com cimento à base de hidróxido de cálcio. A proservação apresentou avançado processo de reparo periapical


Assuntos
Humanos , Masculino , Adulto , Tratamento do Canal Radicular , Hidróxido de Cálcio , Continuidade da Assistência ao Paciente , Necrose da Polpa Dentária , Doenças Periapicais/terapia , Reabsorção da Raiz , Calcificação de Dente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA