Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
São Paulo med. j ; 132(2): 97-104, 2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-705381

RESUMO

CONTEXT AND OBJECTIVE: The thickness of the carotid intima-media complex (C-IMC) is considered to be a marker of early atherosclerosis, but visual and echogenic changes to the C-IMC can also be noted. The objective here was to evaluate the relationship between cardiovascular risk factors and the echogenicity of the C-IMC and identify those most associated with an "abnormal" C-IMC. DESIGN AND SETTING: Cross-sectional study in the ultrasound sector of the Department of Diagnostic Imaging, Universidade Federal de São Paulo. METHODS: Eighty men were evaluated. Measurements of arterial blood pressure, waist circumference (WC), lipid profile, fasting glucose, uric acid and high-sensitivity C-reactive protein were obtained. The thickness of the C-IMC was measured by means of B-mode ultrasound, and the intima-media gray-scale mean (IM-GSM) and standard deviation (IM-SD) were calculated. RESULTS: The following were discriminating variables: fasting glucose (r2 = 0.036; P = 0.013), uric acid (r2 = 0.08; P = 0.03), IM-SD (r2 = 0.43; P < 0.001), IM-GSM (r2 = 0.35; P < 0.001) and thickness of the C-IMC (r2 = 0.29; P < 0.001). IM-GSM showed significant correlations with WC (r = -0.22; P = 0.005), fasting glucose (r = -0.24; P = 0.002) and high-density lipoprotein cholesterol (HDL-C) (r = 0.27; P = 0.0007). CONCLUSION: IM-GSM showed correlations with WC, fasting glucose and HDL-C. However, uric acid and IM-SD presented the greatest discriminating impact. These results suggest that visual changes in C-IMC may help identify patients with potential cardiovascular risk, independently of the thickness of the C-IMC. .


CONTEXTO E OBJETIVO: A espessura do complexo íntima-média carotídeo (CIM-C) é considerada um marcador da aterosclerose precoce, mas alterações visuais e da ecogenicidade do CIM-C também podem ser observadas. O objetivo foi avaliar a relação entre os fatores de risco cardiovascular e a ecogenicidade do CIM-C e identificar aqueles mais relacionados com o CIM-C "alterado". TIPO DE ESTUDO E LOCAL: Estudo transversal no setor de ultrassonografia do Departamento de Diagnóstico por Imagem, Universidade Federal de São Paulo. MÉTODOS: Oitenta homens foram avaliados. Aferição da pressão arterial, medida da circunferência abdominal (CA), perfil lipídico, glicemia de jejum (GLI), ácido úrico (AU) e proteína C-reativa de alta sensibilidade foram obtidos. A espessura do CIM-C foi medida por ultrassom modo B e a média da escala de cinza (GSM) e do desvio padrão do CIM (DPIM) foram calculados. RESULTADOS: As variáveis discriminantes foram GLI (r2 = 0,036; P = 0,013), AU (r2 = 0,08; P = 0,03), DPIM (r2 = 0,43; P < 0,001), GSM (r2 = 0,35; P < 0,001) e espessura do CIM-C (r2 = 0.29; P < 0,001). Houve correlação significativa entre GSM e CA (r = -0,22; P = 0,005), GLI (r = -0,24; P = 0,002) e lipoproteína de alta densidade do colesterol (HDL-C) (r = 0,27; P = 0,0007). CONCLUSÃO: A GSM teve correlação com CA, GLI, HDL-C. Entretanto, AU e DPIM apresentaram maior impacto discriminante, sugerindo que alterações visuais do CIM-C, independentemente da espessura, podem auxiliar na identificação de pacientes com potencial risco cardiovascular. .


Assuntos
Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Cardiovasculares , Artéria Carótida Primitiva , Espessura Intima-Media Carotídea , Síndrome Metabólica , Aterosclerose/fisiopatologia , Aterosclerose , Proteína C-Reativa/análise , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/fisiopatologia , Artéria Carótida Primitiva/fisiopatologia , Estudos Transversais , Jejum/sangue , Glucose/metabolismo , Lipoproteínas HDL/sangue , Síndrome Metabólica/fisiopatologia , Valores de Referência , Medição de Risco , Fatores de Risco , Ácido Úrico/sangue , Circunferência da Cintura
3.
J. vasc. bras ; 11(1): 83-87, -mar. 2012. ilus
Artigo em Português | LILACS | ID: lil-623436

RESUMO

A ultrassonografia Doppler deixou de ter seu uso apenas como método diagnóstico e vem galgando espaço nos procedimentos terapêuticos. Com maior aplicabilidade e uso de cateteres venosos centrais e procedimentos guiados por ultrassom, há preocupação com a melhora da eficácia e segurança durante o procedimento, assim como com a diminuição das potenciais complicações. Para isso, o treinamento da técnica em modelos (phantoms) é desejável. Os modelos industrializados para treinamento em acesso vascular guiado por ultrassom são caros e não reproduzem adequadamente a ecotextura e a densidade dos tecidos humanos. Na tentativa de treinar e aprimorar os profissionais para o uso do ultrassom em procedimentos de acessos vasculares, desenvolveu-se um modelo animal de baixo custo, fácil confecção e excelente aplicabilidade.


Duplex ultrasonography has not been used only as a noninvasive diagnostic method. Recently it has been applied for therapeutic procedures. Due to the increasing use and applicability of central venous catheters and eco-guided vascular procedures, there are concerns about improving results regarding accuracy and safety, reducing complication rates during those procedures. It would be desirable that training was accomplished using phantoms before actual procedures in human subjects. Industrialized phantoms are expensive and they do not reproduce human's ecographic density and texture. In order to train and improve ultrasound guided vascular access, we have developed a cheap animal tissue model, which is of easy preparation and applicability.


Assuntos
Animais , Modelos Animais , Procedimentos Cirúrgicos Operatórios/métodos , Ultrassonografia Doppler/métodos
4.
J. vasc. bras ; 9(4): 257-260, dez. 2010. ilus
Artigo em Português | LILACS | ID: lil-578806

RESUMO

A escleroterapia com microespuma vem sendo utilizada amplamente no tratamento da doença venosa varicosa. No entanto, a despeito da sua pouca invasividade e segurança, complicações potencialmente graves e letais já foram descritas, como o acidente vascular cerebral e parada cardiorrespiratória. Descrevemos um caso de embolia atrial tardia de trombo flutuante da junção safeno-femoral de veia safena magna varicosa, após escleroterapia com microespuma de polidocanol guiada por ultrassom, e o tratamento dessa complicação.


Microfoam sclerotherapy has been widely used in the treatment of varicose vein disease. However, despite its low invasiveness and safety, potentially serious and lethal complications have been described, such as stroke and cardiorespiratory arrest. We describe a case of delayed atrial embolism of floating thrombus in the saphenofemoral junction of a great saphenous varicose vein after microfoam ultrasound-guided sclerotherapy, as well as the treatment of this complication.


Assuntos
Humanos , Masculino , Embolia/diagnóstico , Escleroterapia/enfermagem , Tromboembolia Venosa , Veia Safena/anormalidades , Ultrassonografia
5.
J. vasc. bras ; 9(1): 4-13, 2010. tab
Artigo em Português | LILACS | ID: lil-557195

RESUMO

A eventual relação entre a aterosclerose das artérias dos membros inferiores com a aterosclerose das artérias intestinais foi pouco estudada. Objetivo: Avaliar pela ecografia vascular (Doppler) presença de lesões com estenose 70 por cento na artéria mesentérica superior e/ou tronco celíaco em doentes com arteriopatia obstrutiva crônica dos membros inferiores. Método: Foram estudados dois grupos, cada um com 60 doentes (40 homens e 20 mulheres). O grupo-caso foi composto por doentes com arteriopatia obstrutiva crônica dos membros inferiores, claudicação intermitente limitante ou dor de repouso e/ou lesões tróficas de extremidade, sem queixas gastrintestinais...


Assuntos
Humanos , Masculino , Feminino , Artéria Celíaca/patologia , Artéria Mesentérica Inferior , Arteriopatias Oclusivas/diagnóstico , Aterosclerose/diagnóstico , Extremidade Inferior , Isquemia Miocárdica/complicações , Ecocardiografia Doppler/enfermagem , Prevalência
6.
J. vasc. bras ; 7(4): 316-320, dez. 2008. tab
Artigo em Inglês, Português | LILACS | ID: lil-506106

RESUMO

CONTEXTO: A disponibilidade de acesso venoso nos pacientes que recebem cursos prolongados de terapia citotóxica é de grande importância para o sucesso do tratamento. Os cateteres totalmente implantáveis vêm sendo cada vez mais utilizados para a referida terapia, proporcionando melhoria na qualidade de vida dos doentes. OBJETIVO: Avaliar a perviedade e complicações dos cateteres venosos totalmente implantáveis instalados nos pacientes oncológicos. MÉTODOS: Estudo longitudinal retrospectivo com 74 pacientes submetidos a colocação de cateter totalmente implantável de janeiro de 2004 a fevereiro de 2007. RESULTADOS: Foram inseridos cateteres venosos totalmente implantáveis em 74 pacientes com idade média 48,9 anos, predominando o sexo feminino. As neoplasias mais prevalentes foram mama (40,5 por cento), cólon (20,8 por cento) e linfoma (18,9 por cento). Houve predomínio do acesso venoso pela via cervical (74,3 por cento), com utilização da veia jugular interna em 45,9 por cento dos casos. Somente 13,5 por cento dos acessos ocorreram por punção da veia subclávia. A duração média de uso dos cateteres foi de 335,33 dias. Trinta e seis doentes (48,6 por cento) mantiveram-se com o cateter após o término da quimioterapia. Sessenta e sete doentes (90,5 por cento) não apresentaram complicações. Entre as complicações precoces, houve um (1,4 por cento) pneumotórax e um (1,4 por cento) hematoma na loja de implantação. Entre as complicações tardias, ocorreram cinco (6,7 por cento) infecções. Foram retirados 10 (13,5 por cento) cateteres, cinco devido às complicações e cinco por término do tratamento. Houve 11 (14,9 por cento) óbitos de pacientes em decorrência do câncer, com o cateter funcionante. CONCLUSÃO: Os resultados obtidos demonstram baixa taxa de complicações, confirmando a segurança e conveniência do uso dos acessos totalmente implantáveis em paciente em regime de quimioterapia.


BACKGROUND: Availability of venous access for patients that receive long-term cytotoxic therapy is of great importance to the success of treatment. Totally implantable devices have been increasingly more used for this therapy, providing improvement in the quality of life of patients. OBJECTIVE: To evaluate patency and complications of totally implantable catheters inserted in oncological patients. METHODS: Retrospective longitudinal study of 74 patients that underwent placement of totally implantable catheter from January 2004 throughout February 2007. RESULTS: Totally implantable catheters were placed in 74 patients with mean age of 48.9 years; the female gender was predominant. The most prevalent neoplasms were breast (40.5 percent), colon (20.8 percent) and lymphoma (18.9 percent). Cervical access (74.3 percent) was prevalent, using the internal jugular vein in 45.9 percent of cases. Only 13.5 percent of accesses were inserted via subclavian vein puncture. Mean duration of catheter use was 335.33 days. Thirty six (48.6 percent) patients remained with the catheter after the chemotherapy was discontinued. There were no complications in 67 (90.5 percent) patients. Among early complications, there was one (1.4 percent) pneumothorax and one (1.4 percent) hematoma. Among late complications, there were five (6.7 percent) infections. Ten (13.5 percent) catheters were removed, five due complications and five after ending the treatment. Eleven (14.9 percent) patients died from cancer, and the catheters were still functioning. CONCLUSION: The outcomes obtained show low rate of complications, confirming that use of totally implantable catheters is safe and effective for patients undergoing chemotherapy.


Assuntos
Humanos , Masculino , Feminino , Qualidade de Vida , Tratamento Farmacológico/instrumentação , Tratamento Farmacológico/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA