Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Medical Instrumentation ; (6): 368-369, 2010.
Artigo em Chinês | WPRIM | ID: wpr-281081

RESUMO

During the routine tests, it's found that the testing method related to Hemodialysis mentioned in the industry standard YY0598-2006 cannot reflect the real bicarbonate concentration in Hemodialysis. To discuss the reaction principle and its interference factors deeply by studying the assay determination of bicarbonate in Hemodialysis, and it could be cited as reference for amending the quality standard or troubleshooting. The improved way of determining bicarbonate concentration in Hemodialysis is also put up.


Assuntos
Bicarbonatos , Soluções para Diálise , Padrões de Referência , Diálise Renal , Métodos , Padrões de Referência
2.
Chinese Journal of Ultrasonography ; (12): 354-357, 2009.
Artigo em Chinês | WPRIM | ID: wpr-395273

RESUMO

Objective To prepare phospholipid-based sulfur hexafluoride gas-filled microbubbles, which were designed for targeting microbubbles. Methods The microbubbles composed of DSPC and mPEG2000-PE were produced by film-sonication method,and were compared with SonoVue. In the physical chemistry characteristics studies, the morphology, particle diameter, concentration, pH value and osmotic pressure were investigated. In the echogenicity studies, contrast harmonic imaging technique was used to investigate the enhancement of vitro water sac and normal rabbit kidney parenchyma. Results The lipid microbubbles were well-distributed, round with air holes. The average diameter of self-made microbubbles and SonoVue were 2.25 μm and 2.50μm respectively. The average diameter of self-made microbubbles and SonoVue distributed from 0.4 μm to 10 μm and 0.2 μm to 10 μm,and 90% were under 6 μm and 8 μm respectively,the concentration were 5 x 108~10 x 108/ml and 1 x I08~5 x 108/ml respectively with a stability of 6 hours. In vitro water sac, the gray scale of self-made lipid microbubbles and SonoVue were 121.67±6.76 and 122.33 ± 4.53 respectively( P>0.05). In normal rabbit kidney parenchyma, the peak video intensity of normal rabbit kidney parenchyma of self-made lipid microbubbles and SonoVue were 72.00 ± 7.21 and 74. 65± 10.93 respectively(P>0.05). Conclusions The lipid microbubbles have satisfactory physical chemistry characteristics and echogenicity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA