Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Veterinary Science ; : 209-214, 2011.
Artigo em Inglês | WPRIM | ID: wpr-108032

RESUMO

Due primarily to the increasing shortage of allogeneic donor organs, xenotransplantation has become the focus of a growing field of research. Currently, micropigs are the most suitable donor animal for humans. However, no standard method has been developed to evaluate the systemic vascular anatomy of micropigs and standard reference values to aid in the selection of normal healthy animals as potential organ donors are lacking. Using 64-channel multidetector row computed tomographic angiography (MDCTA), we evaluated morphological features of the major systemic vessels in micropigs and compared our results to published human data. The main vasculature of the animals was similar to that of humans, except for the iliac arterial system. However, diameters of the major systemic vessels were significantly different between micropigs and humans. Specifically, the diameter of the aortic arch, abdominal aorta, external iliac artery, and femoral artery, were measured as 1.50 +/- 0.07 cm, 0.85 +/- 0.06 cm, 0.52 +/- 0.05 cm, and 0.48 +/- 0.05 cm, respectively, in the micropigs. This MDCTA data for micropig major systemic vessels can be used as standard reference values for xenotransplantation studies. The use of 64-channel MDCTA enables accurate evaluation of the major systemic vasculature in micropigs.


Assuntos
Animais , Humanos , Masculino , Aorta/anatomia & histologia , Aortografia/veterinária , Artéria Femoral/anatomia & histologia , Artéria Ilíaca/anatomia & histologia , Valores de Referência , Suínos , Porco Miniatura/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Transplante Heterólogo
2.
Journal of Veterinary Science ; : 185-189, 2010.
Artigo em Inglês | WPRIM | ID: wpr-115098

RESUMO

Micropigs are the most likely source animals for xenotransplantation. However, an appropriate method for evaluating the lung of micropigs had not been established. Therefore, this study was performed to evaluate the feasibility of 64-channel multi-detector row computed tomography (MDCT) to measure the diameter of the pulmonary arteries and the lung volume in micropigs. The mean diameters of the trachea, and left and right bronchi were 1.6 +/- 0.17, 1.18 +/- 0.14, and 1.1 +/- 0.11 cm, respectively. The mean diameters of the main, right, and left pulmonary arteries were 1.38 +/- 0.09, 1.07 +/- 0.26, and 0.98 +/- 0.13 cm and the diameters of right, left, and common inferior pulmonary veins were 0.97 +/- 0.20, 0.76 +/- 0.20, and 1.99 +/- 0.26 cm, respectively. The mean lung volume was 820.3 +/- 77.11 mL. The data presented in this study suggest that the MDCT may be a noninvasive, rapid, and accurate investigational method for pulmonary anatomy in living lung donors.


Assuntos
Animais , Humanos , Pulmão/fisiologia , Tamanho do Órgão/fisiologia , Artéria Pulmonar/fisiologia , Suínos , Porco Miniatura/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Transplante Heterólogo/métodos
3.
Journal of Veterinary Science ; : 9-13, 2010.
Artigo em Inglês | WPRIM | ID: wpr-160879

RESUMO

Multidetector row computed tomography (MDCT) provides anatomical information about the kidney and other internal organs. Presently, the suitability of 64-channel MDCT to assess the kidney of healthy micropigs was evaluated. Morphological evaluations of the kidney and the major renal vessels of six healthy micropigs were carried out using MDCT, recording kidney volume and the diameter and length of renal arteries and veins. The mean diameters and lengths of the renal artery were 0.44 +/- 0.05 and 4.51 +/- 0.55 cm on the right side and 0.46 +/- 0.06 and 3.36 +/- 0.27 cm on the left side, respectively. The mean diameters and lengths of the renal vein were 1.44 +/- 0.52 and 4.22 +/- 1.29 cm on the right side and 1.38 +/- 0.17 and 5.15 +/- 0.87 cm on the left side, respectively. The mean volume of the right kidney was 79.3 +/- 14.5 mL and of the left kidney was 78.0 +/- 13.9 mL. The data presented in this study suggest that the MDCT offers a noninvasive, rapid, and accurate method for the evaluation of the renal anatomy in living kidney donors. It also provides sufficient information about extra-renal anatomy important for donor surgery and determination of organ suitability.


Assuntos
Animais , Masculino , Rim/anatomia & histologia , Transplante de Rim/métodos , Artéria Renal/anatomia & histologia , Veias Renais/anatomia & histologia , Suínos , Porco Miniatura/anatomia & histologia , Obtenção de Tecidos e Órgãos/métodos , Tomografia Computadorizada por Raios X/métodos
4.
Journal of Veterinary Science ; : 93-98, 2009.
Artigo em Inglês | WPRIM | ID: wpr-221149

RESUMO

The shortage of organ donors has stimulated interest in the possibility of using animal organs for transplantation into humans. In addition, pigs are now considered to be the most likely source animals for human xenotransplantation because of their advantages over non-human primates. However, the appropriate standard values for estimations of the liver of micropigs have not been established. The determination of standard values for the micropig liver using multi-detector row computed tomography (MDCT) would help to select a suitable donor for an individual patient, determine the condition of the liver of the micropigs and help predict patient prognosis. Therefore, we determined the standard values for the livers of micropigs using MDCT. The liver parenchyma showed homogenous enhancement and had no space-occupying lesions. The total and right lobe volumes of the liver were 698.57 +/- 47.81 ml and 420.14 +/- 26.70 ml, which are 51.74% and 49.35% of the human liver volume, respectively. In micropigs, the percentage of liver volume to body weight was approximately 2.05%. The diameters of the common hepatic artery and proper hepatic artery were 6.24 +/- 0.20 mm and 4.68 +/- 0.13 mm, respectively. The hepatic vascular system of the micropigs was similar to that of humans, except for the variation in the length of the proper hepatic artery. In addition, the diameter of the portal vein was 11.27 +/- 0.38 mm. In conclusion, imaging evaluation using the MDCT was a reliable method for liver evaluation and its vascular anatomy for xenotransplantation using micropigs.


Assuntos
Animais , Feminino , Humanos , Masculino , Artéria Hepática/anatomia & histologia , Imageamento Tridimensional/métodos , Fígado/anatomia & histologia , Transplante de Fígado/métodos , Doadores Vivos , Veia Porta/anatomia & histologia , Suínos , Porco Miniatura/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Transplante Heterólogo/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA