Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. bras. cardiol. invasiva ; 16(3): 328-332, jul.-set. 2008. ilus, tab
Artigo em Português | LILACS, SES-SP | ID: lil-503481

RESUMO

Fundamentos: Distúrbios de fluxo coronário decorrentes de embolização de fragmentos de ateroma/trombo estão associados a pior prognóstico após intervenção coronária percutânea (ICP). A abordagem de lesões em pontes de safena (PS) e no cenário de síndromes coronárias agudas (SCA) está frequentemente associadda a essas complicações. Apesar de dispositivos de proteção embólica terem demonstrado seu valor na prevenção desses eventos, estes adicionam tempo e custo à ICP, além de terem seu uso limitado às PS. Recém-desenvolvido, o stent MGuard combina uma malha microscóspica presa às hastes de um stent não-farmacológico, conferindo baixo perfil a esse dispositivo. Objetivos: Avaliar a eficácia e a segurança do stent MGuard por meio de desfechos clínicos e angiográficos. Método: Estudo unicêntrico com 19 pacientes portadores de lesões de novo em PS ou lesões com características angiográficas de instabilidade em coronárias nativas. O desfecho primário inclui a taxa de eventos cardíacos adversos maiores (ECAM) em trinta dias. Resultados: A apresentação clínica em 60 por cento dos casos era de SCA e em 55 por cento dos pacientes a lesão encontrava-se em PS. O stent MGuard foi implantado com sucesso em todos os casos, alcançando fluxo TIMI 3/blush 3 ao final de todas as ICPs, não sendo observadas complicações angiográficas. Não registradas elevações de CK-MB maiores de três vezes o valor de rferência pós-ICP ou ECAM...


Background: Disturbances in coronary flow due to embolization of thrombus/atheroma fragments are associated with poor prognosis after percutaneous coronary intervention (PCI). Lesions in saphenous vein grafts (SVG) and acute coronary syndromes (ACS) are typically associated with these complications. Although embolic protection devices have shown to reduce the incidence of such complications, they add time and costs to the procedure, and their use is limited to SVG. The newly developed MGuard™ stent combines a microscopic net connected to the struts of a bare metal stent, characterizing this new low-profile device. Objective: To evaluate safety and efficacy of the novel MGuard™ stent system through clinical and angiographic outcomes. Methods: Single-center study including 19 patients with de novo lesions in SVG or with unstable lesions in native vessels as evidenced by angiography. Primary end point included 30-day incidence of major adverse cardiac events (MACE). Results: ACS was the clinical presentation in 60% of cases, and in 55% of the patients the lesion was in a SVG. The MGuard™ stent was successfully delivered in all cases, reaching TIMI 3/blush 3 flow at the end of all procedures. There were no cases of angiographic complications, CK-MB elevations > 3x the reference values after PCI, or MACE at 30 day-follow-up. Conclusion: In this preliminary evaluation, the MGuard™ stent showed high efficacy in a group of patients with highly complex angiographic profile (without the use of adjunctive embolic protection devices). Six-month angiographic follow-up and a larger cohort of patients are necessary to corroborate these results.


Assuntos
Humanos , Feminino , Adulto , Idoso , Stents , Ponte de Artéria Coronária/métodos , Segurança de Equipamentos , Aspirina/administração & dosagem , Embolia , Estudos Prospectivos , Estudos de Viabilidade , Ferimentos e Lesões/terapia , Veia Safena/lesões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA