Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Singapore medical journal ; : 48-51, 2019.
Artigo em Inglês | WPRIM | ID: wpr-777561

RESUMO

INTRODUCTION@#The pathophysiology and mechanism of in-stent restenosis (ISR) after implantation of second-generation drug-eluting stents (DESs) are not fully clear. We compared the morphological characteristics of ISR between first- and second-generation DESs using frequency domain optical coherence tomography (OCT).@*METHODS@#Patients who underwent follow-up coronary angiography (CAG) after first-generation (CYPHER™ and TAXUS™) and second-generation (Nobori®, PROMUS Element™, Resolute Integrity and XIENCE) DES implantations were examined. ISR was defined as lesions of over 50% diameter stenosis at follow-up CAG. Frequency domain OCT was performed at the time of revascularisation of ISR. Tissue morphology was assessed at minimum lumen area. OCT images of DESs at both early (≤ 1 year) and late (> 1 year) phase follow-up were compared.@*RESULTS@#On qualitative OCT assessment, the ratios of homogeneous, layered, heterogeneous without-attenuation and heterogeneous with-attenuation morphologies were 57.1%, 17.1%, 20.0% and 5.7%, respectively, for second-generation DES ISR (n = 35), and 16.7%, 25.0%, 25.0% and 33.3%, respectively, for first-generation DES ISR (n = 36). At late phase follow-up, homogeneous morphology was significantly more common for second-generation DES ISR compared to first-generation DES ISR (first-generation: 8.0% vs. second-generation: 50.0%; p < 0.01) while heterogeneous with-attenuation morphology was significantly more common for first-generation DES ISR (first-generation: 44.0% vs. second-generation: 5.6%; p < 0.01).@*CONCLUSION@#Homogeneous tissue morphology was more frequently found for second-generation than first-generation DES ISR, especially in the late phase. This suggested that neointimal hyperplasia was the main mechanism in second-generation DES ISR, and that the neointima was stabilised, much like in bare metal stent implantation.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Constrição Patológica , Patologia , Angiografia Coronária , Reestenose Coronária , Diagnóstico por Imagem , Patologia , Vasos Coronários , Diagnóstico por Imagem , Patologia , Cirurgia Geral , Stents Farmacológicos , Incidência , Metais , Neointima , Estudos Retrospectivos , Tomografia de Coerência Óptica
2.
The Korean Journal of Internal Medicine ; : 1-12, 2012.
Artigo em Inglês | WPRIM | ID: wpr-148191

RESUMO

Optical coherence tomography (OCT) is an optical analog of intravascular ultrasound (IVUS) that can be used to examine the coronary arteries and has 10-fold higher resolution than IVUS. Based on polarization properties, OCT can differentiate tissue characteristics (fibrous, calcified, or lipid-rich plaque) and identify thin-cap fibroatheroma. Because of the strong attenuation of light by blood, OCT systems required the removal of blood during OCT examinations. A recently developed frequency-domain OCT system has a faster frame rate and pullback speed, making the OCT procedure more user-friendly and not requiring proximal balloon occlusion. During percutaneous coronary intervention (PCI), OCT can provide detailed information (dissection, tissue prolapse, thrombi, and incomplete stent apposition [ISA]). At follow-up examinations after stent implantation, stent strut coverage and ISA can be assessed. Several OCT studies have demonstrated delayed neointimal coverage following drug-eluting stent (DES) implantation vs. bare metal stent (BMS) placement. While newer DESs promote more favorable vascular healing, the clinical implications remain unknown. Recent OCT studies have provided insights into restenotic tissue characteristics; DES restenotic morphologies differ from those with BMSs. OCT is a novel, promising imaging modality; with more in-depth assessments of its use, it may impact clinical outcomes in patients with symptomatic coronary artery disease.


Assuntos
Humanos , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Reestenose Coronária/etiologia , Vasos Coronários/patologia , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Stents , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA