Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Korean Journal of Blood Transfusion ; : 198-203, 2011.
Artigo em Coreano | WPRIM | ID: wpr-9043

RESUMO

BACKGROUND: Proficiency testing is part of a total quality management program that provides objective evidence of clinical laboratory testing competence for customers, accrediting bodies, and regulatory agencies. Performing alternative assessment procedures for clinical tests, without proficiency testing, is recommended by Clinical and Laboratory Standards Institute (CLSI) guideline. In our study, an alternative assessment procedure was performed for blood bank tests that do not have an external proficiency program. METHODS: The laboratory for development and an evaluation center, supervised the program. Proficiency testing by seven institutions was performed 3 times at 6 month intervals by evaluating isoagglutinin and anti-D titers, and Weak D, Rh C and E typing, using ID-Internal Quality Control (Bio-Rad Laboratories) kits. RESULTS: Isoagglutinin and anti-D titer results were within one fold dilution range for all seven participating institutions, and Weak D, Rh C and E typing results all demonstrated identical antigenic reference patterns. CONCLUSION: An alternative assessment procedure was successfully performed without a proficiency testing program. Commercially manufactured reference materials could be an alternative method to support commutable, external, proficiency testing program.


Assuntos
Bancos de Sangue , Isoanticorpos , Competência Mental , Controle de Qualidade , Gestão da Qualidade Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA