Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Clinics ; 76: e3547, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1350618

RESUMO

OBJECTIVE: Coronavirus disease 2019 (COVID-19) is associated with high mortality among hospitalized patients and incurs high costs. Severe acute respiratory syndrome coronavirus 2 infection can trigger both inflammatory and thrombotic processes, and these complications can lead to a poorer prognosis. This study aimed to evaluate the association and temporal trends of D-dimer and C-reactive protein (CRP) levels with the incidence of venous thromboembolism (VTE), hospital mortality, and costs among inpatients with COVID-19. METHODS: Data were extracted from electronic patient records and laboratory databases. Crude and adjusted associations for age, sex, number of comorbidities, Sequential Organ Failure Assessment score at admission, and D-dimer or CRP logistic regression models were used to evaluate associations. RESULTS: Between March and June 2020, COVID-19 was documented in 3,254 inpatients. The D-dimer level ≥4,000 ng/mL fibrinogen equivalent unit (FEU) mortality odds ratio (OR) was 4.48 (adjusted OR: 1.97). The CRP level ≥220 mg/dL OR for death was 7.73 (adjusted OR: 3.93). The D-dimer level ≥4,000 ng/mL FEU VTE OR was 3.96 (adjusted OR: 3.26). The CRP level ≥220 mg/dL OR for VTE was 2.71 (adjusted OR: 1.92). All these analyses were statistically significant (p<0.001). Stratified hospital costs demonstrated a dose-response pattern. Adjusted D-dimer and CRP levels were associated with higher mortality and doubled hospital costs. In the first week, elevated D-dimer levels predicted VTE occurrence and systemic inflammatory harm, while CRP was a hospital mortality predictor. CONCLUSION: D-dimer and CRP levels were associated with higher hospital mortality and a higher incidence of VTE. D-dimer was more strongly associated with VTE, although its discriminative ability was poor, while CRP was a stronger predictor of hospital mortality. Their use outside the usual indications should not be modified and should be discouraged.


Assuntos
Humanos , Biomarcadores/análise , COVID-19/diagnóstico , COVID-19/terapia , Proteína C-Reativa , Produtos de Degradação da Fibrina e do Fibrinogênio , Receptores Imunológicos/análise , Estudos Prospectivos , SARS-CoV-2
2.
Rev. bras. cardiol. invasiva ; 23(4): 238-241, out.-dez. 2015. tab, graf
Artigo em Português | LILACS | ID: biblio-846502

RESUMO

Introdução: A válvula aórtica transcateter de segunda geração LotusTM foi desenhada para proporcionar ao intervencionista o controle completo de sua liberação durante o procedimento. O presente estudo apresenta a experiência inicial e os desfechos hospitalares de pacientes tratados com essa prótese no Brasil. Métodos: Registro observacional, retrospectivo, que incluiu pacientes com estenose aórtica grave sintomáticos, considerados de alto risco cirúrgico, tratados em sete centros.Resultados: Receberam o dispositivo 31 pacientes, sendo 61,3% do sexo feminino, com idade de 82,9 ± 6,9 anos e escore STS de 6,5 ± 4,1%. A área valvar aórtica foi de 0,73 ± 0,18 cm2 e o gradiente médio de 51,7 ± 13,9 mmHg. Todos os procedimentos foram realizados pela via transfemoral, e a pré-dilatação foi necessária em 65% dos casos. A taxa de sucesso do procedimento foi de 96,7%. Não houve complicação vascular com necessidade de intervenção cirúrgica e nem casos de acidente vascular cerebral. O gradiente médio após o procedimento foi de 10,5 ± 5,8 mmHg e não foram observadas regurgitações aórticas de graus moderado/importante. A taxa de implante de marca-passo definitivo foi de 38,7%, e a permanência hospitalar de 8,5 ± 4,8 dias. Conclusões: Na experiência inicial com o implante da válvula aórtica LotusTM, os resultados hospitalares demostraram a segurança e a eficácia do dispositivo, além de ausência de regurgitação aórtica relevante


Background: The second-generation LotusTM transcatheter aortic valve was designed to provide the interventional cardiologist with complete control of its release during the procedure. This study presents the initial experience and in-hospital outcomes of patients treated with this prosthesis in Brazil. Methods: This observational and retrospective study included patients with symptomatic severe aortic stenosis considered at high surgical risk, treated in seven centers. Results: The device was used in 31 patients, 61.3% female, aged 82.9 ± 6.9 years, and with STS score of 6.5 ± 4.1%. The aortic valve area was 0.73 ± 0.18 cm2 and the mean gradient was 51.7 ± 13.9 mmHg. All procedures were performed by the transfemoral access route, and pre-dilation was necessary in 65% of cases. The success rate of the procedure was 96.7%. There were no vascular complications requiring surgical intervention nor cases of stroke. The mean gradient after the procedure was 10.5 ± 5.8 mmHg; no cases of moderate to severe aortic regurgitation were observed. The rate of permanent pacemaker implantation was 38.7%, and mean in-hospital length of stay was 8.5 ± 4.8 days. Conclusions: In the initial experience with the use of the LotusTM aortic valve, in-hospital results demonstrated the safety and efficacy of the device; no cases of significant aortic regurgitation were observed


Assuntos
Humanos , Masculino , Feminino , Idoso , Valva Aórtica/cirurgia , Próteses e Implantes , Desfibriladores Implantáveis , Estenose da Valva Aórtica/terapia , Bioprótese/tendências , Fatores de Risco , Estudo Observacional , Insuficiência Cardíaca/terapia , Valvas Cardíacas/cirurgia , Ventrículos do Coração/fisiopatologia
3.
Rev. bras. cardiol. invasiva ; 22(4): 315-319, Oct-Dec/2015. tab, graf
Artigo em Português | LILACS, SES-SP | ID: lil-744565

RESUMO

Introdução: Polímeros biodegradáveis foram desenvolvidos para reduzir a reação de hipersensibilidade associada aos polímeros duráveis dos stents farmacológicos de primeira geração, mantendo sua eficácia antiproliferativa e aumentado sua segurança. Avaliamos os resultados angiográficos de 9 meses e os resultados clínicos de longo prazo dos stents farmacológicos com polímeros biodegradáveis em pacientes com alto risco de reestenose. Métodos: Pacientes com diâmetro de referência ≤ 2,5 mm, extensão da lesão ≥ 15 mm, diabetes, ou uma combinação dessas características foram selecionados da população do estudo PAINT. Esses pacientes foram previamente randomizados e alocados para intervenção coronária percutânea recebendo os stents farmacológicos com polímeros biodegradáveis com sirolimus ou com paclitaxel ou stents metálicos, na razão 2:2:1. Resultados: Cento e setenta e oito pacientes foram tratados com stents farmacológicos com polímeros biodegradáveis (n = 142) ou stents metálicos (n = 36). No acompanhamento angiográfico de 9 meses, os primeiros mostraram menor perda tardia (0,40 ± 0,42 mm vs. 0,90 ± 0,47 mm; p < 0,01) e reestenose binária (7,4% vs. 25%; p < 0,01). No acompanhamento clínico de 5 anos, o grupo com stents farmacológicos com polímeros biodegradáveis mostrou menores taxas do desfecho combinado de morte cardíaca, infarto do miocárdio e revascularização do vaso-alvo (16,2% vs. 38,0%; p = 0,03), principalmente devido à redução da revascularização do vaso-alvo (9,9% vs. 36,1%; p < 0,01). Morte total, morte cardíaca e infarto do miocárdio não foram diferentes entre os grupos. A trombose do stent, provável ou definitiva, ocorreu em 2,8% vs. 0% (p = 0,30). Conclusões: Os stents farmacológicos com polímeros biodegradáveis eluidores de paclitaxel ou sirolimus foram eficazes na redução de reestenose angiográfica aos 9 meses e na necessidade de reintervenção por reestenose clínica em 5 anos, sem aumentar o risco de...


Background: Biodegradable polymers were developed to reduce the hypersensitivity reaction associated to durable polymers found with the first generation drug-eluting stents, while maintaining antiproliferative efficacy and increasing safety. This study evaluated the 9-month angiographic follow-up and long-term clinical outcomes of biodegradable polymer-coated drug-eluting stents compared with identical platform metallic stents in patients with high-risk for restenosis. Methods: Patients with a reference diameter ≤ 2.5 mm, lesion length ≥ 15 mm, diabetes, or a combination of these characteristics were selected from the population of the PAINT trial. These patients were previously randomized and allocated for percutaneous coronary intervention with either a sirolimus-eluting biodegradable polymer-coated stent, a paclitaxel-eluting biodegradable polymer-coated stent, or an identical metallic platform stent, at a ratio of 2:2:1. Results: One hundred and seventy-eight patients were treated with biodegradable polymer-coated drug-eluting stents (n = 142) or bare metal stents (n = 36). At the 9-month angiographic follow-up, biodegradable polymercoated drug-eluting stents had lower rates of late loss (0.40 ± 0.42 mm vs. 0.90 ± 0.47 mm; p < 0.01) and binary restenosis (7.4% vs. 25%; p <0.01). In the 5-year clinical follow-up, the group with biodegradable polymer-coated drug-eluting stents had lower rates of the composite endpoint of cardiac death, myocardial infarction, and target vessel revascularization (16.2% vs. 38.0%; p = 0.03), especially due to the reduction of target vessel revascularization (9.9% vs. 36.1%; (p 0.01). Total death, cardiac death and myocardial infarction were not different among groups. 0% (p = 0.30). Conclusions: Paclitaxel or sirolimus-eluting biodegradable polymer-coated stents were effective in reducing angiographic restenosis at 9 months and the need of reintervention for clinical restenosis in 5...


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Angiografia Coronária/métodos , Polímeros/uso terapêutico , Reestenose Coronária/terapia , Stents , Stents Farmacológicos , Trombose Coronária/terapia , Interpretação Estatística de Dados , Medição de Risco/métodos , Paclitaxel/uso terapêutico , Resultado do Tratamento , Sirolimo/uso terapêutico , Vasos Coronários/cirurgia
4.
Rev. bras. cardiol. invasiva ; 21(2): 121-127, abr.-jun. 2013. tab
Artigo em Português | LILACS | ID: lil-681944

RESUMO

INTRODUÇÃO: A prevenção secundária após intervenção coronária percutânea (ICP) é fundamental para melhorar a sobrevida livre de eventos e consiste principalmente no controle de fatores de risco. Analisou-se a prevenção secundária de pacientes de alto risco, incluídos prospectivamente no estudo Sequence Variation in Platelet Aggregation in Response to Clopidogrel and aspirin (SPARC). MÉTODOS: Foram arrolados 187 pacientes consecutivos entre dezembro de 2009 e fevereiro de 2011, tratados por ICP com stent e avaliados em retornos ambulatoriais de 30 dias, 3 meses, 6 meses e 12 meses quanto ao controle de hipertensão arterial, disglicemia, dislipidemia e tabagismo, e medidas terapêuticas respectivas. RESULTADOS: Houve aumento significativo de pacientes com controle pressórico (29%; P = 0,02), que cessaram tabagismo (18%; P = 0,003), e que receberam hipolipemiantes (19%; P < 0,0001) entre a internação para ICP e o primeiro retorno após o procedimento. Esse melhora do controle de fatores de risco refletiu-se em redução do escore de risco de Framingham médio observado no mesmo período (9,9%; P < 0,0001). Durante seguimento de até 12 meses o ganho atingido na internação para ICP se manteve para todos os fatores de risco. CONCLUSÕES: Observou-se efeito importante relativamente à internação índice para ICP, com aumento da prescrição de medicamentos para controle de fatores de risco e alcance de metas. Esse estudo identifica relevante janela de oportunidade para priorização do controle de fatores de risco na internação inicial, quando ganhos expressivos são observados e mantidos. Mas também explicita que esforços adicionais são necessários para expandir o benefício da prevenção secundária no seguimento a médio prazo de pacientes tratados por ICP.


BACKGROUND: Secondary prevention after percutaneous coronary intervention (PCI) is essential to increase event-free survival and consists mainly in risk factor control. We analyzed the secondary prevention of high-risk patients included prospectively in the Sequence Variation in Platelet Aggregation in Response to Clopidogrel and aspirin trial (SPARC). METHODS: From December 2009 to February 2011 we enrolled 187 consecutive patients who were submitted to PCI with stent implantation and were evaluated in outpatient visits at 1, 3, 6, and 12 months of follow-up for the control of hypertension, dysglycemia, hyperlipidemia and smoking and their respective therapeutic measures. RESULTS: There was a significant increa­se in the number of patients with controlled hypertension (29%; P = 0.02), who stopped smoking (18%; P = 0.003), and received statins (19%; P < 0.0001) between the index PCI and the first follow-up visit. The risk factor control improvement led to a decrease in the mean Framingham risk score (9.9%; P < 0.0001). During the 12 months follow-up the gains achieved at PCI admission were maintained for all risk factors. CONCLUSIONS: An important effect was observed on the index PCI admission with increased prescription of risk factor control drugs and achievement of therapeutic goals. This study identifies a relevant opportunity window for risk factor control at the index admission, when substantial gains are observed and maintained. However, it also shows further efforts are required to expand the benefit of secondary prevention in the middle-term follow-up of patients treated by PCI.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Angioplastia/métodos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/prevenção & controle , Stents , Prevenção de Doenças , Fatores de Risco
5.
Arq. bras. cardiol ; 100(1): 29-36, jan. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-662392

RESUMO

FUNDAMENTO: A aspirina (Ácido Acetilsalicílico - AAS) é capaz de reduzir eventos adversos cardiovasculares em pacientes portadores de Doença Arterial Coronariana (DAC) através da inibição da atividade plaquetária. Alguns pacientes com DAC, apesar da terapia com AAS, apresentam Alta Reatividade Plaquetária (ARP), o que determina um maior risco para o desenvolvimento de eventos cardiovasculares. OBJETIVO: O objetivo deste estudo foi determinar a prevalência de ARP em pacientes tratados com AAS e encaminhados para cinecoronariografia, além de avaliar se existe uma possível correlação entre a gravidade da DAC e o desenvolvimento de ARP. MÉTODOS: Estudo de centro único onde foram incluídos 115 pacientes consecutivos, tratados com AAS e portadores de DAC estável. A reatividade plaquetária induzida pelo ADP e colágeno foram avaliadas através da Agregometria de Transmitância Luminosa (ATL). Pacientes com agregação plaquetária maior que 70%, induzida por ambos os reagentes, foram classificados como tendo ARP e, neste grupo, a adesão ao tratamento com AAS foi avaliada através da dosagem dos níveis séricos de salicilato. RESULTADOS: A média de idade foi de 60,9 anos e a dose média de AAS foi de 164,2 mg. Tabagismo e diabetes melito estavam presentes em 28,7% e 31,5% dos pacientes, respectivamente. Foi encontrada ARP em 14 pacientes (13%), entretanto, em sete indivíduos (50%) com ARP observaram-se baixos níveis séricos de salicilato (< 2,0 µg/mL), sugerindo não adesão à terapia medicamentosa. Em 6,5% dos pacientes com ARP identificou-se níveis detectáveis de salicilato sérico, sugerindo uma eficácia reduzida do AAS. A ARP se correlacionou com o número e a gravidade das estenoses coronárias (p = 0,04). CONCLUSÃO: Em uma população de pacientes tratados com AAS e encaminhados para angiografia coronária, a reatividade plaquetária elevada é prevalente (13%), sendo 50% destes pacientes não aderentes à terapia farmacológica e 50% apresentam redução da efetividade da droga.


BACKGROUND: Aspirin (ASA) reduces adverse events in coronary artery disease (CAD) patients by inhibiting platelets. Some CAD patients have high platelet reactivity (HPR) despite ASA therapy and these individuals have increased risk of adverse events. OBJECTIVE: The purpose of this study was to determine the prevalence of HPR in ASA-treated patients referred for coronary angiography and to assess whether the HPR correlates with the severity of CAD. METHODS: This single center investigation enrolled 115 consecutive ASA-treated patients with stable CAD. ADP- and collagen-induced platelet reactivity were evaluated by light transmittance aggregometry (LTA). Patients with greater than 70% ADP- and collagen-induced aggregation were determined to have HPR and, in this group, ASA compliance was assessed by examining blood salicylate levels. Mean age was 60.9 years and average ASA dose was 164.2 mg. RESULTS: Smoking and DM were present in 28.7% and 31.5% respectively. HPR was found in 14 patients (13%) however 7 of the 14 patients (50%) with HPR had low serum salicylate levels (< 2.0 µg/mL) suggesting medication noncompliance. Of the entire cohort, 6.5% of patients had HPR and detectable serum salicylate levels suggesting reduced ASA efficacy. HPR correlated with number and severity of coronary stenosis (p = 0.04). CONCLUSION: In a general population of ASA-treated patients referred for coronary angiography, elevated platelet reactivity is prevalent (13%) with 50% related to noncompliance and 50% related to reduced aspirin efficacy.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aspirina/administração & dosagem , Angiografia Coronária , Doença da Artéria Coronariana/tratamento farmacológico , Inibidores da Agregação Plaquetária/administração & dosagem , Agregação Plaquetária/efeitos dos fármacos , Colágeno/sangue , Doença da Artéria Coronariana/complicações , Resistência a Medicamentos , Fatores de Risco , Salicilatos/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA