Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Mem. Inst. Oswaldo Cruz ; 88(2): 263-9, abr.-jun. 1993.
Artigo em Inglês | LILACS, SES-SP | ID: lil-119487

RESUMO

Antibodies of IgG and IgM isotopes reacting with Plasmodium falciparum and P. vivax thick-smear antigens were searched for by the indirect fluorescent antibody test (IFAT) in a random sample of 230 blood donors at the transfusion centre of Porto Velho (HEMERON), Rondônia State, western Brazilian Amazon. A high prevalence of IgG seropositivity (32% against P. falciparum, 24% against P. vivax and 37% against either P. falciparum or P. vivax antigens) was detected among them, despite the fact that candidates reporting recent (<12 months) malaria attacks were not elegible. Only a small proportion of them had also detectable IgM antibodies to these antigens. These data suggest an intense, relatively recent exposure to malaria in such an urban population sample. However, parasitaemia (as detected by microscopical examination of Giemsa-stained thick smears) was patent in only one prospective donor. The antibody profile of blood donors was compared with that of healthy subjects of all age groups, living in a close endemic area (Candeias village, 21 km east of Porto Velho). The villagers were classified into two groups according to their history of a recent (<12 months) or a remote (>12 months) past malaria attack due to either P. falciparum or P. vivax. Extensive overlapping was observed when the distribution of antibody titres of healthy subjects from Candeias village with a recent and remote malaria history was compared. In conclusion, subjects with a recent or a remote malaria history could not be distinguished by sorological criteria alone


Assuntos
Plasmodium falciparum , Plasmodium vivax , Doadores de Sangue , Malária , Brasil
2.
Mem. Inst. Oswaldo Cruz ; 87(2): 205-8, abr.-jun. 1992. ilus
Artigo em Inglês | LILACS, SES-SP | ID: lil-116306

RESUMO

Blood sampling on filter paper is a current practice seroepidemiological studies by indirect fluorescent antibody test (IFAT). There is, however, scant comparative information about the use of bloodspot eluates for detection of malarial IgG antibodies simultaneously by IFAT and enzyme immunoassay (ELISA). Here we report data obtained by both serological methods done on 219 bloodspot eluate samples collected in a rural community in Brazilian Amazon Basin (Alto Paraíso, Ariquemes municipality) where malaria is endemic. Plasmodium falciparum and P. vivax thick smear antigens were used in the IFAT; a detergent-soluble P. falciparum antigen was prepared for ELISA. Substantial agreement of results (Kappa coefficient k = 0.686) was observed when P. falciparum antigen was used in both tests, and IFAT titers were found to be strongly correlated ELISA antibody units (Spearman correlation coeficient rs = 0.818, p < 0.0001).


Assuntos
Animais , Plasmodium falciparum/imunologia , Plasmodium vivax/imunologia , Ensaio de Imunoadsorção Enzimática/instrumentação , Testes Sorológicos , Malária/diagnóstico , Imunofluorescência/instrumentação , Brasil
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA