Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
International Eye Science ; (12): 602-606, 2023.
Artigo em Chinês | WPRIM | ID: wpr-965785

RESUMO

Teprotumumab-trbw,a monoclonal antibody that acts on the insulin growth factor-Ⅰ receptor, was approved in 2020 for the treatment of thyroid-associated ophthalmopathy, but little is known about it in China. It is hoped to provide guidance for clinical use through the review of its molecular structure, pharmacokinetics, therapeutic mechanism, clinical research and safety. It inhibits immune inflammation by blocking thyroid-stimulating hormone receptor /insulin growth factor-Ⅰ receptor crosstalk signaling, so as to reduce the production of hyaluronic acid and inflammatory factors in response. It can also promote the apoptosis of retro-orbital fibroblasts/adipocytes and inhibit the expression of genes related to the synthesis of thyroid hormones, thereby significantly improving the clinical symptoms such as exophthalmos and diplopia. The common adverse reactions of Teprotumumab-trbw are muscle spasm, hyperglycemia, hearing loss and so on. Teprotumumab-trbw is effective and durable in the treatment of thyroid-associated ophthalmopathy, and patients with secondary treatment can also benefit from it, which provides a new way and hope for the treatment of thyroid-associated ophthalmopathy.

2.
Chinese Journal of Preventive Medicine ; (12): 1047-1058, 2023.
Artigo em Chinês | WPRIM | ID: wpr-985515

RESUMO

Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.


Assuntos
Gravidez , Criança , Humanos , Feminino , Hemoglobinas Glicadas , Estudos de Coortes , Diabetes Mellitus/diagnóstico , Sensibilidade e Especificidade , Curva ROC
3.
International Eye Science ; (12): 1137-1142, 2022.
Artigo em Chinês | WPRIM | ID: wpr-929494

RESUMO

Thyroid-associated ophthalmopathy(TAO)is an organ-specific autoimmune disease, which will cause a series of symptoms to significantly reduce the health level and life quality of patients. The pathogenesis of TAO has not been fully clarified. At present, there is a lack of unified and mature treatment scheme of it. Indeed, T-helper 17 lymphocyte(Th17)cells, regulatory T(Treg)cells and their imbalance are closely related to the immunological pathogenesis of TAO. It is currently believed that the cytokines secreted by Th17 cells can not only promote the inflammatory response of TAO and the fibrosis of orbital connective tissue, but also inhibit the adipogenic differentiation of TAO orbital connective tissue. In addition, Treg cells mainly exert immunosuppressive effect on TAO and delay the disease progression. At the same time, there is a dynamic balance relationship between Th17 and Treg cells, the imbalance of Th17/Treg cells can trigger the occurrence and development of TAO. This paper mainly expounds the influence mechanism of Th17, Treg cells and their balance on TAO, and analyzes the reasons for the differences between different research results, so as to provide some reference for the study of the pathogenesis and clinical treatment of TAO.

4.
Journal of Zhejiang University. Medical sciences ; (6): 546-560, 2004.
Artigo em Chinês | WPRIM | ID: wpr-353263

RESUMO

<p><b>OBJECTIVE</b>To assess health-related quality of life in hemodialysis patients and to identify related socio-demographic and clinical variables.</p><p><b>METHODS</b>By a cluster sampling procedure, 181 hemodialysis patients from 4 hemodialysis centers in Hangzhou completed the SF-36 Scales with self-administration. The means and deviations for each of eight scales were calculated, the results in the samples were compared with those in general population. Univariate analysis and multivariate regression were applied to determine the effect of variables such as age, gender, educational level, employment status,marital status, income,sleep, hemodialysis history, hemoglobin, co-existing diseases and so forth, on quality of life in the patients.</p><p><b>RESULTS</b>The scores of the eight scales in the hemodialysis patients were 57.7 +/-18.2, 6.1 +/-16.6, 63.2 +/-17.4, 27.2 +/-12.9, 31.1 +/-17.0, 41.6 +/-14.6, 58.0 +/-45.2 and 65.3 +/-15.5. Except MH, the scores of all the scale in the patients were significantly lower than those in general population. In the multiple linear stepwise regression model of Physical Component Summary,the seven variables of age, sleep, hemoglobin, skeletal-muscle diseases, married status, diabetes mellitus and cardiopathy were included (P<0.01), while in that of Mental Component Summary, the three variables of age, sleep and hemoglobin were included (P<0.01).</p><p><b>CONCLUSION</b>The quality of life in hemodialysis patients is impaired. Greater attention should be given to interventions that could improve quality of life.</p>


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falência Renal Crônica , Terapêutica , Qualidade de Vida , Análise de Regressão , Diálise Renal , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA