PURPOSE: To compare the results between percutaneous bone grafting and open bone grafting of tibial shaft fractures. METHOD: Thirty tibial fractured shafts with a delayed union or a high-energy tibial fractures which required early prophylaxis bone grafts were randomized to either percutaneous bone graft (n= 15) or open bone graft (n=15). One patient from the open bone graft group was lost to follow-up. Characteristics of the patients were similar in both groups. RESULTS: The mean length of follow-up was 2.5 years. Percutaneous bone graft technique was associated with significantly less blood loss (p<0.01) and shorter operative time (p<0.01). One patient in the percutaneous group had posterior tibial nerve palsy postoperatively, which recovered completely after 6 weeks. There were no differences in rate of union, healing time of the successful cases, postoperative pain and hospital stay. CONCLUSION: The percutaneous technique has effective results similar to the open technique in promoting union of tibial fractures. It should be considered as a useful alternative to the open bone graft technique.


Assuntos
Adolescente , Adulto , Idoso , Transplante Ósseo/métodos , Feminino , Consolidação da Fratura , Fraturas não Consolidadas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estatísticas não Paramétricas , Fraturas da Tíbia/diagnóstico por imagem , Resultado do Tratamento