Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Chinese Journal of Medical Instrumentation ; (6): 244-245, 2018.
Artigo em Chinês | WPRIM | ID: wpr-689821

RESUMO

The disposable photophobic infusion was used to simulate clinical infusion under different conditions. The simulated liquid was collected every 30 min (total 4 h),and detected the additives (Fe, MDA and antioxidant 1076) in simulated liquid by spectroscopic method and chromatography method. The method is simple and stable, and can be used for the technical monitoring of the disposable photophobic infusion set in the future.


Assuntos
Equipamentos Descartáveis , Processos Fotoquímicos
2.
Chinese Journal of Medical Instrumentation ; (6): 451-453, 2015.
Artigo em Chinês | WPRIM | ID: wpr-265592

RESUMO

To established an effective GC-MS /MS method for the contents determination of the residual DEHP in injection equipment, and investigate the effect of the pretreatment on the measurement. To simulate the clinical conditions of use, under the condition of 37 degrees C balance extraction, extract liquor by chloroform extraction, then the extract followed by analysis of GC-MS /MS. The method was simple, rapid, sensitive and accurate. The limits of quantitation (LOQ, S/N = 5) of cyclohexanone was 0.075 μg/mL, The spiked average recoveries ranged from 92% to 98%. The relative standard deviations (RSDs) of the method ranged from 1.01% to 1.61%, The method was simple, fast, sensitive and accurate, and may serve as a mass control method for residual DEHP in injection equipment.


Assuntos
Cicloexanonas , Química , Dietilexilftalato , Química , Contaminação de Equipamentos , Cromatografia Gasosa-Espectrometria de Massas , Injeções , Limite de Detecção , Plastificantes , Química
3.
Chinese Journal of Medical Instrumentation ; (6): 381-385, 2014.
Artigo em Chinês | WPRIM | ID: wpr-310318

RESUMO

An effective GC method was established for contents determination of the residual solvent of cyclohexanone in infusion sets for single use. The cyclohexanone in infusion sets for single use products were extracted with circular pump, using ethylalcohol as the extraction solven, then the extract followed by analysis of gas chromatography-tandem mass spectrometry. The method was simple, rapid, sensitive and accurate, Cyclohexanone showed good linearity in the range of (5.5-190.9) μg/mL, the correlation coefficient was 0.999 0, the detection limit (S/N = 3) was 0.133 μg/mL and limits of quantitation (S/N = 10) was 1.33 μg/mL. The spiked average recoveries ranged from 98% to 99%. The relative standard deviations (RSDs) of the method ranged from 1.03% to 1.98%. The method was simple, fast, sensitive and accurate, and may serve as a mass control method for residual cyclohexanone in disposable infusion sets for single use.


Assuntos
Cicloexanonas , Equipamentos Descartáveis , Padrões de Referência , Cromatografia Gasosa-Espectrometria de Massas , Solventes
4.
Chinese Journal of Medical Instrumentation ; (6): 373-374, 2012.
Artigo em Chinês | WPRIM | ID: wpr-342924

RESUMO

Analyzed the purity of the Perfluorooctane used for Ophthalmic operation using the FID (Flame Ionization Detector) method after the qualitative analysis of that. Research and discussion of the 1--hydrogen perfluorocarbon octane, which is the typical impurity of Perfluorooctane. The standard recovery of the 1--hydrogen perfluorocarbon octane is 93%-97% within the range of linearity, and the RSD (relative standard deviation) is below 2%. The above test method has the advantages of easy operation, stability and accuracy. So it is a good reference support to bring the specification of quality control of the Perfluorooctane which is used for Ophthalmic operation into YY of medical device.


Assuntos
Fluorocarbonos , Química , Oftalmologia , Métodos , Controle de Qualidade
5.
Chinese Journal of Practical Nursing ; (36): 19-21, 2010.
Artigo em Chinês | WPRIM | ID: wpr-387507

RESUMO

Objective To investigate changes in cardiac markers and its effect on instructing nursing of patients with acute coronary syndrome(ACS).Methods 100 ACS patients from cardiology department and CCU were randomly divided into the observation group and the control group. The control group was given routine care. the observation group was given intervention according to positive results of cardiac markers. Some indexes such as B-type natriuretic peptide, myoglobin, creatine kinase isoenzyme, cardiac troponin I, and EKG, congestive heart failure and cardiogenic shock as well as appraisal of patients and relatives to nurses were compared between the two groups. Results The observation group was better than the control group in subsequent indicators: B-type natriuretic peptide, myoglobin, creatine kinase isoenzyme, cardiac troponin I,EKG, congestive heart failure and cardiogenic shock, and appraisal of patients and relatives to nurses was also better than the control group. Conclusions Detection of cardiac markers not only has significance for diagnosis, risk stratification and prognosis of ACS, but also help to instruct nursing of ACS patients. It has an important role in raising the nurses ability to identify risk factors and take effective measures to reduce complications and mortality, improve satisfaction degree of patients and their family members.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA